D_PD.pdf

PDF 126 KB Posted

Attached to
Cytek Aurora Flow Cytometry System Federal contract opportunity
Solicitation number
75N95022Q00168
Issued by
Department of Health and Human Services National Institutes of Health National Institute on Drug Abuse

About this file

This document includes a purchase description and related federal contract opportunity solicitation. The purchase description seeks a Flow Cytometry System to replace an existing flow cytometer for the Viral Immunology Section of the National Institute of Neurological Disorders and Stroke. The system requirements include a laser with multiple channels, automated sample loader, trade-in of an existing system, and APD assay. Delivery is required within 30 days of order receipt.

The related federal contract opportunity is a request for quotation issued by the Department of Health and Human Services National Institutes of Health National Institute on Drug Abuse. It seeks a Cytek Aurora Flow Cytometry System meeting the specifications in the attached purchase description. Quotes are due by June 1, 2022. Evaluation will consider technical capability, price, and past performance. The successful offeror must provide the requested system within the delivery time stated in the purchase description after receipt of order.

View the file

Other files for this federal contract opportunity

Other files attached to Cytek Aurora Flow Cytometry System, newest first.
File Type Posted
D_FAR 52.212-5 Jan 2022.pdf PDF
D_FAR 52.204-24 Nov 2021.pdf PDF
D_FAR 52.204-26 Oct 2020.pdf PDF
D_FAR 52.212-4 Addendum.pdf PDF
D_Invoice Instructions.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PURCHASE DESCRIPTION

1. Statement of Need and Purpose: This acquisition is necessary to provide the Viral Immunology Section (VIS) with a Flow Cytometry System to replace an existing LSRII (Becton Dickinson) flow cytometer that has been used in the Neuroimmunology Branch and the VIS. The LSRII is no longer under warranty and can no longer be serviced.

2. Background Information and Objective: The LSRII flow cytometer has been the reliable and unique machine used for our flow cytometric research for the past fifteen (15) years and vital to the collaborative work done in the National Institute of Neurological Disorders and Stroke (NINDS) clinical laboratories. All clinical studies within VIS; including natural history and interventional studies, use the LSRII to phenotypically characterize lymphocyte populations from blood and Cerebrospinal fluid (CSF) of patients with chronic neurologic disease and controls, over the course of illness and in response to experimental therapies.

The replacement of the LSRII with a Flow Cytometry System will allow VIS and the entire branch to continue to accomplish all present and future goals and plans.

3. Generic Name of Product: Flow Cytometry System.

4. Purchase Description:

Item Description Quantity

Flow Cytometry Laser: UV/V/B/YG/R (64 + 3 Channel) 1.00 Automated Sample Loader 1.00 Trade-in : BD FACS Aria SORP SN# P69500110 1.00 APD Assy, Violet 16 Channel with Small Particle Enhanced Performance (V-SPE) 1.00 40 tube rack 2.0 1.00 SpectroFlo Software License 1.00

5. Salient characteristics. All deliverables required under this contract shall be packaged, marked and shipped in accordance with Government specifications. At a minimum, all deliverables shall be marked with the contract number and Contractor name. The Contractor shall guarantee that all required materials shall be delivered in immediate usable and acceptable condition.

Vendor must be able to provide these specifications:

a) Small footprint system containing a paradigm-shifting optical design that provides unprecedented flexibility, enabling the use of a wide array of new fluorochrome combinations without reconfiguring our system for each application.

b) Optics and state-of-the-art low-noise electronics with excellent sensitivity and resolution.

c) Flat-Top beam profiles, combined with a uniquely designed, vacuum-based fluidic system, translate to outstanding performance at high sample flow rates.

d) Ability to deliver high quality data, and easily resolve rare and dim populations, regardless of assay complexity and all will contribute to ease-of use, and reproducibility of data.

e) Transfer of existing data to the new Flow Cytometry System

6. Delivery Date: Thirty (30) days after receipt of the purchase order.