This technical drawing detail sheet, created by the Emerald Coast Utilities Authority (ECUA), specifies the design and technical requirements for a standard manhole frame and cover for sanitary sewer infrastructure. The document, dated September 1, 2016, provides precise dimensional specifications and manufacturing guidelines for a Type 2 non-penetrating pick slot manhole cover, indicating it is part of a municipal infrastructure procurement process.
The technical specifications mandate that the manhole frame and cover must be manufactured by U.S. Foundry (USF170E model), constructed of cast iron conforming to ASTM Specification A-48, Class 30, with specific dimensional requirements. The design includes unique features such as a non-venting cover, except in specific scenarios involving force mains, drop mains, or auxiliary release valves (ARV). The document provides detailed cross-sectional views and measurements, including a 24-inch overall diameter, with specific tolerances for frame depth, slot dimensions, and structural components, suggesting a precise engineering standard for municipal infrastructure components.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Manhole Lid and Cover Specification.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MANHOLE FRAME & COVER
DATE: 9/01/2016
D-11N.T.S.SCALE:
DETAIL
AutoCAD SHX Text
SECTION A - A
AutoCAD SHX Text 3 1/4"
AutoCAD SHX Text 3/8"
AutoCAD SHX Text 1"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 2 1/4"
AutoCAD SHX Text 22 1/2"
AutoCAD SHX Text 24 1/2"
AutoCAD SHX Text 30 1/4"
AutoCAD SHX Text 5/8"
AutoCAD SHX Text
SANITARY
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text 24"
AutoCAD SHX Text 23 3/4"
AutoCAD SHX Text 9/16"
AutoCAD SHX Text 9"
AutoCAD SHX Text 1 1/4"
AutoCAD SHX Text 6"
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
NON-PENETRATING
AutoCAD SHX Text
PICK SLOT (TYPE 2)
AutoCAD SHX Text
1. FRAME AND COVER SHALL BE U.S. FOUNDRY USF170E, BOLTING
AutoCAD SHX Text
FEATURES NOT REQUIRED.
AutoCAD SHX Text
3. MANHOLE COVER IS TO BE NON-VENTING, EXCEPT WHEN USED ON A RECEIVING MANHOLE
AutoCAD SHX Text
FOR A FORCE MAIN, A MANHOLE THAT HAS A DROP MAIN OR LATERAL ENTERING IT, OR A
AutoCAD SHX Text
MANHOLE THAT HOUSES AN ARV (SEE DETAIL D-31).
AutoCAD SHX Text
2. FRAME AND COVER SHALL CONFORM TO ASTM SPEC. A-48, CLASS 30 CAST IRON.