Item No 1: 753731-G-0480-B-1-C-065-A-23-J-2-M-2002
Description: Model K-Bar 2000B-HT KBAR Length: 57.6 Inches
F1 (G) Rectangular Stack/Duct, Full Span, External End Support F2 (0480) Stack Duct Flow Dimension (D) = 48.0 inches F3 (B) Remote Electronics Enclosure. Model 196-4B Electronics Encl. and Model 190-4B Junction Box.
Includes two S.S. I.D. Tags F4 (1) Type 1, One Segment K-BAR and SFTIW Segment F5 (C) Two 4-20 mA Isolated Outputs, two solid-state relays, two digital inputs, one non-isolated 4-20 mA Input.
F6 (065) Flange To Inside Wall Length (FTIW) = 6.5 inches, W1 = .125" F7 (A) Standard Temperature Compensation (STC) over process temperature range of -40°C to +125°C F8 (23) Two Sensor(s)/Alloy C-276 / FD2 HT, U1 = 12.0", U2 = 36.0" F9 (J) 2" Raised Face Class 150 ANSI B16.5 Mounting Flange F10 (2) 316L Stainless Steel Flange Material F11 (M) 6000 SFPM (28 NMPS) Calibration Data Range F12 (2002) K-BAR Segment 1 is 316L SS Tube/ 316L SS Windows and FTIW is 316L Stainless Steel, L1 = 51.1" with 2 Sensor(s), W2 = 0.1" Flow Elements for Combustion Air on Units 1, 3, and 4 TAGS: LC-FE-1CAF; LC-FE-3CAF; LC-FE-4CAF Replacements for KBAR S/N: 885A, 870C, 870D Qty: 3
| Item No 2: | 750993-A-10-A |
| Description: | Model: 255A |
F1 (A) Polycarbonate Enclosure, General Industrial Safety. Conforms to UL STD 61010-1, 61010-2-030.
Certified to CSA STD C22.2 No.61010-1, 61010-2-030 F2 (10) Two 4-20 mA Isolated Outputs, two solid-state Relays, two digital inputs, one non-isolated 4-20 mA input F3 (A) Stainless steel window kit option is not applicable for PC/Rack Mount enclosures Flow Transmitters for Combustion Air on Units 1, 3,and 4
TAGS: LC-FT-1CAF; LC-FT-3CAF; LC-FT-4CAF
Replacements for 155 S/N: 8136; 8068; 8069 Area: 12.56637 ft²
AO1: 0 - 6,000 SFPM
AO2: 0 - 400° F
Qty: 3
Item No 3: 753732-B-0210-B-1-C-063-D-23-J-2-M-2002
Description: Model K-Bar 2000B-HHT KBAR Length: 21.6 Inches
F1 (B) Round Stack/Duct, Full Span, Single-End Support F2 (0154) Stack Duct Flow Dimension (D) = 21.0 inches F3 (B) Remote Electronics Enclosure. Model 196-4B Electronics Encl. and Model 190-4B Junction Box.
Includes two S.S. I.D. Tags F4 (1) Type 1, One Segment K-BAR and SFTIW Segment F5 (C) Two 4-20 mA Isolated Outputs, two solid-state relays, two digital inputs, one non-isolated 4-20 mA Input.
F6 (063) Flange To Inside Wall Length (FTIW) = 6.3 inches, W1 = 0.3" F7 (D) Velocity/Temperature/Mapping (VTM) with data sets over process temperature range 0°C up to +500°C F8 (23) Two Sensor(s)/Alloy C-276 / FD2 HHT, U1 = 2.4", U2 = 13.3" F9 (J) 2" Raised Face Class 150 ANSI B16.5 Mounting Flange F10 (2) 316L Stainless Steel Flange Material F11 (M) 6000 SFPM (28 NMPS) Calibration Data Range F12 (2002) K-BAR Segment 1 is 316L SS Tube/ 316L SS Windows and FTIW is 316L Stainless Steel, L1 = 15.3" with 2 Sensor(s) Flow Elements for FGR on Units 1, 3, and 4
TAGS: LC-FE-1RFG; LC-FE-3RFG; LC-FE-4RFG
Replacements for KBAR S/N: 854A; 854C; 854D
Qty: 3
Item No 4: 750993-A-10-A
Description: Model 255A up to 4 channels
F1 (A) Polycarbonate Enclosure, General Industrial Safety. Conforms to UL STD 61010-1, 61010-2-030.
Certified to CSA STD C22.2 No.61010-1, 61010-2-030 F2 (10) Two 4-20 mA Isolated Outputs, two solid-state Relays, two digital inputs, one non-isolated 4-20 mA input F3 (A) Stainless steel window kit option is not applicable for PC/Rack Mount enclosures Flow Transmitters for FGR on Units 1, 3, and 4
TAGS: LC-FT-1RFG; LC-FT-3RFG; LC-FT-4RFG
Replacements for FGR portion of 155 S/N: 8028, 8030, 8031 Area: 1.293507 ft² Range: 0 - 12,000 PPH
Qty: 3
Item No 5: 753732-B-0356-A-1-C-0124-D-23-J-2-M-2002
Description: Model K-Bar 2000B-HHT KBAR Length: 45.3 Inches
F1 (B) Round Stack/Duct, Full Span, Single-End Support F2 (0356) Stack Duct Flow Dimension (D) = 35.6 inches F3 (A) Directly Attached Electronics Enclosure for up to four sensors Model 196-4B. Includes one S.S. I.D.
Tag F4 (1) Type 1, One Segment K-BAR and SFTIW Segment F5 (C) Two 4-20 mA Isolated Outputs, two solid-state relays, two digital inputs, one non-isolated 4-20 mA Input.
F6 (0124) Flange To Inside Wall Length (FTIW) = 12.4 inches, W1 = 0.3125" F7 (D) Velocity/Temperature/Mapping (VTM) with data sets over process temperature range 0°C up to +500°C F8 (23) Two Sensor(s)/Alloy C-276 / FD2 HHT, U1 = 5.2", U2 = 30.4" F9 (J) 2" Raised Face Class 150 ANSI B16.5 Mounting Flange F10 (2) 316L Stainless Steel Flange Material F11 (M) 6000 SFPM (28 NMPS) Calibration Data Range F12 (2002) K-BAR Segment 1 is 316L SS Tube/ 316L SS Windows and FTIW is 316L Stainless Steel, L1 = 32.9" with 2 Sensor(s) Flow Elements for Stack on Units 1, 3, and 4
TAGS: LC-FE-1ST; LC-FE-3ST; LC-FE-4ST
Replacements for KBAR S/N: 855A, 855C, 855D
Qty: 3
Item No 6: 750993-A-10-A
Description: Model 255A up to 4 channels
F1 (A) Polycarbonate Enclosure, General Industrial Safet²y. Conforms to UL STD 61010-1, 61010-2-030. Certified to CSA STD C22.2 No.61010-1, 61010-2-030 F2 (10) Two 4-20 mA Isolated Outputs, two solid-state Relays, two digital inputs, one non-isolated 4-20 mA input F3 (A) Stainless steel window kit option is not applicable for PC/Rack Mount enclosures Flow Transmitters for Stack on Units 1, 3, and 4
TAGS: LC-FT-1ST; LC-FT-3ST; LC-FT-4ST
Replacements for Stack portion of 155 S/N: 8028, 8030, 8031 Area: 6.912377 ft² Range: 0 - 80,000 PPH
Qty: 3
File details come from the government source that posted it. Updated .