B08_ATCH_1_SALIENTS_7014015_weather_7-7-23.pdf

PDF 174 KB Posted

Attached to
MULTI-PARAMETER WEATHER TRANSMITTER IAW SALIENTS Federal contract opportunity
Solicitation number
140G0123Q0215
Issued by
Department of the Interior US Geological Survey Office of Acquisitions and Grants

About this file

This document outlines salient characteristics and specifications for a federal solicitation seeking multi-parameter weather transmitters. The United States Geological Survey Hydrologic Instrumentation Facility requires all-in-one units that can measure at least six parameters including wind speed and direction, liquid precipitation, barometric pressure, air temperature, relative humidity. Units shall contain no moving parts, include a USB connection and IP65 rating, operate from -50 to 60 degrees C on external 12VDC, and include a 25ft connection cable. Acceptable models include the WXT536 or equal.

Related solicitation 140G0123Q0215 from the Department of Interior USGS Office of Acquisitions and Grants seeks these multi-parameter weather transmitters per the provided salient characteristics.

View the file

Other files for this federal contract opportunity

Other files attached to MULTI-PARAMETER WEATHER TRANSMITTER IAW SALIENTS, newest first.
File Type Posted
Sol_140G0123Q0215.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

Weather Transmitter

The USGS Hydrologic Instrumentation Facility needs to purchase weather transmitters. This equipment will be used for measuring weather data (including rainfall, barometric pressure, air temperature, and humidity at various sites all over the country.

Shall:

Consist of an all-in-one unit that measures at least six parameters including:

Wind speed and direction, liquid precipitation, barometric pressure, air temperature, relative humidity Contain no moving parts Include a USB connection Include an Ingress Protection (IP) rating of at least 65 Include an SDI-12 interface Have an operating temperature range of at least -50 to 60 degrees C Operate from external 12 VDC Include a connection cable of at least 25 feet

Model WXT536; part no. 6A1B1A3B1A1B OR EQUAL