Salient Characteristics S22093

FIVE-BEAM CURRENT PROFILING SYSTEM

Salient Characteristics

2 ea. Five-Beam Current Profiling System:

1. Shall consist of a multi-purpose, self-contained, broadband, five-beam, 1 MHz Acoustic Doppler Current Profiling (ADCP) system.

2. Shall be capable of performing average current measurements.

3. Shall have features that allow the device to be upgradable, as needed, to include echosounder and wave measurement capabilities.

4. Shall have a sampling frequency of at least 16 Hz.

5. Shall have a water velocity profiling range capability up to at least 25 m.

6. Shall be capable of 200 – 256 water velocity measurement cells.

7. Shall have a water velocity range from 1.0 m/s to at least 5.0 m/s.

8. Shall have water velocity measurement accuracy of 1% of measured value +/-0.5 cm/s, or better.

9. Shall have a velocity resolution of 0.1 cm/s, or better.

10. Minimum blanking distance shall be no more than 0.1 m.

11. Shall include built-in temperature, compass, tilt, and pressure sensors.

12. Pressure sensor shall have a range of at least 0-50 m with an accuracy of 0.1% full scale, or better.

13. Shall include at least 16 GB of data storage capability.

14. Shall include a standard sized housing with room for an internal battery.

15. Shall be capable of operating from external 12–48 VDC input.

16. Shall be capable of operating over a temperature range from at least -4 to 40o C.

17. Shall include Ethernet communication capability and applicable interface port.

18. Shall include a power port for external power input.

19. Shall include a 8-pin and 6-pin male connector bulkhead that supports serial, Ethernet, and trigger communications/functionality.

20. Shall include a compatible Ethernet interface cable that is at least 10 m in length with underwater electrical connector and an RJ45 connector.

21. Shall include a compatible 10 m serial cable with serial connector and RS485 trigger.

Additional Accessories:

22. Each unit shall include a compatible 50 m power/serial communication cable with open ended leads on one end and an underwater 8p SubConn connector on the other end.