Attachment B - Technical Requirements Checklist.xlsx
XLSX spreadsheet 12 KB Posted
- Attached to
- Rapid Max Nitrogen Analyzer Federal contract opportunity
- Solicitation number
- TTB-40200-23-0009
About this file
This document contains a technical requirements checklist for a rapid max nitrogen analyzer system solicitation. The solicitation from the Department of the Treasury Bureau of the Fiscal Service seeks offers for a compact benchtop nitrogen analyzer that uses the Dumas combustion method. Key requirements for the analyzer include a single power supply, automated sample introduction mechanism, 1200 degree Celsius furnace with 10 year warranty, thermal conductivity detector, Windows operating system compatibility, and nitrogen analysis time of five minutes or less. Offerors are to indicate whether their rapid max nitrogen analyzer meets each of the specified 26 technical requirements and specifications listed in the attached checklist table.
Additional details sought include an instrument installation and onsite training for operations and maintenance. The solicitation number is TTB-40200-23-0009 and is for a rapid max nitrogen analyzer.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ-TTB-40200-23-0009-1.pdf | ||
| Attachment A - Product Details.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1 Attachment B - Technical Requirements Checklist
RFQ-TTB-40200-23-0009
| Technical Specifications and Requirements for Acceptance | |
| Offerors Name: Government Scientific Source, Inc. | For Acceptability |
(Place an X in the block)
| OVERVIEW OF RAPID MAX NITROGEN ANALYZER SYSTEM: | Yes | No | |
| Analyzer for measurement of nitrogen or protein according to the Dumas combustion method | |||
| 1 | Compact benchtop instrument with single power supply | ||
| 2 | Automated Sample introduction mechanism | ||
| 3 | A furnace system with 10 year warranty | ||
| 4 | High Sensitivity thermal conductivity detector (TCD) | ||
| 5 | Be controlled by an external PC | ||
| 6 | Sample Introduction mechanism specifications: | ||
| 7 | Fully electrical movement control | ||
| 8 | At least 50 positions sample rack | ||
| 9 | Sample container that accommodates reusable steel or ceramic crucibles holding up to 5g or 5 ml | ||
| 10 | Ability to handle liquid samples | ||
| 11 | Furnace Specifications: | ||
| 12 | Furnace Resistive heater element with 1200 °C maximum temperature | ||
| 13 | Automatic power output adjustment | ||
| 14 | Automatic ash removal | ||
| 15 | No need for cooling down during routine maintenance | ||
| 16 | Argon or helium carrier gas | ||
| 17 | OTHER REQUIRED FEATURES | ||
| 18 | Water removal with condenser, gas membrane and chemical fine drying | ||
| 19 | Purge & trap gas separation technology | ||
| 20 | Two columns with 100% recovery rate | ||
| 21 | Detection limit of 200 ppm (parts per million) or less | ||
| 22 | Analysis time of 5 mins or less | ||
| 23 | Windows® 10, Windows® 8, Windows® 7, or minimum XP, Operating systems | ||
| 24 | Appropriate analyzer software | ||
| 25 | Instrument installation and onsite operations and maintenance training | ||
| 26 | More extended online training |