Attachment A - Salient Characteristics.pdf

PDF 134 KB Posted

Attached to
7H20--Interventional Application Platform Federal contract opportunity
Solicitation number
36C24821Q1029
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

This solicitation seeks quotes for an interventional application platform. The Department of Veterans Affairs C.W. Bill Young VA Healthcare System requires four each of the following: an interventional applications platform with CPU base, power supply, connections box, mouse, keyboard, monitor, DICOM network connection and Windows 10 OS; end user license agreement; imaging license including digital, rotational and chromaFlo IVUS; touch screen module; iFR hyperemia free lesion assessment modality; FFR modality; remote series; five year limited warranty; and five year tech maximizer. Quotes are also requested to provide trade-in credit for two S5ix systems and two CORE systems. Responses are due no later than June 9, 2021. The solicitation number is 36C24821Q1029 and is set aside for service-disabled veteran owned small businesses. The NAICS code is 334290.

View the file

Other files for this federal contract opportunity

Other files attached to 7H20--Interventional Application Platform, newest first.
File Type Posted
36C24821Q1029.docx DOCX document
Attachment C - Clauses.pdf PDF
Attachment B - Price Schedule.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment A

Interventional Application Platform C. W. Bill Young VA Medical Center

Bay Pines, FL 33744

Referenced Manufacturer & Brand Name: Philips Intrasight 5 (P/N: IS5‐WTM5) (Brand Name or Equal)

Salient Characteristics

Equal Items must meet the specific details listed below. Explanation of how Equal Items meet each of the specific details listed below must be included with quote.

Equipment Requirement:

Must have the following characteristics below:

1. QTY. 4: Interventional Applications Platform

CPU on 1 CPU Base

Power Transformer

Cable Pre‐Install Kit

Power Supply

Connections Box

Mouse and Keyboard

19” Monitor kit

DICOM Network Connection and Windows 10 OS

Operator’s Manual

2. QTY. 4: End User License Agreement

3. QTY. 4: Imaging (IVUS) License

Must include: Digital, Rotational and ChromaFlo, IVUS

4. QTY. 4: Touch Screen Module

5. QTY. 4: iFR Hyperemia Free Lesion Assessment Modality

6. QTY. 4: FFR Modality

7. QTY. 4: Remote Series

8. QTY. 4: Five (5) Year Limited Warranty

9. QTY. 4: Five (5) Year Tech Maximizer (Non‐Obsolescence)

10. Must be able to provide trade‐in credit for the following equipment:

Attachment A

QTY. 2: S5ix Systems o S/N: 102120761001 o S/N: 102120760001

QTY. 2: CORE Systems o S/N: 202 o S/N: 203