Attachment 2 Statement of Work.pdf

PDF 800 KB Posted

Attached to
SSMG Refurbishment Federal contract opportunity
Solicitation number
N4215824QS046
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This document is a Statement of Work (SOW) for the repair of a 300kW Ship Service Motor Generator (SSMG) set on a U.S. Navy submarine. The SOW details the contractor responsibilities, which include disassembling the SSMG, resurfacing the commutator and slip rings, replacing bearings and filters, and reassembling the SSMG. The government responsibilities include providing security clearances, work authorizations, and temporary services to support the work. The period of performance is between August 15 and October 15, 2024. The contractor must have the required security clearances and comply with OSHA and NNSY safety requirements. The SOW references several technical manuals and standards that must be followed. Upon completion, the contractor must provide objective quality evidence and assist with operational testing of the SSMG.

View the file

Other files for this federal contract opportunity

Other files attached to SSMG Refurbishment, newest first.
File Type Posted
Attachment 1 FAR 52.212-1 Addendum .pdf PDF
Attachment 3 Combined Synopsis and Solicitation.pdf PDF
Attachment 4 NNSY OPSEC Requirements.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CUI

1 OF 10 CUI

29 JULY 2024

STATEMENT OF WORK

FOR

Repair MTS 616 (S5W) Class 300kW Ship Service Motor Generator (SSMG) Set

Prepared by

NORFOLK NAVAL SHIPYARD

Controlled by: Norfolk Naval Shipyard CUI Category: CTI Distribution Dissemination: FEDCON

Controlled by: NNSY/C275 POC: Bill Herron (843) 794-5096, william.a.herron.civ@us.navy.mil

2 OF 10 CUI

CONTENTS

Section/Para

1 Scope

2 Period of Performance

3 Applicable documents

4 Contractor Responsibilities

5 NNSY Responsibilities

6 Ship’s Force Responsibilities

7 Security Requirements

8 Safety

9 Place of Performance

10 Defense Biometric Identification Systems (DBIDS) for Installation Access

11 Portable Electronic Devices

12 Authorization of Additional Work

13 NNSY Points of Contact

3 OF 10 CUI

1. SCOPE:

Resurface the Port 300kW SSMG commutator to restore bar to bar variance, bar edge burning, Total Indicated Runout (TIR) measurements and verify Electrical Neutral Plane to a satisfactory condition. Resurface the AC Slip Rings and perform an Industrial Clean of the Port SSMG. Upon completion of repairs, perform a successful seasoning run.

2. PERIOD OF PERFORMANCE:

The period of performance will be sometime between 8/15/2024 and 10/15/2024. Services shall occur during these dates as coordinated between the Government POC and the Vendor, however, the actual schedule cannot affect or cause change to the cost or scope of this contract without prior approval of the Contracting Officer.

3. APPLICABLE DOCUMENTS:

3.1. NAVSEA Technical Manual (TM) S9310-AL-MMA-010 –Rev E- Operation, Installation and Maintenance Instructions for SSMG Set

3.2. TM S9310-AC-HBK-010 – Rev 6 – Commutator/Slip Ring Maintenance Handbook

3.3. NAVSEA TM S9086-KC-STM-010/CH300, Chapter 300 – Electric Plant General

3.4. OPNAVINST 4790.4F, Ship’s Maintenance and Material System Policy

3.5. Submarine Maintenance Standard (SMS) 3140-081-044 Rev B, Chg 1 –Restore 300KW SSMG Set Rotors

3.6. Submarine Maintenance Standard (SMS) 3140-081-039 Rev C, Chg 10 –Clean, Inspect, and Re-condition (Classic)

SSMG Set

3.7. SMS 7650-081-003 Rev “D”, Chg 8 – Submarine Inspection and Verification (I and V) Attributes

3.8. Local Work Template 042-014 – Norfolk Naval Shipyard (NNSY) Work Authorization Form (WAF) Requirements.

3.9. FY-24 STANDARD ITEMS

4. CONTRACTOR RESPONSIBILITIES:

4.1. Contractor will provide all Technical Work Documents utilized in performance of this work to Norfolk Naval

Shipyard (NNSY) Engineering Code 275 and Code 246 for review and approval at least five (5) days prior to start of work. Contractor will provide Work Authorization Forms in accordance with Reference (3.8) to NNSY Code 246 prior to start of work.

4.2. Contractor personnel shall have the required security clearances to work areas of Nuclear Power Training Unit

(NPTU) and onboard a US Navy Submarine.

4.2.1. At a minimum, all personnel providing services related to this order shall be United States citizens and shall possess a Department of Defense final-adjudicated Personal Security Clearance at the secret level, in accordance with DD Form 254 for performance on this Task Order. Failure of ability of a worker or supervisor to obtain a

NNSY badge (i.e. minimum final secret clearance) will be cause for NNSY to refuse acceptance of individual.

4 OF 10 CUI

4.2.2. Contractors shall have DBIDS credentials for access to Norfolk Naval Shipyard. Contractors and any subcontractors shall submit contract DD-254 to Norfolk Naval Shipyard Security Department Code 1120 for access requirement verification prior to arrival.

4.2.3. Contractors/subcontractors shall submit Visit Requests via the Joint Personnel Adjudication System (JPAS) to

SMO 39040 for visitor clearance verification. Visit requests submitted by other means will not be accepted without Facility Security Officer signed verification as to the level of security clearance granted to each employee on the visit request.

4.3. Contractor shall attend project provided orientation / training brief that will discuss expected actions of all contractors in the event of a casualty or other emergency situation. Additionally, the Contractor will follow direction of NNSY

Project Team and Ship’s Force in the event of drills or actual emergencies. This orientation is required for each awarded Task Order. Submit a report to the WIL listing all personnel who have attended the orientation. The report shall be submitted prior to personnel coming to the work site. It is Contractor’s responsibility to ensure all personnel that will be working at the job site attend this orientation / training.

4.4. All Contractor work will be conducted in accordance with References (3.1) through (3.6).

4.5. Contractor to provide all tools necessary to support contractor assigned work.

4.6. All trade litter will be removed when contractor breaks for lunch and at the end of each shift. The contractor’s assigned work areas are to remain in a clean and orderly condition. Contractor will remove all industrial material at completion of work operation. Industrial material and other contractor equipment will remain in the designated shipboard and pier side areas.

4.7. Per FAR 22.102-1(a) entitled “Safety,” Contractors are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard cognizance must follow Federal and State OSHA requirements and

Norfolk Naval Shipyard OSHE Program Manual, NAVSHIPYDNORINST P5090.2 requirements or safety requirements for site specific location of the contract.

4.8. Contractor shall accomplish the following specific tasks on the Port SSMG in accordance with References (3.1) through (3.6):

4.8.1. Before performing any shipboard work, Contractor must interface with C246, sign the Letter of Understanding, and follow the work authorization process outlined in Appendix A – Local Work Template 042-014, Norfolk Naval Shipyard (NNSY) Work Authorization Form (WAF), Reference (3.8).

4.8.2. Prior to performing work obtain initial insulation resistance (IR) checks in accordance with References (3.1 and 3.6).

4.8.3. Disassemble Port SSMG AC End in accordance with Reference (3.1 and 3.5) as required to make repairs.

4.8.4. Replace the AC end Slip Rings in accordance with Reference (3.1, 3.2 and 3.5). See paragraph 7.4.

4.8.5. Resurface, polish and/or stone AC end Slip Rings and perform total indicator runout (TIR) in accordance with Reference (3.1, 3.2 and 3.5).

5 OF 10 CUI

4.8.6. Replace, sand and seat new AC brushes in accordance with References (3.1, 3.2 and 3.5).

4.8.6.1. . New brushes to be provided by Ship’s Force.

4.8.7. Stone /Polish Commutator in accordance with References (3.1, 3.2 and 3.5).

4.8.8. Undercut and bevel commutator if necessary, in accordance with References (3.1, 3.2 and 3.5).

4.8.9. Complete SSMG set disassembly as required to gain access for complete inspection of all machine components in accordance with Reference (3.1).

4.8.10. Accomplish in-place detergent/ water cleaning and drying of SSMG Set per Reference (3.3 and 3.6) step 1.f.

NOTE: Reference 3.6 is for 500kw SSMG, however the procedure for performing an in place washing and drying is not Class specific.

4.8.11. Measure bearing seat dimensions.

4.8.12. Replace AC and DC bearing from GFM supplied by Ship’s Force. See paragraph 7.4.

4.8.13. Replace AC and DC overspeed brushes from GFM supplied by Ship’s Force. See paragraph 7.4.

4.8.14. Replace Air Filters from GFM supplied by Ship’s Force. See paragraph 7.4.

4.8.15. Repair/ Replace stripped fasteners and repair threaded bolt holes as required. If required, supplied by Ship’s Force. See paragraph 7.4.8.

4.8.16. Bolted electrical connections disturbed during MG work are to be torqued IAW References (3.1), (3.2) and (3.3) as required.

4.8.17. Replace defective/ disturbed Belleville washers. If required, supplied by Ship’s Force. See paragraph 7.4.8 per References (3.1) and (3.2) as required.

4.8.18. Replace defective access cover gaskets. If required, supplied by Ship’s Force. See paragraph 7.4.8 per References (3.1) and (3.2) as required

4.8.19. Reassemble SSMG set, install and seat new brushes, set neutral plane, accomplish close-out inspection and assist with operational test.

4.8.20. Reassemble Port SSMG in accordance with Reference (3.1) as required to make repairs.

4.8.21. Upon completion obtain final electrical readings in accordance with Reference (3.1 and 3.3).

4.8.22. Contractor shall provide Objective Quality Evidence (OQE) certifying document to NNSY C275 and C246 upon no longer than two (2) days after machine reassembly. OQE must be reviewed and approved by NNSY C275 and C246 prior to start of testing. Certifying document to include, at a minimum, work completed, components replaced, initial and final IR checks, final slip ring TIR measurements and final slip ring diameters.

4.8.23. Paragraph 1.k.(1)- Reassembly complete and Satisfactory.

4.9. Provide test documents to C246 for review and acceptance based on the repairs accomplished. Retests must meet the requirements of Ref (3.1 and 3.5) for the work performed.

4.9.1. Completed test documents are to be provided within five (5) working days after completion of testing.

4.10. Before performing any shipboard work, Contractor must interface with C246, sign the Letter of Understanding, and follow the work authorization process outlined in Reference (3.13) --- Local Work Template, Norfolk Naval Shipyard

6 OF 10 CUI

(NNSY) Work Authorization Form (WAF).

5. NNSY RESPONSIBILITIES:

5.1. Provide all required Submarine Orientation / Training to all personnel who will be conducting work onboard a submarine at NPTU.

5.1.1. Deck plate spot checks for comprehension may be conducted by the government.

5.1.2. The government may require Contractor personnel to carry proof of training in the form of a card, sticker on security badge, or other readily recognizable form.

5.1.3. Additional training in Tagout and Work Controls will be provided by NNSY to appropriate contractor personnel prior to or upon arrival at NPTU.

5.2. Security clearances and access for all contractor personnel will be managed by the Project Engineering & Planning Manager (PEPM).

5.3. Code 246 shall coordinate electrical isolations as required to allow Contractor to disassemble, clean inspect, repair and reassemble the Ship’s Port SSMG.

5.4. Perform all lifting and handling based on separate TWD.

5.5. Provide all temporary services as required to support shipboard work. This includes 440-Volt, three phase power (4- 30 Amp), potable water, a method of removing/ rinse water, 120 volt single phase power and LP Air (100 psi) at the work site.

5.6. Assign a Contracting Officer’s Representative (COR) to the work tasked within this SOW.

5.7. Code 246 to accomplish applicable procedures of Reference (3.4) for Port SSMG as OQE for work completion.

5.8. Provide all required Submarine Orientation / Training to all personnel who will be conducting work onboard a submarine at NNSY.

5.9. Assign a Contracting Officer’s Representative (COR) to the work tasked within this SOW.

6. SHIP’S FORCE RESPONSIBILITIES:

6.1. Provide work controls to allow contractor to perform work on Port SSMG.

6.2. Maintain Environmental Controls for SSMG work in accordance with SSMG MOA.

6.3. Perform a walk through inspection of contract areas with the contractor prior to executing work.

6.4. Provide parts to perform work on the Port SSMG. Parts to include the following:

6.4.1. Eight (8) each AC end brushes

6.4.2. Two (2) each overspeed brushes

6.4.3. One (1) each AC bearing

6.4.4. One (1) each DC duplex bearing set

6.4.5. Thirty two (32) each DC brushes

6.4.6. Three (3) each filters

7 OF 10 CUI

6.4.7. Two (2) AC End Slip Rings

6.4.8. Provide any additional material identified by Amee Bay

6.5. Perform appropriate Testing upon completion of work.

7. SECURITY REQUIREMENTS:

"Per FAR 22.102-1(a) entitled "Safety", Contractors are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard cognizance must follow Federal and State OSHA requirements OSHE OSHECM

Chapter Hazardous Energy Control (HEC) requirements or safety requirements for site specific location of the contract.

a. Contractors and Non-NNSY Government Agencies (NNGAs) are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard (NNSY) cognizance must adhere to Federal OSHA requirements for hazardous energy control IAW 29 CFR 1915.89 and must follow Hazardous Energy Control (HEC) procedures as identified in NAVSEA’s Occupational Safety, Health, and Environment Corporate Manual (OSHECM)

Chapter 250 (latest revision), when performing work under NNSY contract. All HEC work to be performed by Contractors and NNGAs requires that NNSY Technical Points of Contact (TPOCs) and/or Contracting Officer’s Representatives

(CORs) be notified of the HEC scope of work prior to starting work. Any changes or deviations in the initial scope of HEC work requires the NNSY TPOCs and/or CORs be informed of the change/deviation. Appendix 250.B-1 through B-3 of

OSHECM Chapter 250 for multiple employer work identifies when Contractors and NNGAs are required to assign their

Lockout/Tags-Plus Coordinator (LOTC) to coordinate HEC work with the cognizant NNSY LOTC. HEC locks shall be provided by the contractor or NNGA for their employees use. The HEC locks shall have red bodies with name labels or name tags affixed, identifying who installed the HEC lock(s) and a point of contact telephone number. HEC lock name labels and tags must be made of materials that will hold up to the environment to which they are exposed. HEC tags used for Tags-Plus HEC work shall be provided by the cognizant NNSY LOTC to the contractor or NNGA for their use if machinery, equipment, or systems (MES) cannot be locked out. OSHECM Chapter 250 Tags-Plus procedures will be strictly followed.

b. Contractors and NNGAs may obtain electronic copies of OSHECM Chapter 250 (latest revision) and access the OSHA

1915.89 web site by using the following link to NNSY’s public access web site:

http://www.navsea.navy.mil/shipyards/norfolk/default.aspx

c. Names and contact information for NNSY LOTCs and/or the Building Monitor will be provided by NNSY TPOC and/or

Contracting Officer Representative set forth elsewhere in this award document.

8. SAFETY:

Per FAR 22.102-1(a) entitled "Safety", Contractors are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard cognizance must follow Federal and State OSHA requirements and Norfolk Naval

Shipyard OSHE Program Manual, NAVSHIPYDNORINST P5090.2 requirements or safety requirements for site specific location of the contract.

Contractors and Non-NNSY Government Agencies (NNGAs) are hereby informed that their employees or representatives

8 OF 10 CUI

present on property under Norfolk Naval Shipyard (NNSY) cognizance must adhere to Federal OSHA requirements for hazardous energy control IAW 29 CFR 1915.89 and must follow Hazardous Energy Control (HEC) procedures as identified in NAVSEA’s Occupational Safety, Health, and Environment Corporate Manual (OSHECM) Chapter 250 (latest revision), when performing work under NNSY contract. All HEC work to be performed by Contractors and NNGAs requires that

NNSY Technical Points of Contact (TPOCs) and/or Contracting Officer’s Representatives (CORs) be notified of the HEC scope of work prior to starting work. Any changes or deviations in the initial scope of HEC work requires the NNSY

TPOCs and/or CORs be informed of the change/deviation. Appendix 250.B-1 through B-3 of OSHECM Chapter 250 for multiple employer work identifies when Contractors and NNGAs are required to assign their Lockout/Tags-Plus

Coordinator (LOTC) to coordinate HEC work with the cognizant NNSY LOTC. HEC locks shall be provided by the contractor or NNGA for their employees use. The HEC locks shall have red bodies with name labels or name tags affixed, identifying who installed the HEC lock(s) and a point of contact telephone number. HEC lock name labels and tags must be made of materials that will hold up to the environment to which they are exposed. HEC tags used for Tags-Plus HEC work shall be provided by the cognizant NNSY LOTC to the contractor or NNGA for their use if machinery, equipment, or systems (MES) cannot be locked out. OSHECM Chapter 250 Tags-Plus procedures will be strictly followed.

Contractors and NNGA’s may obtain electronic copies of OSHECM Chapter 250 (latest revision) and access the OSHA

1915.89 web site by using the following link to NNSY’s public access web site:

http://www.navsea.navy.mil/shipyards/norfolk/default.aspx

Names and contact information for NNSY LOTCs and/or the Facility Custodian will be provided by NNSY TPOC and/or

CORs set forth elsewhere in this award document.”

9. PLACE OF PERFORMANCE:

Contractor to perform repairs on the Port SSMG on a Moored Training Ship (MTS) Submarine located at Nuclear Power Training Unit (NPTU), Goose Creek, SC 29445.

10. DEFENSE BIOMETRIC IDENTIFICATION SYSTEMS (DBIDS) FOR INSTALLATION ACCESS:

Any new contractor, vendor or supplier requesting base access AFTER 31 May 2017 will be required to obtain a DBIDS credential. NCACS credentials will no longer be issued. Only DBIDS credentials will be issued to ALL contractors, vendors and suppliers seeking base access AFTER 14 August 2017.

Defense Biometric Identification System (DBIDS) increases installation security and communications by receiving frequent database updates on changes to personnel/credential status, law enforcement warrants, lost/stolen cards, and force protection conditions. The system provides a continuous vetting anytime the DBIDS card is scanned at an installation entry point.

If you currently have a Navy Commercial Access Control System (NCACS) card, the following is required to get a DBIDS credential:

• Present your NCACS Card and a completed copy of the SECNAV FORM 5512/1 to the base Visitor Control Center representative.

9 OF 10 CUI

• The VCC will pull up your information in the computer, ensuring all information is current and correct.

• Once your information is validated, a temporary DBIDS credential is provided.

• Your temporary credential will have an expiration date, prior to which you will need to obtain your permanent DBIDS credential (~ 90 days).

• For each additional U.S. Navy installation to which you need access, the first time you visit you only need to bring your

DBIDS credential and statement of purpose for base access when arriving at the Visitor Control Center.

• The representative will enter base access authorization and then you may proceed to work.

If you do NOT have an NCACS Card, the following is required to obtain a DBIDS credential:

• Present a letter or official document from my government sponsoring organization that provides the purpose for your access.

• Present valid identification, such as a passport or Real ID Act-compliant state driver's license.

• Present a completed copy of the SECNAV 5512/1 form to obtain your background check.

• Upon completion of the background check, the Visitor Control Center representative will complete the DBIDS enrollment process, which includes your photo, finger prints, base restrictions, and several other assessments; after all this is done, you will be provided with your new DBIDS credential.

• You may now proceed to work.

FOR ADDITIONAL QUESTIONS ABOUT OBTAINING A DBIDS CARD, CONTACT YOUR LOCAL BASE

VISITOR CONTROL CENTER. INFORMATION IS ALSO PROVIDED AT: www.cnic.navy.mil/om/dbids.ht

11. PORTABLE ELECTRONIC DEVICES:

"In accordance with COMSUBLANT/COMSUBPACINST 2075.1C, the use of Portable Electronic Devices (PEDs) while in or on Department of Navy Submarine spaces are prohibited. A portable electronic device (PED) is defined as any non-stationary electronic apparatus with singular or multiple capabilities of, but not limited to recording, storing, and/or transmitting data, voice, video, or photo images (e.g., cell phones, laptops, tablets and wearable devices such as fitness bands and smart watches).”

12. AUTHORIZATION OF ADDITIONAL WORK:

Any additional work outside the scope of this contract/purchase order shall have written authorization from the Contracting

Officer prior to executing any additional work. Any work performed without the written authorization of the Contracting

Officer shall be considered “At-Risk” and the government will have no legal obligation to pay for the work performed.

Pursuant 13.0004, once you have initiated performance of the work, this shall constitute your acceptance of the contract.

13. NNSY POINT OF CONTACT

13.1. Technical POC:

File details come from the government source that posted it. Updated .