About this file

This document is a specifications sheet for programmable reusable implantable temperature measuring devices for cattle and swine research models. The procurement requires 45 units of implantable temperature loggers with specific technical requirements, including a 5-minute or less measurement interval, up to 3-year battery life, and a temperature measurement resolution of +/- 0.003°C. The devices must fit within custom-made mounts approximately 8.3 mm x 25.4 mm.

The delivery is to be made to the LIRU office building located at 1604 E FM 1294, Lubbock, TX 79403 within 60 days of the order. The procurement prefers Star Oddi implantable temperature loggers or an equivalent product. The point of contact for this procurement is Nicole Sanchez, who can be reached at nicole.sanchez@usda.gov or 806-746-5353. The primary additional requirement is that the loggers must be able to fit within the custom-made mounts specified by the research team.

View the file

Other files for this federal contract opportunity

Other files attached to Purchase Temperature Loggers, newest first.
File Type Posted
RFQ_1232SA25Q0738.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATIONS

1.0 Specifications Description:

Programmable reusable implantable temperature measuring devices that measure and record temperature at frequent intervals (5 minutes or less) over a period of days to multiple weeks for use in cattle and swine research models.

(Name of Item)

Quantity: 45

Unit Type: Each

Minimum Requirements:

Programmable (5 min interval or less)

Reusable (up to 3 year battery life)

Implantable

Fit within custom-made mounts (approximately 8.3 mm x 25.4 mm)

Temperature measurement resolution of +/- 0.003oC

2.0 Place of Delivery

LIRU office building

3.0 Delivery Schedule

Item QTY Unit Place of Delivery Delivery Date

Programmable reusable implantable temperature measuring devices. Prefer Star Oddi implantable temperature logger or equal.

45 Each 1604 E FM 1294, Lubbock, TX 79403

Within 60 days

4.0 Delivery Point of Contact

Nicole Sanchez, nicole.sanchez@usda.gov; 806-746-5353

5.0 Additional Requirements

Loggers must be able to fit within custom-made mounts