This document contains a solicitation for a federal contract opportunity along with supporting specifications. The United States Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Pacific West Area is seeking two closed loop condenser kits to replace malfunctioning units on a Columbus Instruments LLC Micro-Oxymax Respirometer system located in Albany, California. The condenser kits must be brand name or equal to Columbus Instruments and fit the existing government-owned equipment, functioning as recommended by the original equipment manufacturer. Quotes are due by March 13, 2024 with delivery required within 30 days of award. The opportunity is set aside for small businesses.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ_12905B24Q0059 Terms and Conditions.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 - Specifications
Project: Closed Loop Condenser Kit, Brand Name or Equal to Columbus Instruments, LLC Micro- Oxymax Respirometer system
GENERAL INFORMATION
1. Scope of Work: Provide two closed loop condenser kits to replace condenser kits that are malfunctioning. The condenser kits need to fit the current Columbus Instruments, LLC Micro- Oxymax Respirometer system located in the Bioproducts Research Unit located in the Industrial Pilot Lab at 800 Buchanan St., Albany, CA 94710.
2. Background: The Oxymax Respirometer in the Industrial Pilot Lab is in a multiuser instrument that is used constantly. The components are subject to wear and tear. The condenser kits need to be replaced.
CONTRACTOR REQUIREMENTS
3. Technical Requirements: The contractor needs to provide the replacement condenser kits and instructions for replacing if needed. The support scientist that will be replacing the condenser kits has many years of experience operating the Oxymax Respirometer and has expertise in replacing damaged or worn components.
a) The condenser kits must exactly replace existing condenser kits.
b) The condenser kits must fit onto the government-owned Columbus Instruments LLC Micro
Oxymax Respirometer currently existing in the Industrial Pilot Lab located at USDA ARS WRRC, 800 Buchanan St., Albany, CA 94710.
c) The condenser kits must function as per recommendation of Columbus Instruments LLC, the OEM of the equipment.
4. Government Furnished: The Oxymax Respirometer is a government-owned instrument, and the new components will be replacements for the damaged/nonfunctioning components.
5. Deliverables / Schedule: 30 days after award.
6. Travel: No travel is required by the vendor. The new condenser kits will be replaced by the support scientist according to manufacturer instruction.
7. Contractor’s Key Personnel: Contractor’s personnel will be available to discuss installation of the condenser kits if needed.
8. Security Requirements: None. The condenser kits will be delivered by normal delivery routes.
9. Data Rights: Not applicable.