Attachment 1. Fiber Equipment List_SOO.docx
DOCX document 73 KB Posted
- Attached to
- TC Communications® Fiber Multiplexing Equipment Federal contract opportunity
- Solicitation number
- FA448420Q0016
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 5. Antiterrorism_Statement.pdf | ||
| Attachment 4. 52.212-3 Offeror Representations and Certifications-Commercial Items..docx | DOCX document | |
| 305th Fiber Combined Solicitation_Synopsis.pdf | ||
| Attachment 3. DoD Implementation Memo for 889(a)(1)(B).pdf | ||
| Attachment 2. Redacted TC Communications Brand Name Justification.pdf | ||
| Attachment 6. SFS Contractor Appendix 2016.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS 38TH CYBERSPACE ENGINEERING GROUP (ACC)
TINKER AIR FORCE BASE OKLAHOMA
STATEMENT OF OBJECTIVES (SOO)
for
TC Communications NavAids Fiber Mux Installation Joint Base McGuire-Dix-Lakehurst, NJ
23 July 2020
Prepared By
38 ES/ENPW
4064 Hilltop Road Tinker AFB OK 73145-2713
1.0 SCOPE
This Statement of Objectives (SOO) defines the requirements for the purchasing new TC Communications fiber multiplexing and distribution equipment for the Navigational Aid (NavAid) sites and RAPCON. The NavAid sites consisting of (2) Localizers, (2) Glide Slopes, and a VORTAC which are connected by base fiber cables to the RAPCON. These sites are located at Joint Base McGuire-Dix-Lakehurst (JBMDL), New Jersey.
2.0 REQUIREMENTS
GENERAL REQUIREMENTS
2.1.1 Warranty
The Contractor shall provide a warranty or manufacturer’s standard commercial warranty, whichever is longer. This warranty shall include a one year workmanship warranty. The warranty period shall start from the date of system and/or project acceptance. The Contractor shall provide written procedures and required information for warranty services at or prior to site acceptance.
2.1.2 Pandemic, Health and Safety Requirements
In the event of a pandemic, epidemic, or other emergency declared by Federal, State, or Local Governments; the contractor shall follow all installation requirements to include but not limited to rescheduling installation, use of protective equipment, and use of approved cleaning materials.
SPECIFIC REQUIREMENTS
This section describes the NavAids TC Communications systems and installation requirements. The 305th OSS/RAWS shall install the TC equipment outlined in the attached diagrams unless updated diagrams are available from the 85th Engineering Installation Squadron at time of installation.
Attachment 1, Equipment List
| Description |
| Quantity |
| Unit Price |
| Ext. Price |
RAPCON UNITS
TC8801R-L1SC-04-12
(3 Telephone Mux (Base) FXO, RackMount Card (-10C to 50C), 1300nm SM (20dB) SC, 4Ch (POTs, RJ11F), 12V DC
| 5 EA |
| $ |
| $ |
TC8802R-0000-32-13-12
Telephone Mux (Data) Data Exp Board, RackMount Card (-10C to 50C) RS232 (Async), bi-Direct D-Contact Closure/Detector, 12V DC
| 5 EA |
| $ |
| $ |
TCRM191R-01-01-PP
7 4U 19" Mux Card Cage for RackMount Card (-10C to 50C), Dual Power Cards, 115/240V AC - North American type and 115/240V AC – North American type with Power Back Plane
| 1 EA |
| $ |
| $ |
| Total |
| $ |
| Description |
| Quantity |
| Unit Price |
| Ext. Price |
SHELTER UNITS
TC8800S-L1SC-04-12
Telephone Mux (Base) FXS, Stand Alone (-10C to 50C), 1300nm SM (20dB) SC, 4Ch (POTs, RJ11F), 12V DC
| 5 EA |
| $ |
| $ |
TC8802S-0000-32-13-12
Telephone Mux (Data) Data Exp Board, Stand Alone (-10C to 50C), RS232 (Async), Bi-Direct D-Contact Closure/Detector, 12V DC
| 5 EA |
| $ |
| $ |
TC3PS-TB-25-01
Power Adapter for Stand Alone unit 12VDC output, Terminal Block 5.0mm,
2.5 Amp 115VAC North American type plug16 12VDC output,
| 10 EA |
| $ |
| $ |
| Total |
| $ |
| Description |
| Quantity |
| Unit Price |
| Ext. Price |
ATIS LINK UNITS
TC1901S-L1SC-4-12
20 POTs to Fiber Phone Extender, Stand Alone (-10C to 50C), 1300nm SM (20dB) SC, 4W Analog (600 Ohm), 12V DC
| 1 EA |
| $ |
| $ |
TC1901R-L1SC-4-12
POTs to Fiber Phone Extender, RackMount Card (-10C to 50C), 1300nm SM (20dB) SC, 4W Analog (600 Ohm), 12V DC
| 1 EA |
| $ |
| $ |
TCRM195R-S-01
1U 19" Mux Pizza Box Chassis for RackMount Card (-10C to 50C), Chassis with Power, 115/240V AC - North American type Plug
| 1 EA |
| $ |
| $ |
| Total |
| $ |
| Description |
| Quantity |
| Unit Price |
| Ext. Price |
CABLES
610-RJ11O-025
Cables, RJ11 6P4C with one open end cable, 25 FT.
| 26 EA |
| $ |
| $ |
610-RJ11O-050
Cables, RJ11 6P4C with one open end cable, 50 FT.
| 2 EA |
| $ |
| $ |
| Total |
| $ |
| Description |
| Quantity |
| Unit Price |
| Ext. Price |
SPARES
TC8801R-L1SC-04-12
Telephone Mux (Base) FXO, RackMount Card (-10C to 50C), 1300nm SM (20dB) SC, 4Ch (POTs, RJ11F), 12V DC
| 1 EA |
| $ |
| $ |
TC8802R-0000-32-13-12
Telephone Mux (Data) Data Exp Board, RackMount Card (-10C to 50C), RS232 (Async), Bi-Direct D-Contact Closure/Detector, 12V DC
| 1 EA |
| $ |
| $ |
TC8800S-L1SC-04-12
Telephone Mux (Base) FXS, Stand Alone (-10C to 50C), 1300nm SM (20dB) SC, 4Ch (POTs, RJ11F), 12V DC
| 1 EA |
| $ |
| $ |
TC8802S-0000-32-13-12
Telephone Mux (Data) Data Exp Board, Stand Alone (-10C to 50C), RS232 (Async), Bi-Direct D-Contact Closure/Detector, 12V DC
| 1 EA |
| $ |
| $ |
TC3PS-TB-25-01
Power Adapter for Stand Alone unit 12VDC output, Terminal Block 5.0mm,
2.5 Amp 115VAC North American type plug 44 12VDC output,
| 2 EA |
| $ |
| $ |
| Total |
| $ |
Grand Total
| Total |
| $ |
Page | 5 image1.wmf