Attachment 1 - AM12553352.pdf
PDF 141 KB Posted
- Attached to
- SP3300-25-Q-0022 - SPI Containers for DDAA Federal contract opportunity
- Solicitation number
- SP3300-25-Q-0022
- Issued by
- Defense Logistics Agency Distribution
About this file
This is a Special Packaging Instruction (SPI) document (Form DD 2169) for an electric DC motor/mount with NSN 6150-01-297-3818. The document provides detailed specifications for packaging the item, including military preservation method 41 per MIL-STD-2073-1, with a unit pack weight of 192.4 lbs and dimensions of 28.0 x 23.8 x 22.8 inches.
The packaging requirements include wrapping with PPP-C-1797 Type-I material, securing with A-A-883 tape, using a MIL-E-6060 barrier bag, and containing in a PPP-B-621 Style-7 Class-2 reusable container. Specific instructions detail cushioning requirements of 1/8" thick material at contact points and assembly of the container using lag bolts. The document includes technical drawings showing the assembly of wooden blocks and mounting components, along with precise dimensional specifications for the packaging construction. All wood materials must be heat-treated to 56 degrees Celsius for 30 minutes and certified according to international plant protection standards.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SP3300-25-Q-0022 0002.pdf | ||
| SP3300-25-Q-0022 0001.pdf | ||
| Attachment 2 - AK13192899.pdf | ||
| CSS SP3300-25-Q-0022.pdf | ||
| Attachment 4 - AK10615766.pdf | ||
| Attachment 5 - AK12770060.pdf | ||
| Attachment 6 - AMP12553710.pdf | ||
| Attachment 3 - AK13458887.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIAL PACKAGING INSTRUCTION
Form Approved OMB No. 0704-0188
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information
Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, Va 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subjected to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.
1. PART OR DRAWING NO. NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12553352 MOUNT, ELECTRIC, D.C. 19200 AM12553352
4. NATIONAL STOCK NO. 5.DATE OF
DRAWING/SPI(YYMMDD)
6. REVISION / ERR NO.
6150-01-297-3818 05-06-07 B/H05K2004
7. QUP / UNIT OF ISSUE 8. ICQ 9. UNIT PACK WT. (LB) (0.0) 10. UNIT PACK CU (CU.
FT.)(0.000)
11. UNIT PACK SIZE (INCHES)(00.0)
1/EA - 192.4 8.793 28.0 X 23.8 X 22.8
12. MILITARY PRESERVATION 18.
STEPS
19.
REQD
20.
DESCRIPTION
MIL-STD-2073-1, METHOD 41 1 AR WRAP, PPP-C-1797, TYPE-I, SEE NOTE (A)
13. CLEANING 2 AR TAPE, A-A-883, SEE NOTE (A)
* 3 1 BARRIER BAG, MIL-E-6060
14. DRYING 4 1 CONTAINER, PPP-B-621, STYLE-7, CLASS-2
* SEE NOTE (B)
15. PACKING
a. LEVEL A
MIL-STD-2073-1
b. LEVEL B
MIL-STD-2073-1
16. MARKING
MIL-STD-129
17. NOTES/DRAWINGS
* UNLESS OTHERWISE SPECIFIED, CLEANING AND DRYING SHALL BE IN ACCORDANCE WITH PARAGRAPH
5.2.1 OF MIL-STD-2073-1. WEIGHTS AND SIZES ARE ESTIMATED AND MAY VARY SLIGHTLY.
INTERMEDIATE PACKAGING AND PACKING WILL BE IN ACCORDANCE WITH SPECIFICATION MIL-STD-2073-1
OR AS OTHERWISE SPECIFIED HEREON.
(A) CUSHION ALL CONTACT POINTS BETWEEN ITEM AND BLOCKING WITH MINIMUM OF 1/8” THICK MATERIAL.
CUSHION ALL SHARP EDGES/PROTRUSIONS ON THE ITEM AND BLCOKING TO PROTECT BARRIER BAG.
SECURE WITH TAPE (AS APPLICABLE).
(B) REUSABLE CONTAINER. NAIL SUPERSTURCTURE (SIDES, ENDS, AND TOP) TOGETHER. LAG BOLT PERIMETER OF SUPERSTRUCTURE TO BASE ASSEMBLY, 3 ES. ¼” X 3” BOLTS PER END PANEL AND 2 EA. ¼ “ X
2” BOLTS PER SIDE PANEL.
ALL NON-MANUFACTURED WOOD USED IN PACKAGING SHALL BE HEAT-TREATED TO A CORE TEMPERATURE OF 56 DEGREES CELSIUS FOR A MINIMUM OF 30 MINUTES. THE BOX/PALLET MANUFACTURER AND THE MANUFACTURER OF WOOD USED AS INNER PACKAGING OR PALLET GATE/FILLER ASSEMBLIES SHALL BE AFFILIATED WITH AN INSPECTION AGENCY ACCREDITED BY THE BOARD OF REVIEW OF THE AMERICAN LUMBER STANDARD COMMITTEE. EACH BOX/PALLET OR OTHER PACKING MATERIAL SHALL BE MARKED TO SHOW THE CONFORMANCE TO THE INTERNATIONAL PLANT PROTECTION CONVENTION STANDARD. BOXES/PALLETS AND ANY OTHER WOOD PACKING MATERIAL MADE OF NON-MANUFACTURED WOOD SHALL BE CERTIFIED HEAT-TREATED. THE QUALITY MARK SHALL BE PLACED ON BOTH ENDS OF THE OUTER PACKAGING, BETWEEN THE END CLEATS OR END BATTENS; ON TWO SIDES OF THE PALLET OR OTHER
PACKING MATERIAL.
WSC: KF ITEM SIZE: 14.16 X 11.41 X 9.69 ITEM WEIGHT: 95.00 APPROVED: Vishwa N. Khanna
DISTRIBUTION STATEMENT A, UNLIMITED
DD Form 2169, JUN 1997 Previous editions are obsolete Page 1 of 5 Pages
SPECIAL PACKAGING INSTRUCTION (Continuation sheet)
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information
Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, Va 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subjected to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.
1. PART OR DRAWING NO. NOMENCLATURE 2. CODE INDENT 3. SPI NO.
12553352 MOTOR, ELECTRIC, D.C. 19200 AM12553352
4. NATIONAL STOCK NO. 5.DATE OF
DRAWING/SPI(YYMMDD)
6. REVISION / ERR NO.
6150-01-297-3818 05-06-07 B/H05K2005
DD Form 2169C, JUN 1997 Previous editions are obsolete Page 2 of 5 Pages
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information
Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, Va 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subjected to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.
1. PART OR DRAWING NO. NOMENCLATURE 2. CODE INDENT 3. SPI NO.
12553352 MOTOR, ELECTRIC, D.C. 19200 AM12553352
4. NATIONAL STOCK NO. 5.DATE OF
DRAWING/SPI(YYMMDD)
DD Form 2169C, JUN 1997 Previous editions are obsolete Page 3 of 5 Pages
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information
Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, Va 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subjected to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.
1. PART OR DRAWING NO. NOMENCLATURE 2. CODE INDENT 3. SPI NO.
12553352 MOTOR, ELECTRIC, D.C. 19200 AM12553352
4. NATIONAL STOCK NO. 5.DATE OF
DRAWING/SPI(YYMMDD)
DD Form 2169C, JUN 1997 Previous editions are obsolete Page 4 of 5 Pages
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information
Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, Va 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subjected to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.
1. PART OR DRAWING NO. NOMENCLATURE 2. CODE INDENT 3. SPI NO.
12553352 MOTOR, ELECTRIC, D.C. 19200 AM12553352
4. NATIONAL STOCK NO. 5.DATE OF
DRAWING/SPI(YYMMDD)
DD Form 2169C, JUN 1997 Previous editions are obsolete Page 5 of 5 Pages