Attach. 1 Salient Characteristics 12Jul23.pdf

PDF 644 KB Posted

Attached to
Explosion Proof Heater Federal contract opportunity
Solicitation number
FA462023QA243
Issued by
Department of the Air Force Air Mobility Command

About this file

This document provides salient characteristics for an explosion proof heater solicited by the Department of the Air Force Air Mobility Command. Key details include that the heater would have a 12-inch fan diameter, produce 50.0 kW of power, and operate on 208 volts AC single phase at 60 Hertz. The heater would meet Class I and II Division 1 and 2 certification for hazardous locations with Groups C, D, F and G temperature code of T38. It would also meet Class I Zones 1 and 2 certification for Groups IIA and IIB at a T3 temperature code. Additional characteristics include 24VAC controls and an integrated electronic room thermostat with a range of 40 to 80 degrees Fahrenheit. The related federal contract opportunity is solicitation number FA462023QA243 for an explosion proof heater.

View the file

Other files for this federal contract opportunity

Other files attached to Explosion Proof Heater, newest first.
File Type Posted
23QA243Combo18Jul23 - Ex Proof Heater.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Explosion Proof Heater

Saliant Characteristics

1. 12in Fan Diameter

2. 050.0 kW

3. 208 Volts AC, 1 Phase, 60 Hertz Ex-Proof Motor

4. Class I and II, Div. 1&2; Groups C, D, F &G Temp Code T38

5. Class I, Zones 1&2, Groups IIA & IIB, T3

6. 24VAC Controls

7. Built-in Electronic room thermostat (Range: 40°F to 80°F / 5°C to 25°C)

Attach. 1 Salient Characteristics 12Jul23