NPDES Compliance Commercial Inspection Checklist Marine Corps Base Hawaii, Oahu, Hawaii
Note: Y – Yes; D ‐ BMPs are implemented, but are deficient; N – No; n/a– Not applicable
* If additional space is needed, reference applicable item no. on “Additional Notes” form. Page 1 of __
GENERAL INFORMATION
Bldg. No.: Area:
Activity Description:
Date: Time: Weather: Inspected by:
Facility POC: Phone:
SECTION 1 ‐ TRAINING/EDUCATION
1.1 Relevant training is provided to employees regarding storm water pollution prevention. ☐ YES ☐ NO
1.2 Applicable Safety Data Sheets (SDS) are easily available? ☐ YES ☐ NO
1.3 Employees are aware of practices to prevent storm water pollution prevention and that discharging non‐storm water to the storm drain is prohibited.
☐ YES ☐ NO
1.4 Training brochure was provided to facility personnel during this visit? ☐ YES ☐ NO
Item No.
Criteria Y D N n/a Notes:
* If deficient, specify & include location/photo no.
SECTION 2 ‐ MATERIAL/WASTE STORAGE & DISPOSAL
2.1 Containers are properly labelled.
2.2 HAZMAT/HAZWASTE is stored indoors
or protected from exposure rainfall.
2.3 Secondary containment/storage units
(i.e. hazardous material lockers) are well maintained and adequate.
2.4 HAZMAT/HAZWASTE loading and
unloading occurs indoors or with BMPs to minimize risk of pollutant exposure to storm water.
2.5 Raw Materials are stored indoors, or
protected from storm water runoff.
2.6 Regular collection of waste or
materials for recycling by a qualified person(s).
2.7 Storage and disposal BMPs adequately
minimize risk of pollutant exposure to storm water.
SECTION 3 ‐ RESTAURANT/FOOD SERVICE
3.1 Grease trap/interceptor functions
properly.
3.2 Grease trap/interceptor is well
maintained.
Marine Corps Base Hawaii, Oahu, Hawaii Bldg No.: ___________
Note: Y – Yes; D ‐ BMPs are implemented, but are deficient; N – No; n/a– Not applicable
* If additional space is needed, reference applicable item no. on “Additional Notes” form. Page 2 of __
Item No.
Criteria Y D N n/a Notes:
* If deficient, specify & include location/photo no.
SECTION 4 ‐ VEHICLES/ HEAVY EQUIPMENT MAINTENANCE
4.1 Equipment kept onsite appears well
4.2 Maintenance activities are conducted
indoors or with adequate BMPs to minimize pollutant exposure to storm water.
4.3 BMPs are implemented to prevent
spills and leaks during maintenance activities and storage.
4.4 Salvage equipment is drained of fluids
prior to storage onsite.
4.5 BMPs appear to be adequate and well
SECTION 5 ‐ VEHICLE/HEAVY EQUIPMENT WASHING
5.1 Vehicle and equipment washing is
conducted at a designated wash rack or offsite location.
5.2 Wash water and debris is properly
collected and disposed of.
5.3 BMPs/engineered controls appear to
be adequate and well maintained.
SECTION 6 ‐ FUELING
6.1 Fueling area is covered or has
engineered controls to prevent contact with storm water.
6.2 BMPs/engineered controls appear to
be adequate and well maintained.
SECTION 7 ‐ GOOD HOUSEKEEPING
7.1 Parking lots and outdoor areas are
kept clear of debris.
7.2 Trash/recycling receptacles are
covered and not leaking.
7.3 Unused or obsolete equipment/
supplies is properly disposed of.
7.4 Work areas are kept orderly, so that
spills/leaks can be easily identified and cleaned.
7.5 Spill kits are adequately supplied and
readily available near storage and work areas.
7.6 Spills are contained and cleaned in a
timely manner.
7.7 Work areas are not washed down to
storm drain system.
7.8 Proper collection and disposal of wash
water to sewer, or offsite location.
Note: Y – Yes; D ‐ BMPs are implemented, but are deficient; N – No; n/a– Not applicable
* If additional space is needed, reference applicable item no. on “Additional Notes” form. Page 3 of __
Item No.
Criteria Y D N n/a Notes:
* If deficient, specify & include location/photo no.
SECTION 8 ‐ STORM DRAIN SYSTEM
8.1 Storm drain inlets are functioning
properly
8.2 Storm drain structures are well
8.3 Storm drain stenciling/ signage to
promote pollution prevention.
8.4 BMPs appear to be adequate and well
SECTION 9 ‐ GENERAL OBSERVATIONS
Structural BMPs (check all that apply):
☐ Oil Water Separator
☐ Grease Trap (indoor)/ Interceptor (outdoor)
☐ Wash Rack
☐ Berm Around Critical Areas
☐ Impervious Surfaces Used at Critical Areas
☐ Vacuum System for Sanding/Sawdust
☐ Detention/Retention Basin
☐ Erosion/Slope Protection (i.e. rip rap, geotextiles)
☐ Inlet Protection (i.e. filter fabric, filter sock)
☐ Sediment/Debris Trap
☐ Hydrodynamic Separator
☐ Infiltration Pit (i.e. gravel or sand)
☐ Vegetated Swale
☐ Other (specify) ‐
Criteria Y N Notes:
* If YES, specify & include location/photo no. If already documented, note applicable item no.
9.1 Dry weather discharge ☐ ☐
9.2 Evidence of non‐storm water spills
outdoors
9.3 Illicit connections to the MS4 (i.e. floor
drains)
9.4 Subject to flooding or impacts from
offsite storm water
9.5 Evidence of erosion ☐ ☐
OVERALL ASSESSMENT:
BMPs appear to be implemented in a satisfactory manner, such that there is no immediate and significant risk to storm water quality.
☐ YES ☐ NO
If above answer is NO, A critical deficiency has been observed, immediate follow‐up action is required.
☐ YES ☐ NO
Based on the current commercial activities and observations of this inspection, the current priority level assigned to this facility is adequate.
☐ YES ☐ NO
If NO, the priority level assigned to this facility should be changed to:
1 – HIGH 2 – MODERATE 3 ‐ LOW
Page 4 of __
Additional Notes:
NPDES Compliance Industrial Inspection Checklist Marine Corps Base Hawaii, Oahu, Hawaii
Note: Y – Yes; D - BMPs are implemented, but are deficient; N – No; n/a– Not applicable
* If additional space is needed, reference applicable item no. on “Additional Notes” form. Page 1 of __
GENERAL INFORMATION
Bldg. No.: Area:
Activity Description:
Date: Time: Weather: Inspected by:
Facility POC:
Phone:
SECTION 1 - TRAINING/EDUCATION
1.1 Relevant training is provided to employees regarding storm water pollution prevention. ☐ YES ☐ NO
1.2 Applicable Safety Data Sheets (SDS) are easily available? ☐ YES ☐ NO
1.3 Employees are aware of practices to prevent storm water pollution and that discharging non-storm water to the storm drain is prohibited. ☐ YES ☐ NO
1.4 Training brochure was provided to facility personnel during this visit? ☐ YES ☐ NO
No. Criteria Y D N n/a Notes:
* If deficient, specify & include location/photo no.
SECTION 2 - GOOD HOUSEKEEPING
2.1 Spills are contained and cleaned in a
timely manner. ☐ ☐ ☐ ☐
2.2 Outdoor work areas are swept
regularly to avoid accumulation of debris.
2.3
Work areas are not hosed down outdoors or washed to storm drain. ☐ ☐ ☐ ☐
2.4 Work areas are kept orderly, so that
spills/leaks can be easily identified and cleaned.
2.5 Proper collection and disposal of wash
water to sewer, or offsite location – including storm water that enters indoor facility (i.e. roof leaks)
2.6 Spill kits are adequately supplied and
readily available near storage and work areas.
2.7 Trash/recycling receptacles are
covered and not leaking. ☐ ☐ ☐ ☐
2.8 Unused or obsolete equipment/
supplies is properly disposed of. ☐ ☐ ☐ ☐
SECTION 3 -STORAGE & DISPOSAL
3.1 Containers are properly labelled. ☐ ☐ ☐ ☐
3.2 Significant material/waste is properly
stored indoors or protected from exposure to storm water.
Note: Y – Yes; D - BMPs are implemented, but are deficient; N – No; n/a– Not applicable
* If additional space is needed, reference applicable item no. on “Additional Notes” form. Page 2 of __
Item No. Criteria Y D N n/a Notes:
* If deficient, specify & include location/photo no.
SECTION 3 -STORAGE & DISPOSAL (continued)
3.3 Secondary containment (i.e. hazardous
material lockers) is adequate and well maintained.
3.4 Loading and unloading is indoors or
under cover with adequate BMPs. ☐ ☐ ☐ ☐
3.5 Routine collection of waste/recycling
by qualified personnel. ☐ ☐ ☐ ☐
SECTION 4 - VEHICLES/ EQUIPMENT MAINTENANCE
4.1 Equipment stored onsite is well
maintained or has BMPs to prevent storm water exposure to pollutants.
4.2 Maintenance is conducted indoors or
under cover with adequate BMPs. ☐ ☐ ☐ ☐
4.3 BMPs are implemented to prevent
spills and leaks during maintenance activities.
4.4 Salvage equipment is drained of fluids
prior to storage onsite. ☐ ☐ ☐ ☐
SECTION 5 – VEHICLE/ EQUIPMENT WASHING
5.1 Vehicle and equipment washing is
conducted at a designated wash rack or appropriate offsite location.
5.2 If onsite, wash water and debris is
properly collected and disposed of. ☐ ☐ ☐ ☐
5.3 BMPs for onsite wash facility appear
adequate and well maintained. ☐ ☐ ☐ ☐
SECTION 6 - FUELING
6.1 Fueling area is covered or has
structural BMPs (i.e. bermed) to prevent storm water pollution.
6.2 BMPs for fueling activities appear
adequate and well maintained. ☐ ☐ ☐ ☐
SECTION 7 - STORM DRAIN SYSTEM
7.1 Storm drain inlets are functioning
properly. ☐ ☐ ☐ ☐
7.2 Storm drain structures are well
maintained. ☐ ☐ ☐ ☐
7.3 Storm drain stenciling/ signage. ☐ ☐ ☐ ☐
7.4 Inlet protection/ structural BMPs
appear adequate and well maintained. ☐ ☐ ☐ ☐
Note: Y – Yes; D - BMPs are implemented, but are deficient; N – No; n/a– Not applicable
* If additional space is needed, reference applicable item no. on “Additional Notes” form. Page 3 of __
SECTION 8 – STORM WATER POLLUTION CONTROL PLAN (SWPCP)
Significant Materials/Wastes Onsite(check all that apply) Place an asterisk (*) beside those that may be exposed to storm water if improperly handled.
☐ Jet Fuel ☐ Gasoline ☐ Diesel ☐ Mixed Fuel ☐ Batteries (new/used) ☐ Battery Acid ☐ Lubricating Oil
☐ Transmission Oil ☐ Brake Fluid ☐ Hydraulic Fluid ☐ Antifreeze ☐ Grease ☐ Degreaser ☐ Used Oil
☐ Paint ☐ Alodine (corrosion treatment) ☐ Paint Thinner ☐ Solvents ☐ Mineral Spirits ☐ Polish ☐ Adhesives
☐ Detergent ☐ Cleaners ☐ Sandblast Grit ☐ Saw Dust ☐ Aggregate ☐ Scrap Metal
☐ Other, specify -
Structural BMPs (check all that apply):
☐ Oil Water Separator ☐ Grease Trap (indoor)/ Interceptor (outdoor) ☐ Wash Rack ☐ Berm Around Critical Areas ☐ Impervious Surfaces Used at Critical Areas ☐ Vacuum System for Sanding/Sawdust ☐ Detention/Retention Basin ☐ Erosion/Slope Protection (i.e. rip rap, geotextiles)
☐ Inlet Protection (i.e. filter fabric, filter sock) ☐ Sediment/Debris Trap ☐ Hydrodynamic Separator ☐ Infiltration Pit (i.e. gravel or sand) ☐ Vegetated Swale ☐ Other (specify) -
No. Criteria Y N n/a Notes:
*If NO, specify
8.1 Is a copy of SWPCP, including applicable
BMPs, kept onsite?
8.2 Does the SWPCP BMP list match the
current site conditions and operations?
8.3 Significant material/waste storage and handling areas are accurately reflected on map.
SECTION 9 - GENERAL OBSERVATIONS
No. Criteria Y N Notes: (If YES, specify & include location/photo no. If already documented, note applicable item no.)
9.1 Dry weather discharge. ☐ ☐
9.2 Evidence of non-storm water spills
outdoors.
9.3 Illicit connections to the MS4 (i.e. floor
drains).
9.4 Subject to flooding or impacts from
offsite storm water.
9.5 Evidence of erosion. ☐ ☐
OVERALL ASSESSMENT:
Can this facility qualify for Conditional No Exposure Certification?
All industrial materials/activities are protected by storm resistant shelter preventing exposure to storm water.
☐ YES ☐ NO
BMPs appear to be implemented in a satisfactory manner, such that there is no immediate and significant risk to storm water quality.
☐ YES ☐ NO
If above answer is NO, Has a critical deficiency has been observed, requiring immediate follow-up action? ☐ YES ☐ NO
Page 4 of __
No. Additional Notes: