Atch_02_Quote_and_Price_Schedule.xlsx
XLSX spreadsheet 16 KB Posted
- Attached to
- HACH Field Service for Yosemite NP Federal contract opportunity
- Solicitation number
- 140P8523Q0053
About this file
This document is a price quote schedule for field service and equipment maintenance for water quality monitoring instruments at multiple National Park Service locations within Yosemite National Park under solicitation 140P8523Q0053. The quote schedule requests pricing for equipment service and calibration of 21 turbidimeters, 11 colorimeters, 4 pH probes, 3 controllers and 1 chlorine analyzer located across 6 different park sites over a base year and two option years. Pricing is also requested for the purchase and installation of additional equipment including two UVAS probes, three controllers, one turbidimeter, and two non-installed turbidimeters. Response to the solicitation should include pricing for all listed items and locations for evaluation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P8523Q0053.pdf | ||
| Atch_01_Scope_of_Work.pdf | ||
| Atch_03_DOL_Wage_Determination.pdf | ||
| Combined_Synopsis_and_Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Offeror__________________________________________________________ | RFQ 140P8523Q0053 | |||||
| Submit pricing for all items; failure to do so may render the quotation non-responsive. If no line item exists for a portion of the work, include the costs in a related line item. | ||||||
| Location: Backcountry Utilities, El Portal, California | ||||||
| Quantity | Service | Base Year | Option Yr 1 | Option Year 2 | ||
| 2100Q Turbidimeters | #62 16010C047160 | 1 | Annual | |||
| #61 16010C046945 | 1 | Annual | ||||
| #52 16010C046909 | 1 | Annual | ||||
| #51 16010C047161 | 1 | Annual | ||||
| #42 16010C047151 | 1 | Annual | ||||
| #41 16010C047139 | 1 | Annual | ||||
| #32 16010C047154 | 1 | Annual | ||||
| #31 16010C047144 | 1 | Annual | ||||
| #22 16010C047145 | 1 | Annual | ||||
| #21 16010C047140 | 1 | Annual | ||||
| #12 16010C047150 | 1 | Annual | ||||
| #11 16010C046904 | 1 | Annual | ||||
| Subtotal | $0.00 | $0.00 | $0.00 | |||
| Pocket Colorimeter II | #62 14040E245043 | 1 | Annual | |||
| #61 14040E245064 | 1 | Annual | ||||
| #52 14040E245062 | 1 | Annual | ||||
| #51 14040E245044 | 1 | Annual | ||||
| #42 09110E137419 | 1 | Annual | ||||
| #41 09060E124789 | 1 | Annual | ||||
| #32 09060E124678 | 1 | Annual | ||||
| #31 09060E124786 | 1 | Annual | ||||
| #22 09060E124679 | 1 | Annual | ||||
| #21 09060E125032 | 1 | Annual | ||||
| #12 09060E125033 | 1 | Annual | ||||
| #11 09060E124788 | 1 | Annual | ||||
| TM 18060E360884 | 1 | Annual | ||||
| Subtotal | $0.00 | $0.00 | $0.00 |
| Location: Backcountry Utilities, El Portal, California (continued) | ||||||
| Quantity | Service | Base Year | Option Yr 1 | Option Year 2 | ||
| DR300 Pocket Colorimeter | 21120B00338 | 1 | Annual | |||
| HQ40d DO Probe | 1311009683 | 1 | Annual | |||
| 1700E Turbidimeters x 2 (Hardwired) | P/N TBD | 1 | Annual | |||
| SE100 Controller (Hardwired) | P/N TBD | 1 | Annual | |||
| CL17 Chlorine Analyzer (Hardwired) | P/N TBD | 1 | Annual | |||
| SC 200 Controller with pH sensor | 1406447318 / LXV404.99.00552 | 1 | Annual | |||
| Subtotal | $0.00 | $0.00 | $0.00 |
| Location: El Portal Utilities, El Portal, California | ||||||
| Quantity | Service | Base Year | Option Yr 1 | Option Year 2 | ||
| UVAS sc PROBE, 50mm | LXV418.99.90002 | 2 | Semi Annual | |||
| sc200 Controller | LXV404.99.90002 | 3 | Annual | |||
| 2100N Lab Turbidity Instrument | 4700060 | 1 | Annual | |||
| sc100 Controller | 1406447318/LXV401.52.00002 | 1 | Annual | |||
| Subtotal | $0.00 | $0.00 | $0.00 | |||
| Location: Wawona Wastewater Plant, Wawona, California | ||||||
| Quantity | Service | Base Year | Option Yr 1 | Option Year 2 | ||
| TL-2300 Turbidimeter | S/N 2022020C0079 | 1 | Annual | |||
| 1720E Turbidimeter | S/N 160200054586 | 1 | Annual | |||
| SC200 Power Supply | S/N 1601C0154459 | 1 | Annual | |||
| HQ411d pH/mV meter | S/N 220500042681 | 1 | Annual | |||
| DR 890 Colorimeter | S/N 990790007571 | 1 | Annual | |||
| DR 890 Colorimeter | S/N 020290019960 | 1 | Annual | |||
| DR 900 Colorimeter | S/N 151240001028 | 1 | Annual | |||
| Subtotal | $0.00 | $0.00 | $0.00 |
| Location: Wawona Water Plant, Wawona, California | ||||||
| Aqua Trend Signal Output Module | S/N 980800001520 | 1 | Annual | |||
| 1720D Turbidimeter | S/N 980800002961 | 1 | Annual | |||
| 1720E Turbidimeter | S/N 160200054589 | 1 | Annual | |||
| 1720D Turbidimeter | S/N 980800003004 | 1 | Annual | |||
| SC 200 Power Supply | S/N 1601C0137149 | 1 | Annual | |||
| TL-2300 Turbidimeter | S/N 2019060C0082 | 1 | Annual | |||
| HQ411d pH/mV meter | S/N 220500042729 | 1 | Annual | |||
| DR 820 Colorimeter | S/N 020320019921 | 1 | Annual | |||
| DR 820 Colorimeter | S/N 990820007795 | 1 | Annual | |||
| DR 300 Colorimeter | TBD | 1 | Annual | |||
| Pocket Colorimeter II | S/N 17050E329180 | 1 | Annual | |||
| Pocket Pro Colorimeter | S/N 190420001014 | 1 | Annual | |||
| 2100 Q Turbidimeter | S/N 22080D001790 | 1 | Annual | |||
| 2100 P Turbidimeter | S/N 15050C040949 | 1 | Annual | |||
| 2100 Q Turbidimeter | S/N 16080C051413 | 1 | Annual | |||
| Sension 4 | S/N 020400000953 | 1 | Annual | |||
| Sension 5 Coductivity | S/N 990800000479 | 1 | Annual | |||
| Sension 3 pH | S/N 001000001603 | 1 | Annual | |||
| Sension + pH-1 | S/N 907051 | 1 | Annual | |||
| 1720 E Turbidimeter | (TBD) Not Installed | 1 | Annual | |||
| 1720 E Turbidimeter | (TBD) Not Installed | 1 | Annual | |||
| Subtotal | $0.00 | $0.00 | $0.00 |
Yearly Totals $0.00 $0.00 $0.00
Total Contract Value $0.00
Attachment 02 Quote/Price Schedule
File details come from the government source that posted it. Updated .