Atch 01 - Requirements Document FANG ISS.pdf

PDF 122 KB Posted

Attached to
Keysight X-Series Signal Generators Federal contract opportunity
Solicitation number
FA9101-22-Q-B001
Issued by
Department of the Air Force Materiel Command Test Center

About this file

This requirements document specifies the need for six Keysight X-Series vector signal generator units by the 746th Test Squadron. The units must include specific model numbers, hardware configurations, and licensing options. Key details include a delivery deadline of no later than 90 days after receipt of order, with shipment of all hardware and documentation to the specified facility at Holloman Air Force Base. The related federal contract opportunity posted by the Department of the Air Force Materiel Command Test Center seeks offers for the Keysight X-Series signal generators as defined in the requirements document. Evaluation will be based on meeting the technical requirements for the specified equipment.

View the file

Other files for this federal contract opportunity

Other files attached to Keysight X-Series Signal Generators, newest first.
File Type Posted
Combined Synopsis Solicitation FANG ISS V2.pdf PDF
Atch 01 - Requirements Document FANG ISS V2.pdf PDF
Atch 03 - JA Brand Name_FANG ISS Redacted.pdf PDF
Combined Synopsis Solicitation FANG ISS.pdf PDF
Atch 02 - FAR DFARS AFFARS Prov and Clauses FANG ISS.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Keysight X-Series signal generators Requirements Document

For 704th Test Group/746th Test Squadron

4 October 2021

1.0 PURPOSE

The 704th Test Group (704 TG) mission is to be the premier provider of unique test and evaluation capabilities relevant to tomorrow’s warfighter through world-class people improving technical excellence, cost-effectiveness, and agility. The 746th Test Squadron (746 TS) is assigned to the 704 TG.

The 746 TS is requesting the acquisition of 6 EXG vector signal generator units to be allocated for the FANG system. To ensure compatibility with current systems, the requirements for these vector signal generators include a matching model number and options that define the hardware capability requirements, licensing options and specific configuration parameters that must be provided at the time of purchase.

2.0 SCOPE

The configuration requirements and nomenclature of options is listed below:

Part Number Title/Name Quantity N5172B Standard front panel configuration 6 N5172B-503 Frequency range, 9 kHz to 3 GHz 6 N5172B-1EA High output power 6

N5172B-655 Upgrade baseband generator from 60 to 120 MHz RF bandwidth

N5172B-653 ARB baseband generator (60 MHz RF bandwidth, 32 Msa)

N5172B-022 Upgrade baseband generator memory from 32 Msa to 512 Msa

N5172B-UNW Narrow pulse modulation 6 N5172B-UNT AM, FM, phase modulation 6

N5172B-006 Instrument security and removable memory card

1CP104A

Rack mount flange and handle kit 88.1mm H (2U) - brackets, handles, hole plugs, New Phantom Gray Color

N5180403B Calibrated AWGN 6,940.70 0.00 6,940.70 4 27,762.80 Node-locked perpetual license

*KeysightCare software support (12-month) and KeysightCare assured First Year Support included.

3.0 MILESTONES

To be delivered no later than 90 days ARO.

4.0 DELIVERABLES

The contractor shall deliver all hardware and documentation to 746 TS/TGGA, Attn: Carlos Ruiz, at 1644 Vandergrift Road, Building 1265, Holloman Air Force Base, New Mexico 88330.

1.0 PURPOSE
2.0 SCOPE
4.0 DELIVERABLES

File details come from the government source that posted it. Updated .