Road_Package.pdf
PDF 4 MB Posted
- Attached to
- 2016 Gap Fire - Burned Area Emergency Response Federal contract opportunity
- Solicitation number
- AG-9AC7-S-17-0011
About this file
1. Road Package
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CA9.pdf | ||
| PAL_Fire_Plan_030613_(3).pdf | ||
| AG-9AC7-S-17-0011.pdf | ||
| SF_24_BID_BOND.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ken Bigelow
Ken Kellogg
Jeff Marzel
Christine Frisbee
LOCALITY MAP
NO SCALE
ITEM
NO
DESCRIPTION
METHOD OF
MEASURE
-MENT
PAY
UNIT
46N55
ROAD NO. & TOTALS
CQ LS ALL ALL
ALL ALLLSQ LS
2.21 5.40DQ MILE
ALL ALL
ALL ALL
2.84 1.88
46N60FH 12 46N50 47N77
ALL
ALL
15101 MOBILIZATION
30304 ROADBED RECONDITIONING, RESTORE DRAINAGE, GRADE ROAD, PULL
DITCH (WHERE APPLICABLE), REINFORCE OUTSLOPE (WHERE APPLICABLE)
15754 SOIL EROSION & POLLUTION CONTROL
AQ EA 0 0 0 0 1
60605 FLARED END SECTION
LSQ LS ALL ALL ALL ALL ALL
60701 CLEAN/RECONDITIONING/REPAIR EXISTING DRAINAGE STRUCTURES
AQ EA 0 0 0 24 0
20420D DRAINAGE EXCAVATION, TYPE IV ROLLING DIP, CLASS LB (LOWBOY MOD)
AQ EA 7 0 0 0 0
60452 DROP INLET COVER, TYPE A
6.60
AQ LF 6 4 0 0 0
60403 DROP INLET ASSEMBLY W/ COVER TYPE A
AQ EA 26 40 0 0 0
20420C DRAINAGE EXCAVATION, TYPE IV ROLLING DIP, CLASS L (LOWBOY)
AQ EA 0 0 9 0 38
20420B DRAINAGE EXCAVATION, TYPE I ROLLING DIP, CLASS M (LOG TRUCK)
AQ EA 0 2 0 0 0
20420A DRAINAGE EXCAVATION, TYPE I ROLLING DIP, CLASS L (LOWBOY)
AQ EA 0 0 3 0 18
20420E DRAINAGE EXCAVATION, TYPE IV ROLLING DIP, CLASS M (LOG TRUCK)
60211A 24"Ø CORRUGATED METAL PIPE, 0.079-IN THICKNESS FOR STL, METHOD (A) AQ LF
250 210 0 0 30
AQ EA 0 1 0 0 0
63308 REMOVING & RESETTING STEEL GATE SYSTEM (TO INCLUDE POSTS)
DQ CY 0 700 0 70 0
20401 EXCAVATION, PLACEMENT METHOD (B), COMPACTION (B)
DQ CY 5 180 0 30 60
25101 MACHINE PLACED RIPRAP, CLASS III, COMMERCIAL SOURCE *NOT PART OF
ROLLING DIP*
60211B 48"Ø CORRUGATED METAL PIPE, 0.109-IN THICKNESS FOR STL, METHOD (A) AQ LF
0 0 0 0 60
METAL PIPE, PIPE ARCHES OR ARCHES
SECTION 602 OR 605 604 605 621 251
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
C H
O N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
E D
R A
I N
S F
G R
A N
U L
A
F
I L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
S
T A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON DESIGN DATA ONLY
& ARE SUBJECT TO ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
0.14FH 12
0.16
0.23
0.37
0.39
0.60
0.66
0.77
0.86
0.92
0.94
0.99
1.11
1.20
1.28
1.35
1.40
1.55
1.62
1.70
1.77
1.83
3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL DROP INLET (DI)
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL RELIEF CMP
A
A 3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL DROP INLET (DI)
3010 CONSTRUCT TYPE IV ROLLING DIP
7525 CONSTRUCT TYPE IV ROLLING DIP, RIPRAP INLET, RELIEF CMP
INSTALL DROP INLET LID ONLY
3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL DI LIDA
A
6020 INSTALL DI LID + ED @ CMP OULETA
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL DIA
3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL DIA
INSTALL DROP INLET LID, CONSTRUCT TYPE IV ROLLING DIPA
INSTALL DROP INLET LID ONLYA
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL RELIEF CMP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL RELIEF CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
INSTALL DROP INLET LID ONLYA
INSTALL DROP INLETA
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL NEW 24"Ø CMP50
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
FH 12
1.91FH 12 3010 CONSTRUCT TYPE IV ROLLING DIP
1.43 3010 CONSTRUCT TYPE IV ROLLING DIPFH 12
1.49 3010 CONSTRUCT TYPE IV ROLLING DIPFH 12
0.50 3010 CONSTRUCT TYPE IV ROLLING DIP
0.57 3010 CONSTRUCT TYPE IV ROLLING DIP
FH 12
FH 12
AA
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
A
I N
S F
G R
A N
U L
L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON
DESIGN DATA ONLY & ARE SUBJECT TO
ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
46N60 0.12
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
3010 CONSTRUCT TYPE IV ROLLING DIP
0.19
0.30
0.39
0.43
0.55
0.59
0.66
0.86
0.92
1.01
1.08
1.27
1.38
1.44
1.55
1.66
1.77
2.70
3.20
3.85
3.87
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL DROP INLETA
6020 CONSTRUCT TYPE IV DIP, INSTALL 24"CMP + ED @ EXIST CMP70
6020 CONSTRUCT TYPE IV DIP, INSTALL DI @ INLET & ED @ OUTLETA
6020 CONSTRUCT TYPE IV DIP, INSTALL 24"CMP + ED @ EXIST CMP40
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
6020 CONSTRUCT TYPE IV DIP, INSTALL DI @ INLET & ED @ OUTLETA
6020 CONSTRUCT TYPE IV DIP,REPLACE 5' CMP, INSTALL DI + ED10
3010 CONSTRUCT TYPE IV DIP, INSTALL DI @ INLETA
3010 CONSTRUCT TYPE IV ROLLING DIP
12040 CONSTRUCT TYPE IV ROLLING DIP, REMOVE & RIPRAP DAM
18060 CONSTRUCT TYPE IV ROLLING DIP, REMOVE & RIPRAP DAM
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
1.92
2.04
2.14
2.20
MAINTAIN EXISTING CMP, CLEAN OUT CATCH BASIN
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
INSTALL DROP INLET LID, CONSTRUCT TYPE IV ROLLING DIPA
FH 12
FH 12
FH 12
FH 12
3.90
3.98
4.00
4.05
4.12
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
METAL PIPE, PIPE ARCHES OR ARCHES
SECTION 602 OR 605 604 605 621 251
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
A
I N
S F
G R
A N
U L
L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON
DESIGN DATA ONLY & ARE SUBJECT TO
ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
46N60 4.14
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
3010 CONSTRUCT TYPE IV ROLLING DIP
4.24
4.33
4.41
4.51
4.57
4.67
4.76
4.90
4.97
5.04
5.16
5.22
5.24
5.28
5.34
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
46N60
46N60
46N60
46N60
46N60
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL RELIEF CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N60
46N55 0.11
0.56
2.02
2.04
2.18
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
46N55
46N55
46N55
46N55
2.28
2.32
2.38
2.41
2.48
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
46N55
46N55
46N55
46N55
46N55
METAL PIPE, PIPE ARCHES OR ARCHES
SECTION 602 OR 605 604 605 621 251
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
A
I N
S F
G R
A N
U L
L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON
DESIGN DATA ONLY & ARE SUBJECT TO
ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
2.51 3010 CONSTRUCT TYPE I ROLLING DIP46N55
2.5646N55
2.7046N55
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
0.0646N50
0.08
0.33
0.37
0.41
0.54
0.56
0.62
0.68
0.79
0.81
0.84
0.90
0.93
1.00
1.13
1.15
0.46
MAINTAIN EXISTING DIP
MAINTAIN EXISTING CMP
3010 CONSTRUCT TYPE IV ROLLING DIP, MAINTAIN CMP
12040 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE IV ROLLING DIP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP, MAINTAIN CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP, MAINTAIN CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP, MAINTAIN CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
0.3347N77
0.36
0.50
0.68
0.74
0.97
1.00
1.06
1.09
1.14
1.22
1.25
1.37
1.44
1.48
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
1.25
1.40
1.41
1.45
1.48
METAL PIPE, PIPE ARCHES OR ARCHES
SECTION 602 OR 605 604 605 621 251
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
A
I N
S F
G R
A N
U L
L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON
DESIGN DATA ONLY & ARE SUBJECT TO
ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
1.5946N50
1.61
1.62
1.67
1.86
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
MAINTAIN CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
MAINTAIN CMP
MAINTAIN CMP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP
46N50
46N50
46N50
46N50
46N50
46N50
46N50
46N50
0.77 12040 CONSTRUCT TYPE IV ROLLING DIP, INSTALL 48"Ø CMP47N77 60
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
A
I N
S F
G R
A N
U L
L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON
DESIGN DATA ONLY & ARE SUBJECT TO
ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
1.51
1.66
1.88
2.02
2.05
2.07
2.12
2.32
47N77 2.39
2.44
2.49
2.58
2.60
2.64
2.68
2.74
2.77
2.83
2.88
2.92
2.97
3.11
4.31
4.39
4.43
4.87
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE IV ROLLING DIP, INSTALL END SECTION118"
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP30
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL 24"Ø CMP
6020 CONSTRUCT TYPE IV ROLLING DIP, INSTALL ED @ CMP OUTLET
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
4.24
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
C O
R R
U G
A T
I O
N S
Ø
C M P
Ø
C M P
Ø
C M P
E L
B O
W
B R
A N
N
N
E N
D
S
E C
T I O
N
I N
L E
T
R
I S
E R
P I P
E
I N
L E
T
P R
E F
A B
R I C
A T
A
I N
S F
G R
A N
U L
L
L E
R
M A
T E
R I A
L
C
Y
I N
C H
I N
C H
I N
C H
I N
C H
A N
C H
A
K E
G E
O T
E X
T I L
E
SIZE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
D E
B R
C
K
T
Y P
E
TYPE
PREFAB DRAIN
CORR. METAL SPILLWAY RIPRAP
REMARKS
VIII V III SY
SITE
MILE POST
ROAD NO.
NOTES:
1. QUANTITIES ON THIS SHEET ARE BASED ON
DESIGN DATA ONLY & ARE SUBJECT TO
ADJUSTMENTS BEFORE & DURING
CONSTRUCTION TO SUIT FIELD CONDITIONS.
ABBREVIATIONS:
Al = ALUMINUM ALLOY Fe = GALVANIZED STEEL CMP = CORRUGATED METAL PIPE
SPP = STRUCTURAL PLATE PIPE SPPA = STRUCTURAL PLATE PIPE ARCH SPA = STRUCTURAL PLATE ARCH
PP = PERFORATED PIPE CMPA = CORRUGATED METAL PIPE ARCH CSBC = CORRUGATED STEEL BOX CULVERT
SIZE TYPE NO TYPE
CU. YDS.
C L
A S
S
C L
A S
S
C L
A S
S
I N
L E
T
A S
S E
M B
L Y
FLUME OUTLET
PIPE
Ø
C M P
Ø
C M P
Ø
C M P
Ø
C M P
4.95
5.07
5.11
5.30
5.33
5.64
5.97
6.08
6.1047N77
6.24
6.49
6.52
6.54
6.57
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
MAINTAIN CMP, CLEAN TREES & DEBRIS FROM CATCH BASIN
3010 CONSTRUCT TYPE IV ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
3010 CONSTRUCT TYPE I ROLLING DIP
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
47N77
H20 TRK
EXISTING CULVERT (IF APPLICABLE) CLEAN INLET & OUTLET AS NECESSARY
EXISTING CATCH BASIN. CLEAR ANY LOOSE DEBRIS, SEDIMENT
BUILDUP OR ANY POTENTIAL CULVERT OBSTRUCTIONS FROM
W/IN 10' RADIUS OF INLET. DE-WATERING IS REQUIRED
UNLESS OTHERWISE APPROVED BY THE ENGINEER
10'-0"
NOTE:
1. ALL SLASH SHALL BE DISPOSED OF ACCORDING TO SECTION
203.05(F) & IS INCIDENTAL TO SPECIFICATION 60701
2. CULVERT SHALL BE CLEANED IN PLACE SO THAT FLOW IS NOT
OBSTRUCTED FROM ENTERING, FLOWING THROUGH OR
EXITING THE CULVERT.
3. SEDIMENT REMOVED SHALL BE DISPOSED OF AT THE
DISPOSAL SITE DESIGNATED ON THE GROUND BY THE
ENGINEER.
4. COST OF REMOVAL & DISPOSAL OF MATERIAL SHALL BE
INCIDENTAL TO SPECIFICATION 60701
ROAD WIDTH
VARIES
VARIES
CLEAR ANY LOOSE DEBRIS, SEDIMENT
BUILDUP OR ANY POTENTIAL CULVERT OBSTRUCTIONS FROM
W/IN 10' RADIUS OF OUTLET UNLESS OTHERWISE APPROVED BY THE ENGINEER
10'-0"
NOTE: FINAL LOCATION
OF ALL RELIEF
CULVERTS TO BE
SLIGHTLY ADJUSTED BY
THE ENGINEER IN THE
FIELD TO OPTIMIZE
CATCHING OVERFLOW
OF PLUGGED CULVERTS
IN THE BASE OF THE
FILLS.
NOTE: FINAL LOCATION OF ALL DIPS
TO BE SLIGHTLY ADJUSTED BY THE
ENGINEER IN THE FIELD TO
OPTIMIZE PREVENTING DIVERSION
OF WATER FROM THE
DRAW/DRAINAGE DOWN THE ROAD
& BACK INTO NATURAL CHANNEL
2"
1"
#4
#200
80-100 (±6)
64-94 (±6)
40-69 (±6)
31-54 (±6)
4.0-7.0 (±3)
NOTE: FINAL LOCATION OF ALL DIPS
TO BE SLIGHTLY ADJUSTED BY THE
ENGINEER IN THE FIELD TO
OPTIMIZE PREVENTING DIVERSION
OF WATER FROM THE
DRAW/DRAINAGE DOWN THE ROAD
& BACK INTO NATURAL CHANNEL
CTY ROAD 8F001
PROJECT LIMIT
REF JCT COUNTY ROAD 8F001
BEGIN RECONDITION
DRAINAGE STRUCTURES
BEGIN ROAD
RECONDITIONING
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
FOREST HIGHWAY (FH) 12 ROAD
MP 0.00
MP 0.66 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID, CONSTRUCT TYPE
IV ROLLING DIP RT
MP 0.14 REF 18"Ø CMP, MAINTAIN CMP
INSTALL DROP INLET,
CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 0.16 REF 18"Ø CMP, MAINTAIN CMP
INSTALL DROP INLET,
CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 0.23 REF 18"Ø CMP, MAINTAIN CMP,
CONSTRUCT TYPE IV ROLLING
DIP LT. INSTALL 24"Ø X 40'
RELIEF CULVERT
MP 0.37 REF 18"Ø CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP RT.
MP 0.39 REF 18"Ø CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP RT. ARMOUR CMP INLET,
INSTALL NEW 24"Ø X 40' RELIEF
CMP
MP 0.60 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID
MP 0.77 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID, INSTALL ENERGY
DISSIPATER @ CMP OUTLET
MP 0.86 CONSTRUCT TYPE IV ROLLING
DIP RT. REF BERM RT
MP 0.92 CONSTRUCT TYPE IV ROLLING
DIP RT.
MP 0.94 REF 18"Ø CMP, INSTALL DI,
CONSTRUCT TYPE IV ROLLING
DIP RT
MP 0.99 REF 18"Ø CMP, INSTALL DI,
CONSTRUCT TYPE IV ROLLING
DIP RT. BEGIN REINFORCE
INSLOPE. REF THRU CUT
MP 1.05 REF END THRU CUT. END
REINFORCE INSLOPE
MP 1.11 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID, CONSTRUCT TYPE
IV DIP RT
MP 1.20 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS L (LOWBOY)
MP 0.57 CONSTRUCT TYPE IV ROLLING
DIP RT. REF BERM RT
MP 0.50 REF JCT LT JUST ABOVE MP,
W/ 18"Ø CMP W/ DI,
CONSTRUCT TYPE IV ROLLING
DIP RT TO PREVENT
OVERFLOW DIVERSION FROM
CMP OR ROAD ABOVE
MP 1.28 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
INSTALL NEW 24"Ø X 60' RELIEF
CMP, SKEW NEW CMP
MP 1.35 REF 24"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT.
INSTALL NEW 24"Ø X 60' RELIEF
CMP, SKEW NEW CMP
MP 1.40 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
MP 1.55 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID
MP 1.62 REF 18"Ø CMP, INSTALL NEW DI
MP 1.70 REF RUSTED & DAMAGED 18"Ø
CMP, INSTALL NEW 24"Ø X 50'
CMP, CONSTRUCT TYPE IV
ROLLING DIP RT
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
FOREST HIGHWAY (FH) 12 ROAD
MP 2.14 REF 18"Ø CMP W/ DI, INSTALL
NEW DI LID, CONSTRUCT TYPE
IV ROLLING DIP RT
MP 1.77 CONSTRUCT TYPE IV ROLLING
DIP RT.
MP 1.83 REF 18"Ø CMP, INSTALL NEW
DI, CONSTRUCT TYPE IV
ROLLING DIP RT
MP 1.82 REF JCT LT.
MP 2.21 REF PROJECT LIMIT
MP 1.92 REF CMP W/ TOWER DI,
MAINTAIN CMP, DI & CLEAN
OUT CATCH BASIN.
MP 1.94 REF JCT RT.
MP 2.04 REF 24"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
MP 2.06 REF JCT RT.
MP 2.20 REF 24"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS L (LOWBOY)
MP 1.49 CONSTRUCT TYPE IV ROLLING
DIP RT.
MP 1.43 CONSTRUCT TYPE IV ROLLING
DIP RT.
MP 1.91 CONSTRUCT TYPE IV ROLLING
DIP RT.
REF CTY ROAD 8F001
BEGIN RECONDITION
DRAINAGE STRUCTURES
BEGIN ROAD
RECONDITIONING
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
46N60
MP 0.00
N
REF MIDDLE HORSE BRIDGE.
ALL EQUIPMENT CROSSING
BRIDGES SHALL BE HIGHWAY
LEGAL OR HAVE AN
INDIVIDUAL FOREST SERVICE
OVER-LOAD PERMIT FOR EACH
PIECE OF EQUIPMENT
MP 0.01
MP 0.12 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 0.19 REF 18"Ø CMP & GATE,
CONSTRUCT TYPE IV ROLLING
DIP LT. RELOCATE GATE &
GATE POSTS AS NEEDED TO
CONSTRUCT DIP. GATE
SYSTEM RE-LOCATION TO BE
PAID UNDER 63308
MP 0.30 CONSTRUCT TYPE I ROLLING
DIP LT.
N
MP 0.43 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
INSTALL ENERGY DISSIPATER
@ CMP OUTLET
MP 0.55 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 0.39 REF 78"Ø CMP W/ BEVELED
INLET, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 0.59 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 0.66 REF 24"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
INSTALL ENERGY DISSIPATER
@ CMP OUTLET
MP 0.86 REF 18"Ø CMP, INSTALL NEW
DI, CONSTRUCT TYPE IV
ROLLING DIP RT
MP 0.92 REF 18"Ø CMP W/ DAMAGED
INLET, INSTALL NEW 24"Ø X 70'
RELIEF CMP, INSTALL ENERGY
DISSIPATER @ 18" Ø OUTLET,
CONSTRUCT TYPE IV ROLLING
DIP RT
MP 1.01 REF 18"Ø CMP, INSTALL NEW
DI, CONSTRUCT TYPE IV
ROLLING DIP RT. INSTALL
ENERGY DISSIPATER @ CMP
OUTLET. ALIGN DIP W/ DIP
BELOW
MP 1.08 REF 18"Ø CMP W/ DAMAGED
INLET, INSTALL NEW 24"Ø X40'
RELIEF CMP, INSTALL ENERGY
DISSIPATER @ 18" Ø OUTLET,
CONSTRUCT TYPE IV ROLLING
DIP RT
MP 1.27 REF 24"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
MP 1.38 CONSTRUCT TYPE IV ROLLING
DIP RT
MP 1.44 REF 18"Ø CMP W/ DAMAGED
INLET, INSTALL NEW 24"Ø X 60'
RELIEF CMP, INSTALL ENERGY
DISSIPATER @ 18"Ø CMP
OUTLET, CONSTRUCT TYPE IV
ROLLING DIP RT
N
MP 1.55 REF 18"Ø CMP, INSTALL NEW
DI, INSTALL ENERGY
DISSIPATER @ CMP OUTLET,
CONSTRUCT TYPE IV ROLLING
DIP RT
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS L (LOWBOY)
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
46N60
N
N
N
MP 1.66 REF 18"Ø CMP, INSTALL NEW
DI, CONSTRUCT TYPE IV
ROLLING DIP RT
MP 1.77 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
MP 2.70 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
REMOVE FILL & 18"Ø IN CATCH
BASIN ABOVE CROSSING. SEE
DETAIL PAGE 21
MP 3.20 REF 24"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP RT
REMOVE FILL & 18"Ø IN CATCH
BASIN ABOVE CROSSING. SEE
DETAIL PAGE 22
MP 3.85 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 3.87 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 3.90 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.00 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 3.98 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 4.05 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.12 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.14 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.24 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.33 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.41 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.51 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.57 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.67 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
INSTALL NEW 24"Ø X 40' RELIEF
CMP
MP 4.76 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.90 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 4.97 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 5.04 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
ROADS BASE PACKAGE
46N60
N
MP 5.16 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 5.22 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 5.24 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 5.28 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 5.34 REF 18"Ø CMP, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 5.40 REF PROJECT LIMIT
ROADS BASE PACKAGE
46N60 MP 2.70
FS ROAD 46N60 MP 2.70
DRAINAGE ABOVE
SEDIMENT DAM
DRAINAGE BELOW
SEDIMENT DAM &
ABOVE ROAD
SEDIMENT DAM
O
L
K
A
D
S
P
O
I
R
S
E
D
I E
M
N
T
DRAINAGE BELOW
ROAD
ROADS BASE PACKAGE
46N60 MP 3.20
FS ROAD 46N60 MP 3.20
DRAINAGE ABOVE
SEDIMENT DAM
DRAINAGE BELOW
SEDIMENT DAM &
ABOVE ROAD
SEDIMENT DAM
O
K
A
D
S
P
O
I
R
S
E
D
I E
M
N
T
DRAINAGE BELOW
ROAD
CTY ROAD 8D006
REF FS ROAD 46N55
BEGIN RECONDITION
DRAINAGE STRUCTURES
BEGIN ROAD
RECONDITIONING
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
46N55
MP 0.00
N
MP 0.56 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 0.11 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 2.02 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 2.04 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 2.18 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 2.28 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 2.32 CONSTRUCT TYPE IV ROLLING
DIP RT
MP 2.38 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.41 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.48 CONSTRUCT TYPE I ROLLING
DIP RT.
N
MP 2.70 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.51 CONSTRUCT TYPE I ROLLING
DIP RT.
N
MP 2.84 REF PROJECT LIMIT
DO NOT DISTURB WATERBARS
BEYOND
MP 2.56 MAINTAIN LEAD OFF DITCH LT
PAY ITEM WILL BE UNDER
30304
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS M (LOG TRUCK)
REF JCT COUNTY ROAD
8F003/PVT ROAD RT
BEGIN RECONDITION
DRAINAGE STRUCTURES
BEGIN ROAD
RECONDITIONING
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
46N50
MP 0.00
N
MP 0.46 REF CMP, INSTALL ENERGY
DISSIPATER @ OUTLET,
CONSTRUCT TYPE IV ROLLING
DIP LT
MP 0.06 MAINTAIN EXISTING DIP LT.
MP 0.33 REF CMP, MAINTAIN CMP,
CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 0.37 REF CMP, MAINTAIN CMP,
INSTALL ENERGY DISSIPATER
@ OUTLET, CONSTRUCT TYPE
IV ROLLING DIP LT.
MP 0.41 REF 18"Ø CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 0.81
MP 0.08 MAINTAIN EXISTING CMP.
MP 0.35 REF FS BOUND MARKER LT
MP 0.54 CONSTRUCT TYPE IV ROLLING
DIP LT
MP 0.56 CONSTRUCT TYPE IV ROLLING
DIP LT
MP 0.62 CONSTRUCT TYPE IV ROLLING
DIP LT
MP 0.68 REF CMP, REMOVE PERCHED
MATERIAL ABOVE CATCH
BASIN, CONSTRUCT TYPE IV
ROLLING DIP LT
MP 0.79 CONSTRUCT TYPE IV ROLLING
DIP LT
CONSTRUCT TYPE IV ROLLING
DIP LT
MP 0.84 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT
MP 0.90 CONSTRUCT TYPE IV ROLLING
DIP LT. EXTEND DIP FROM MP
0.89 TO 0.91
MP 0.93 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT, END REMOVE
BERM LT
MP 1.00 CONSTRUCT TYPE IV ROLLING
DIP LT
MP 1.13 CONSTRUCT TYPE IV ROLLING
DIP LT
MP 1.15 CONSTRUCT TYPE IV ROLLING
DIP LT
N
N
MP 0.91 BEGIN REMOVE BERM LT
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS L-M (LOWBOY MOD)
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
ROADS BASE PACKAGE
46N50
N
MP 1.25 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.43 REF JCT FS 47N77 LT
MP 1.40 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.41 REF CMP, MAINTAIN CMP
MP 1.45 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.48 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.59 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.61 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.67 CONSTRUCT TYPE IV ROLLING
DIP LT.
MP 1.62 REF CMP, MAINTAIN CMP
MP 1.86 REF MAPLE CULLCH,
REF CMP, MAINTAIN CMP
MP 1.88 REF PROJECT LIMIT
N
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS L-M (LOWBOY MOD)
FS 46N50 ROAD
REF JCT FS ROAD 46N50
BEGIN RECONDITION
DRAINAGE STRUCTURES
BEGIN ROAD
RECONDITIONING
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
GAP BAER
ROADS BASE PACKAGE
47N77
MP 0.00
N
REF FISH GULCH BRIDGE. ALL
EQUIPMENT CROSSING
BRIDGES SHALL BE HIGHWAY
LEGAL OR HAVE AN
INDIVIDUAL FOREST SERVICE
OVER-LOAD PERMIT FOR EACH
PIECE OF EQUIPMENT
MP 0.02
MP 0.33 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 0.36 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 0.50 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 0.68 CONSTRUCT TYPE I ROLLING
DIP LT.
N
N
MP 0.77 REF CMP, REF MAIN DRAW,
CONSTRUCT TYPE IV ROLLING
DIP LT. INSTALL 48"Ø X 60' CMP
MP 0.97 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 1.00 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 1.06 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT. INSTALL
ENERGY DISSIAPTER @ CMP
OUTLET
MP 1.09 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT. INSTALL
ENERGY DISSIAPTER @ CMP
OUTLET
MP 1.14 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT. INSTALL
ENERGY DISSIAPTER @ CMP
OUTLET
MP 1.22 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 1.37 CONSTRUCT TYPE I ROLLING
DIP LT.
MP 1.44 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 1.25 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT. INSTALL
ENERGY DISSIAPTER @ CMP
OUTLET
MP 1.48 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
MP 1.51 REF 18"Ø CMP, INSTALL METAL
END SECTION, CONSTRUCT
TYPE IV ROLLING DIP LT.
MP 1.66 CONSTRUCT TYPE I ROLLING
DIP LT.
NOTE: ALL ROLLING DIPS ON THIS ROAD SHALL BE CLASS M (LOG TRUCK)
MP 0.74 REF CMP, CONSTRUCT TYPE IV
ROLLING DIP LT.
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
ROADS BASE PACKAGE
47N77
N
N
N
MP 1.88 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.02 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.05 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.07 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.12 REF CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP RT
MP 2.32 REF CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP RT. INSTALL ENERGY
DISSIPATER @ CMP OUTLET
MP 2.39 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.44 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.49 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.58 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.60 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.64 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.68 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.74 REF DAMAGED CMP, REMOVE
& INSTALL 24"Ø X 30' CMP
CONSTRUCT TYPE IV ROLLING
DIP RT.
MP 2.77 REF CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP RT. INSTALL ENERGY
DISSIPATER @ CMP OUTLET
MP 2.83 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.88 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.92 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 2.97 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 3.11 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 3.79 REF NARROW ROAD IN DRAW.
CONTRACTOR TO FIELD
VERIFY EQUIPMENT CAN
SAFELY NEGOTIATE ROAD IN
THIS LOCATION. IF TOO TIGHT,
ENGINEER MAY RE-LOCATE
DIPS BETWEEN MP 3.79 & MP
5.02 TO SELECT LOCATIONS
BETWEEN MP 0.00 & MP 3.79.
***AT THE CONTRACTOR'S DISCRETION, HAZARDOUS VEGETATION CAN BE BRUSHED/CLEAREDREMOVED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK. WORK ASSOCIATED W/ THIS VEGETATION SHALL BE INCIDENTAL TO THE WORK BEING PERFORMED***
ROADS BASE PACKAGE
47N77
N
N
N
MP 4.24 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 4.31 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 4.39 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 4.43 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 4.87 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 4.95 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 5.02 REF NARROW ROAD IN DRAW.
IT IS HIGHLY UNLIKELY HEAVY
EQUIPMENT CAN NEGOTIATE
THIS TURN SAFELY FROM THIS
SIDE. SITES BEYOND THIS MP
WILL NEED TO BID COMING
FROM LOW GAP OR WIDEN THE
ROAD @ NO ADDITIONAL COST
TO GOVT.
MP 5.11 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 5.33 REF CMP, MAINTAIN CMP
CONSTRUCT TYPE IV ROLLING
DIP RT
MP 5.30 REF CMP, MAINTAIN CMP,
CLEAN CATCH BASIN
MP 6.08 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.10 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.24 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.49 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.52 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.54 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.57 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 6.60 REF PROJECT LIMIT
LOW GAP IS ~ MP 12.50
MP 5.97 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 5.64 CONSTRUCT TYPE I ROLLING
DIP RT.
MP 5.07 CONSTRUCT TYPE I ROLLING
DIP RT.
| P01 |
| P02 |
| P03 |
| P04 |
| P05 |
| P06 |
| P07 |
| P08 |
| P09 |
| P10 |
| P11 |
| P12 |
| P13 |
| P14 |
| P15 |
| P16 |
| P17 |
| P18 |
| P19 |
| P20 |
| P21 |
| P22 |
| P23 |
| P24 |
| P25 |
| P26 |
| P27 |
| P28 |
File details come from the government source that posted it. Updated .