GENERAL NOTES-ROAD LOGS
GENERAL NOTES
Section 203 – Removal of Structures and Obstructions: All pipes being replaced (and their accessories) shall be removed and disposed off government land in compliance with state, federal and local regulations. This section does NOT include any excavation, only the removal of the pipe and accessories.
Section 303 – Reconditioning: This work consists of reconditioning ditches, shoulders, roadbeds, aggregate surfaces, or the entire road.
Section 602 – Culverts and Drains: As stated in the specification, the contractor shall determine the final location, skew, length, elevations, and grade. This also includes installation of down pipes on existing culverts. Do not order or install culverts until the CO has accepted the final structure size, length, and alignment.
Section 607 – Cleaning, Reconditioning, and Repairing Existing Drainage Structures - Work under this section includes specifically the cleaning of all culvert inlets and outlets up to 48” diameter and any material inside the culvert when noted in the road log. The road log will detail the items of work required under this pay item.
Final shaping of the road at culvert installation and replacement sites shall be constructed so no water diversion potential exists in case the culvert plugs and fails. This shall be accomplished by shaping a dip in the road over the culvert location, or installing a rolling dip downgrade of the culvert at the soonest possible location.
Pay Item 20467 – Drivable Drainage Dip: This pay item includes the excavation, shaping, and aggregate surfacing for rolling dip installation. The aggregate shall be spread the full length of the constructed dip, the full width of the road, and at a 4 inch compacted depth.
Pay Item 30201 – Roadway Aggregate: This pay item includes aggregate surfacing over culvert locations, spot rocking, and where required in the general notes and plans.
Pay Item 62540 – Mulching, Straw Bales: Apply uniformly across disturbed ground (on fill slopes at culvert installation sites), at rates noted on the plans.
ROAD LOGS
Road MP Treatment 1S07 0 Intersection with County Road 512 (Van Duzen Road) 1S07 0-10.0 Clean ditch of fire debris where needed.
1S07 2.5 CMP with crushed inlet. Cut inlet open.
1S07 2.6 Clean 18" cmp inlet.
1S07 2.7 Add 3-foot slotted riser pipe to 18" cmp inlet.
1S07 3.2 Clean 18" culvert and install 3-foot slotted riser pipe.
1S07 3.3 Clean 18" cmp outlet.
1S07 3.7 Clean 18" cmp inlet and outlet.
1S07 3.8 Clean 18" cmp inlet.
1S07 3.9 Clean 18" cmp inlet.
1S07 4.9 Clean trash rack 1S07 5.6 Install 160' of 18" cmp (downspout) 1S07 6.2 Clean outlet.
1S07 7.2 Clean inlet catch basin.
1S07 8.5 Clean inlet catch basin.
1S07 8.7 Clean 18" cmp inlet.
1S07 9.3 Clean inlet catch basin.
1S07 9.5 Clean inlet catch basin.
1S07 10.2 Clean tree off outlet.
1S07 10.3 Clean inlet catch basin.
1S07 10.4 Clean culvert.
1S07 10.5 Install metal end section on 18" cmp.
1S07 10.6 Add 3-foot slotted riser pipe to 18" cmp inlet.
1S07 10.7 Add 3-foot slotted riser pipe to 18" cmp inlet.
1S07 10.75 Add 3-foot slotted riser pipe to 18" cmp inlet.
1S07 10.9 Install driveable dip 1S07 11 Add 3-foot slotted riser pipe to 18" cmp inlet.
1S07 11.1 Clean 18" cmp inlet.
2S08 0 Intersection with 1S07 (i.e., not beginning of road) 2S08 0.01 Clean outlet and add 3-foot slotted riser pipe to 18" cmp inlet.
2S08 0.2 Clean inlet and outlet 2S08 0.5 Install metal end section on 18" cmp.
2S08 0.51 Clean inlet and ditch 2S08 0.6 Clean existing snorkel 2S08 1.1 Clean inlet and outlet 2S08 1.2 Install driveable dip 2S08 1.3 Clean inlet catch basin.
2S08 1.4 Clean inlet catch basin.
2S08 1.5 Install metal end section on 18" cmp.
2S08 1.6 Install metal end section on 18" cmp.
2S08 1.7 Install metal end section on 18" cmp.
2S08 2.5 Dozer Line Rehab - Suppression Repair 2S08 3.1 2 18-inch culverts. Install metal end sections.
2S08B 0 Intersection with 2S08B 2S08B 0.1 Clean 18" cmp inlet.
2S08B 0.5 Install driveable dip 2S08B 0.6 Install driveable dip 2S08B 1.9 Add 3-foot slotted riser pipe to 18" cmp inlet.
2S08B 2.2 Clean inlet catch basin.
2S08B 3 Gate, end survey 2S08B
18 waterbars will be flagged on the ground.
1S41 0 Intersection with FR 1S23 at top of SFM.
1S41 0.2 Bad rut across road.
1S41 0 -2.07 32 waterbars are flagged on the ground.
1S41 0.32 clean 18" cmp 1S41 0.4 clean 18" cmp 1S41 1.36 clean 18" cmp 1S41 1.99 clean 18" cmp
2S27 0 Intersection with County Road 501 (Ruth Lake Road) 2S27 0.05 Intersection with private drive and FS gate 2S27 0.06 Clean 18" cmp inlet.
2S27 0.3 Clean three 18" cmps with slotted riser pipes, install new lids 2S27
0.8 Suppression Repair - waterbar dozer line 100' up from the intersection with 2S27
2S27 1.3 Suppression Repair - clean catch basin 2S27 1.5 Road impassible at rock slide - end survey
1S55 0 Intersection with County Road 501 (Ruth Road) 1S55 0.05 FS gate 1S55
0.65 Remove tree from 24" cmp inlet and install critical dip downslope of crossing
1S55 0.8
Add 3-foot slotted riser pipe and lid to 18" cmp inlet. Install dip downslope of crossing
1S55 0.9
Install metal end section on 24" cmp. Install dip downslope of crossing
1S11 0 Intersection with County Road 512 (Van Duzen Road)
1S11 1 Install metal end section on 18" cmp.
1S11 1.1 48" cmp with high rustline.
1S11 1.6 Clean 18" cmp inlet.
1S11 6.7 Add 3-foot slotted riser pipe to 18" cmp inlet.
1S11 6.75 18" cmp with high rustline.
1S11 7 Tree across road 1S11 7.51 Install metal end section on 18" cmp.
1S11 8.08 Replace 18" cmp with 24" cmp x 35-feet 1S11 8.26 Replace 18" cmp with 24" cmp x 35-feet 1S11 8.38 Clean 24" cmp inlet.
1S11 8.93 Clean 18" cmp inlet.
1S11 9.01 Clean 18" cmp inlet.
1S11G Lassic 6 waterbars will be flagged on the ground. Clean 13 cmp.
1S12B Lassic 1 waterbar will be flagged on the ground. Clean 5 cmp.
1S19 Lassic 17 waterbars will be flagged on the ground. Clean 11 cmp.
2S08C Lassic 12 waterbars will be flagged on the ground.
2S20 Lassic 12 waterbars will be flagged on the ground. Clean 5 cmp.
2S24 Lassic 7 waterbars be flagged on the ground. Clean 1 cmp.
2S24A Lassic 1 waterbar will be flagged on the ground.
2S33 Lassic 11 waterbars will be flagged on the ground. Clean 9 cmp.
2S33A Lassic 11 waterbars will be flagged on the ground.
2S34 Lassic 14 waterbars will be flagged on the ground. Clean 2 cmp.
2S36 Lassic 11 waterbars will be flagged on the ground. Clean 7 cmp.
1S04 Lassic 4 waterbars will be flagged on the ground.
1S10 Lassic 4 waterbars will be flagged on the ground. Clean 6 cmp.
1S11F Lassic 6 waterbars will be flagged on the ground. Clean 32 cmp.
File details come from the government source that posted it. Updated .