Additional_Emergency_Fire_Precautions.docx

DOCX document 13 KB Posted

Attached to
FY 2017 Release of Planted Trees Federal contract opportunity
Solicitation number
AG-9AB5-S-17-0037
Issued by
Department of Agriculture Forest Service R5-Pacific Southwest Region

About this file

Additional Emergency Fire Precautions

View the file

Other files for this federal contract opportunity

Other files attached to FY 2017 Release of Planted Trees, newest first.
File Type Posted
FY17_Station_Fire_Release_PAL_Fire_Plan_030613.doc DOC document
Attachment_A_FY17_StationRelease_1_10_17.docx DOCX document
PPQ.docx DOCX document
Project_Experience_Questionnaire.docx DOCX document
Final_SationRelease_Vicinity.pdf PDF
Final_StationRelease_Mapbook.pdf PDF
INJURY_AND_ILLNESS_PREVENTION_PROGRAM_TEMPLATE.docx DOCX document
Equipment_Cleaning.docx DOCX document
SCA_77-0727.txt TXT text file
Attachment_G_JHA_2017_Station_Fire_Release.docx DOCX document
tation_Fire_Release__Inspection_form_12_12_166.doc DOC document
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Additional Emergency Fire Precautions For Angeles National Forest Construction and Service Contracts

Contract Number:

This agreement is between, West Forest, Inc. hereafter referred to as Contractor, and the USDA Forest Service, acting through the Contracting Officer, from the Angeles National Forest, hereafter referred to as Forest Service.

In accordance with the contract Fire Plan for the subject contract, Forest Service and contractor agree to the following:

In lieu of prohibiting certain operations during Project Activity Levels C and D, as required in The Contract Fire Plan, Contracting Officer agrees that Contractor may be allowed to operate subject to taking Additional Emergency Fire Precautions.

To be considered for the Additional Fire Precautions the Contractor must install a fire weather station in the contract are for obtaining Activity level records. The Forest Service shall designate the fire weather station location. Instruments needed to obtain Activity level shall meet specifications and standards in “Fire Weather Observers handbook” which is available for inspection in the District Ranger’s Office. When activity level C or above is reached, observations shall be made at 2-hour intervals, beginning not later than an hour designated by the COR. Emergency precautions for the measured Activity level shall be implemented. Records of weather measurements shall be maintained and shall be available to the Forest Service.

Level C:

For all mechanical equipment operated after 1:00 p.m. Contractor shall furnish:

1. Provide a Fire Patrol person with a 5 gallon backpack pump.

2. Fire Patrolperson at a safe distance behind each piece of equipment or patrolling with chainsaw operators.

3. Hourly re-inspection of that day’s previously treated areas.

4. For mechanized equipment or chippers charged, on-board self-actuated fire extinguishing system for each piece of subject equipment and one 10 pound 4A-60B:C fire extinguisher or equivalent, or two 10 pond 4A-60B:C fire extinguishers or equivalent on board.

5. Immediately available on contract area:

a. Portable water tank supply that meets Fire Plan specifications and capable of providing tank mixed foam approved by the Forest Service – Tank Truck requirements and is ready for immediate use. Tank supply must be either self-propelled or able to be towed by a rubber-tired skidder or crawler tractor.

Level D:

For all mechanical equipment operated between 8:00 a.m. and 1:00 p.m. no operations will be permitted after 1:00 p.m. Contractor shall furnish:

1. Provide a Fire Patrolperson with 5 gallon back pack pump.

2. Fire Patrolperson at each piece of equipment or patrolling with chainsaw operators.

3. Half-hourly re-inspection of that day’s previously treated areas.

4. For mechanized equipment or chippers charged, on-board self-actuated fire extinguishing system for each piece of subject equipment and one 10 pound 4A-60B:C fire extinguisher or equivalent, or two 10 pound 4A-60B:C fire extinguisher or equivalent on board.

4. Immediately available: (

a. Portable water tank supply that meets Fire Plan specifications – Tank Truck requirements and is ready for immediate use. Tank supply must be either self-propelled or able to be towed by a rubber-tired skidder or crawler tractor, operated by a Fire Patrolperson in communication with subject equipment and other Fire Patrolpersons on patrol and contract personnel. This water tank supply is in addition to that already required for level C.

c. Crawler tractor with dozer blade to construct fire trail.

If the Forest Service determines that the above requirements are not met, this agreement may be suspended or terminated by the Forest Service.

FOREST SERVICE Contractor:

By: Vincent Chua ___________________

Date:

Title: Contracting Officer