Attachment 3 Fire Plan.docx

DOCX document 32 KB Posted

Attached to
RECOVERY Water system replacements and upgrades Federal contract opportunity
Solicitation number
AG-9702-S-10-0238
Issued by
Department of Agriculture Forest Service Washington Office Economic Recovery Operations Center Southwest

About this file

Attachments

View the file

Other files for this federal contract opportunity

Other files attached to RECOVERY Water system replacements and upgrades, newest first.
File Type Posted
Q A.txt TXT text file
38_SF-30 Mod 1.docx DOCX document
Attachment 4 Wage Determination.docx DOCX document
Attachment 2B Map.pdf PDF
Attachment 1B Map.pdf PDF
Attachment 2D Drawings.pdf PDF
38_Solicitation.docx DOCX document
Attachment 2A Headquarters Specifications.docx DOCX document
Attachment 1A Specifications.docx DOCX document
Attachment 1E Map.pdf PDF
Attachment 2C Map.pdf PDF
Attachment 1D Drawing.pdf PDF
Attachment 1F Map.pdf PDF
Attachment 1C Map.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fire Season 2008

FIRE PLAN FOR OPERATIONS AND MAINTENANCE

Associated With *Contractor/Permit Holder*

(Ref: FSH 6309.32 and 6309.11)

1. SCOPE:

The provisions set forth below outline the responsibility for fire prevention and suppression activities and establish an attack procedure for fires within the permit area. The permit area is delineated by map in the special use permit authorizing use of National Forest system lands. The provisions set forth below also specify conditions under which permit activities will be curtailed or shut down. See Section 5, Emergency Measures below.

2. RESPONSIBILITIES:

A. Permit Holder

(1) Shall abide by the requirements of this Fire Plan.

(2) Shall take all steps necessary to prevent his/her employees, subcontractors and their employees from setting fires not required in completion of the authorized activities, shall be responsible for preventing the escape of fires set directly or indirectly as a result of Holder operations, and shall extinguish all such fires which may escape.

(3) Shall complete the Holder's Plan Regarding Personnel, Equipment and Organization (6.B) and shall furnish the Forest Service Representative (FSR) with a copy prior to commencing work at the site. Shall currently advise the FSR of any changes in personnel, equipment and organization as the changes occur. Shall revise Section 6.B to reflect current activities upon request of the FSR.

B. Forest Service

The Forest Service may conduct one or more inspections for compliance with the fire plan. The number, timing, and scope of such inspections will be committed at the discretion of agency employees responsible for fire protection administration. Such inspections do not relieve the Holder of responsibility for correcting violations of the fire plan or for fire safety in general, as outlined in paragraph 2.A above.

3. TOOLS AND EQUIPMENT:

A. The Holder shall comply with the following requirements:

Shall equip all diesel and/or gasoline-operated engines, both stationary and mobile, and all flues used in any Holder operations with spark arresters that meet Forest Service standards set forth in the National Coordinating Group publication for Multiposition Small Engines, #430-4, or General Purpose and Locomotive, #430-2. Spark arresters are not required on equipment powered by exhaust-driven turbo-charged engines or motor vehicles equipped with a maintained muffler as defined in California Public Resources Code (CPRC), Section 4442 and 4443.

Shall furnish and have available for emergency use on each piece of equipment used in conjunction with performance of the work as listed below, hand tools and/or equipment as follows (CPRC 4427, 4428 and 4431):

(a) One shovel, one axe (or pulaski) and a fully charged fire extinguisher U.L. rated at 24-10B:C, or larger, on each truck, personnel vehicle, tractor, grader and other heavy equipment.

Holder shall equip each mechanized harvesting machine with hydraulic systems, powered by an internal combustion engine (chipper, feller/buncher, harvester, forwarder, stroke delimber, etc), except tractors and skidders, with at least two 10 lb 4A/60 B-C fire extinguishers, or equivalent. In addition, concentrations of wood dust and debris shall be removed from such equipment daily.

(b) One shovel and one backpack 5 gallon water-filled tank with pump with each welder.

(c) One shovel and one pressurized chemical fire extinguisher for each gasoline-powered tool, including but not restricted to chain saws, soil augers, rock drills, etc. Fire extinguishers shall be of the type and size set forth in the California Public Resources Code Section 4431. Shovel must be kept within 100 feet from each chain saw when used off cleared landing areas.

All tools and equipment required in (1) and (2) above shall be in good workable condition and shall meet the following principle Forest Service specifications for fire tools:

(a) Shovels shall be size "O" or larger and be not less than 46 inches in overall length.

(b) Axes (or pulaskis) shall have 2-1/2 pound or larger heads and be not less than 28 inches in overall length.

Shall furnish a water tank truck or trailer, if so designated in Section 5.F. Tank truck or trailer shall be located on or immediately adjacent to the operations area and meet the following minimum specifications: contain at least 300 gallons of water; a combination straight stream-fog nozzle with 300 feet of one-inch fire hose, with no segment longer than 50 feet; fire hose with nozzle closed shall be capable of withstanding 200 psi pump pressure without leaking, slipping of couplings, distortions, or other failures; nozzle discharge rating of six to 20 gallons per minute; a pump capable of delivering 23 gallons per minute at 175 pounds psi at sea level; power unit for pump shall have fuel for at least two hours operation, with ample transport available for immediate and safe movement of tank over roads serving the operations area; and shall be in good working order; pump outlet shall be equipped with 1-1/2 inch National Standard Fire Hose thread.

Shall furnish two tractor headlights for each tractor dozer, if so designated in Section 5.G. Tractor headlights shall be attachable to each tractor and served by an adequate power source.

B. Forest Service

FSR will deliver Government-furnished fire tool box to operations site and remove after completion and acceptance of the operations, if so designated in Section 5.C below.

4. GENERAL

A. State Law. The Holder shall comply with all applicable laws of the State of California. In particular, see California Public Resource Codes.

B. Permits Required. The Holder must secure a special written permit from the District Ranger or designated representative before engaging in any of the activities listed below. The terms and conditions of any of the permits required for this operation are as shown on copies attached to the Fire Plan.

(1) Blasting and Storage of Explosives and Detonators. (Explosives Permit required by California Health & Safety Code, Section 12101.)

(2) Burning.

(3) Air Pollution. (Issued by local State or County Air Pollution Control Districts, as applicable.)

(4) Camp, Lunch and Warming Fires.

(5) Welding and Cutting.

C. Regulations for Burning. Before setting any fires whatsoever, the Holder shall notify the FSR of his/her intentions. Special care shall be taken to prevent scorching or causing any damage to adjacent structures, trees, and shrubbery. Piles of material to be burned shall be of such size and so placed that during burning no damage shall result to adjacent objects.

D. Smoking and Fire Rules. Smoking shall not be permitted during fire season, except in a barren area or in an area cleared to mineral soil at least three feet in diameter (CPRC 4423.4). In areas closed to smoking, the FSR may approve special areas to be used for smoking. Designated smoking areas shall be signed by the Holder. Holder shall post signs regarding smoking and fire rules in conspicuous places for all employees to see. Holder's supervisory personnel shall require compliance with these rules. Under no circumstances shall smoking be permitted during fire season while employees are operating light or heavy equipment, or walking or working in grass and woodlands.

E. Storage and Parking Areas. Equipment service areas, parking areas, and gas and oil storage areas shall be cleared of all inflammable material for a radius of at least 50 feet. Small mobile or stationary engine sites shall be cleared of inflammable material for a radius of at least 15 feet from such engine.

F. Welding. Holder shall confine welding activity to cleared areas having a minimum radius of ten feet measured from place of welding.

G. Blasting. Holder shall use electric caps only. When blasting is necessary in slash areas, a watchperson equipped with shovel and a water-filled backpack can (5 gallon), with hand pump, shall remain in the immediate area for an hour after blasting has been completed.

H. Oil Filter and Glass Jugs. Holder shall remove from National Forest land all oily rags and used oil filters. Holder shall prohibit use of glass bottles and jugs on authorized operations.

I. Reporting Fires. As soon as feasible, after initial control action is taken, Holder shall notify Forest Service of any fires along roads used by Holder.

J. Communications. If required in Section 5.H below, Holder shall furnish a serviceable telephone, radio-telephone, or radio system connecting each operation with the designated Forest Service Dispatch Center. A radio-equipped fire patrolperson vehicle will satisfy this requirement if in operation during the time required. The communication system shall provide prompt and reliable communications between the Holder's operations and the Forest Service Dispatch Center. The communications system shall be operable during Holder's operation in the fire precautionary period and at the time fire patrolperson service is required. The communications system shall be capable of contacting the designated Forest Service Dispatch Center within five (5) minutes of discovery of a fire in the Holder’s operating area.

5. EMERGENCY MEASURES

The table set forth below establishes work restrictions and fire precautions that the Holder must observe at each activity level.

Holder shall conform to the limitations or requirements of Project Activity Level (PAL) obtained from Forest Service before starting work each day. If practicable, Forest Service will determine the following day’s activity level by 4:00 p.m. each afternoon. Activity level may be changed at any time if, in the judgment of the Forest Service, fire danger is higher or lower than predicted and such change is consistent with forest management objectives. Whether to change the activity level and whether, when, and how to take weather observations for that purpose are within the discretion of Forest Service.

PAL applicable to this sale shall be for Fuel Model G, National Fire Danger Rating System, and Remote Automated Weather Station (RAWS) or fire danger rating area stated in the legend of Project Area Map.

PROJECT ACTIVITY LEVELS

LEVEL PROJECT ACTIVITY

A. Minimum as required by Sections 1 through 4 above.

B. Furnish Fire Patrolperson. The fire patrolperson must meet the requirements in 5.E below. When mechanized equipment with high-speed rotary head is utilized, the Fire Patrolperson shall remain in the operational area until 8:00 p.m., unless otherwise agreed in writing.

C. The following operations are prohibited from 1 p.m. until 8 p.m. local time.

a. Dead tree felling, limbing, or bucking except recently dead trees.

b. Operating high speed rotary head equipment.

c. Blasting.

D. The following operations are prohibited from 1 p.m. until 8 p.m. local time.

a. Tractor, skidder, feller-buncher (without high speed rotary head), forwarder, chipper or shovel logging operations.

b. Cable yarding with gravity operated logging systems employing non-motorized carriages when all blocks and moving lines are 10 feet or more above the ground, excluding the line between the carriage and the choker.

c. Mechanized loading and hauling, except log trucks already at the landing.

d. Hand felling green or recently dead material.

e. Power saw use at landings.

f. Welding or cutting of metal except by special permit.

g. Any other spark-emitting operation except by special permit.

The following operations are prohibited:

h. Blasting between hours of 10 a.m. and 8 p.m.

i. Cable yarding except as stated above.

j. Mechanized operations for felling (with high speed rotary head), bucking, and limbing.

k. Felling dead material.

l. Road clearing and pioneering in uncleared areas.

m. Mechanized slash disposal.

Ev. Operations are prohibited except:

a. Hauling and loading at landings.
b. Servicing of equipment at approved sites.
c. Dust abatement or rock aggregate installation for road maintenance.
d. Chainsaw operation associated with loading.

Variances are permitted for operations until 1:00 p.m. with Authorized Officer approval.

E. Operations are prohibited except:

a. Trucks at landing may be loaded and can leave sale area.

b. Equipment at landings may be serviced.

c. Roads: dust abatement or rock/aggregate installation.

All of the precautions listed above apply unless the Authorizing Officer agrees to changes in writing. Such written agreement, or substitute precautions, shall prescribe measures to be taken by Holder to reduce the risk of ignition, and/or the spread of fire.

A. The Holder can obtain the Predicted Activity level for the following day at telephone number: 530-233-8819

B. The Holder will not be required to furnish a sealed box of fire fighting tools, to be located in the operating area, at a point accessible in the event of fire. This box shall contain: one 5-gallon, backpack pump-type fire extinguisher filled with water; two axes; two Mcleod fire tools; one serviceable chain saw of three and one-half or more horsepower with a cutting bar 20 inches in length or longer; and enough shovels so that each employee at the operation can be equipped to fight fire. The box shall remain unlocked, but be sealed with a Forest Service seal to be broken for emergency use only.

C. The Forest Service will not furnish box of fire fighting tools, the contents of which is within the discretion of agency employees at the district level. The Holder shall ensure that the box remains unlocked but sealed with a Forest Service seal to be broken for emergency use only. The Holder will be responsible for keeping the box in the operating area, at a point accessible in the event of fire, and will return it to the government upon completion of the work. The Holder will be responsible for the cost of replacing any shortage of tool inventory or loss or damage to the box.

D. The Holder will be required to furnish a filled five gallon backpack pump at each work site at activity level C, or above.

E. The Holder not be required to furnish a fire patrolperson with a filled 5-gallon backpack pump to prevent, detect, and suppress any fires in the operations area. The patrolperson shall remain on duty at least two hours after the close of work, at Activity Level C, or above. SUPPLEMENT: The fire patrolperson X may (|_| may not) perform other duties on the Holder’s operations.

F. The Holder will not be required to furnish a water tank truck or trailer. Water tank truck or trailer X may (|_| may not) be used for other work on the operations.

G. The Holder will not be required to furnish tractor headlights.

H. The Holder will be required to furnish communications equipment.

(SEE TABLE ON FOLLOWING PAGE)

6. REPORTING ALL WILD FIRES

A. Holder's employees shall report all fires to any of the following Forest Service facilities and/or personnel listed below, but not necessarily in the order shown:

Name
Office Address and/or telephone
Home address and/or telephone
Dispatch Center
Dispatch Center Manager
530-233-4581
Sheriff’s Office

530-233-4416 or 911

Nearest FS Station
Engine 56 (Alturas)
530-233-8821
Fire Prevention Officer
Shannon Gurney
530-279-8330
Cell: 530-640
1st Inspector & FSR
Sean Slinkard
530-233-8823
Cell: 530-640-0064

2nd Inspector & FSR

District Ranger
Jim Irvin
530-233-8812
Cell: 530-640-0037
Contracting Officer’s Rep.
Matt Dorgan
530-233-8851
Cell: 530-233-8416

When reporting a fire, provide the following information;

Your Name;
Call back telephone number;
Project name;
Location;
Legal description (Township, Range, Section); and
Descriptive location (Reference point);
Fire Information;
Acres;
Rate of Spread; and
Wind Conditions.

B. Holder's Plan Regarding Personnel, Equipment and Organization. The Holder shall, prior to commencing work, furnish the following information relating to key personnel, tools and equipment available for the purpose of fighting wild fires within and adjacent to the operations area:

(1) Key Personnel: (In order of call preferences)

Title
Name
Address and/or telephone

Fire Supervisor

Fire Patrolperson

(2) Personnel and Equipment

Number
Classification or Type, Make & Model

Fire Fighters:

Fallers:

Power Saws:
Still
Other Equipment:
Pick-up

Fire water tank trailer

(3) Fire Suppression Plan:

The crew foreman will call every morning to obtain the Predicted Activity level at 530-233-8819.

A sealed box of fire tool including: a 5-gallon backpack sprayer, 2 axes, 2 mcleods 1 chain saw and 3 shovel for the 3 man crew.

A 500-gallon water trailer A 16 oz. can of fire kill per crew member.

The fire patrolman will have all the fire tools, the 500-gallon water trailer, a cell phone and a two way radio with him during his fire watch.

In case of a fire crew members will respond by calling 911 and use their fire suppression tools to control the fire.

Holder: Date ___________________________

Authorized Officer: Date _____________________________