Amend_001_Stand_Exam_Page_14.pdf

PDF 19 KB Posted

Attached to
Stand Examination FSVEG Update Federal contract opportunity
Solicitation number
AG-82BH-S-16-0042
Issued by
Department of Agriculture Forest Service

About this file

Amend 0001 Stand Exam Page 14

View the file

Other files for this federal contract opportunity

Other files attached to Stand Examination FSVEG Update, newest first.
File Type Posted
SF_30_Amend_0001_AG-82BH-S-16-0042.pdf PDF
Amend_001_Stand_Exam_Page_17_18.pdf PDF
Amend_001_J.2_Ex2_Specifications.pdf PDF
Stand_Exam_Section_B_to_M.pdf PDF
J.3_Ex3_Example_CSE_Data_Forms.docx DOCX document
J.5_Ex5_Polygon_Field_Verification_Form.docx DOCX document
J.7_Ex7_General_area_map.pdf PDF
J.2_Ex2_Specifications.docx DOCX document
J.9_psi_fsveg_update_cse_pts.kmz KMZ file
J.1Ex1_Stand.xlsx XLSX spreadsheet
SF_1449_AG-82BH-S-16-0042.pdf PDF
J.6_Ex6_Species_of_Concern.docx DOCX document
J.8_Stand_Map.docx DOCX document
J.4_Ex4_CSE_Inspection_Forms.docx DOCX document
J.9_kmz_Plot_Locations.docx DOCX document
J.10_Wage_Determination.txt TXT text file
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pike & San Isabel National Forests Cimarron & Comanche National Grasslands Proposed Stand Exam FSVEG Update

Solicitation Number AG-82BH-S-16-0042 Amendment Number 0001 dated August 26, 2016

A. Sample Design Form (CSE)

Contractor shall use a BAF appropriate to get a sample size of 4-8 trees per plot for overstory trees.

Contractor shall use a plot size of 1/50 (16.7’ dia.) for understory trees. It will be centered at plot center. Amendment Number 0001 add the following: A smaller fixed plot size may be used if it results in 4-8 samples per plot.

Contractor shall use a plot size of 1/50 (16.7’ dia.) to record down live and dead trees.

Amendment Number 0001 add the following: A smaller fixed plot size may be used if it results in 4- 8 samples per plot.

Contractor shall be responsible for collecting and filling out the Sample Design Form for all data items that are set to “YES” in the Required column. Contractor shall use the Sample Design form in Exhibit 2 as the template for all plots.

FIELD

NUMBER

FIELD

DESCRIPTION

REQUIRE

D

DATA

SOURCE

COMMENTS

Region Yes Government Proclaimed Forest Yes Government District Yes Government Location/Watershed

Alias Yes Site List

Stand Number Yes Site List 1 Sample Selection

Method Yes Government See Exhibit 1 –

Survey Stand List, as identified in Section J, titled List of Documents, Exhibits, and Other Attachments.

2 Sample Expansion Factor

Yes Contractor or Government

See Exhibit 1 – Survey Stand List, as identified in Section J, titled List of Documents, Exhibits, and Other Attachments.

3 Starting Azimuth Yes Contractor Collected for Brown’s

4 Subpop Filter Yes Government See Exhibit 2 – Sample Design Form, as identified in Section J, titled List of Documents, Exhibits, and Other Attachments.

File details come from the government source that posted it. Updated .