POWELL SITE
| Existing Building(s) Lighting Spreadsheet Tool - Updated Jan 20, 2010 | |||||||||||||||||||||||||||||||||||||
| Project Name: | POWELL WORK CENTER | Utility Invoice Number: | Utility Invoice Number | ||||||||||||||||||||||||||||||||||
| Dominant Building Type: | Serving Utility: | Utility Name | |||||||||||||||||||||||||||||||||||
| Space Heat Fuel Source: | Utility Contact Name: | Utility Contact Name | |||||||||||||||||||||||||||||||||||
| Customer Name | CLEARWATER FS | Utility Phone Number: | Utility Phone | ||||||||||||||||||||||||||||||||||
| Contact Name: | Energy Rate ($/kWh) & estimated $ savings/yr: | $0.05 | CUSTOMER SIMPLE PAYBACK: | ||||||||||||||||||||||||||||||||||
| Facility Street Address: | Demand Rate ($/kW) & estimated $ savings/yr: | $0.00 | 0.0 | years | This Section for Calculating PV of Periodic Lamp Replacement Cost | ||||||||||||||||||||||||||||||||
| Facility City: | Audit Prepared By (Name and Phone Number): | Auditor Info | Uses a user-defined function called dfuncPV | ||||||||||||||||||||||||||||||||||
| Facility State & Zip: | Trade Ally/Contractor Name: | Trade Ally Name | Program Parameters | ||||||||||||||||||||||||||||||||||
| Building & Account Number | Date & Time (fills in automatically): | 3/24/10 7:23 AM | |||||||||||||||||||||||||||||||||||
| Discount Rate | =dfuncPV(Number,OperatingHours,AverageLife,Cost,Labor,Labor_Rate,Discount_Rate,Measure_Life) | ||||||||||||||||||||||||||||||||||||
| Summary Table >> | Total Existing Kilowatt-Hours | Total Proposed Kilowatt-Hours | Total Estimated Annual kWh Site Savings (unadjusted) | Annual Hours (weighted) | Kilowatt-Hour Reduction Percentage | Total kWh Site Savings (adjusted for HVAC) | Measure Life | ||||||||||||||||||||||||||||||
| 79,306 | 29,108 | 50,197 | 1,282 | 63% | Labor Rate | ||||||||||||||||||||||||||||||||
| Project Cost>> | Lesser of Credit/Reimbursement -or- 0% Project Cost>> | Project Cost Cap | |||||||||||||||||||||||||||||||||||
| Location | Existing Lamp/Ballast Combination | Notes: | Proposed Lamp/Ballast Combination | Summary/Design Info | Contractor Cost | BPA Estimate Material and Labor Costs (Preliminary Only) | Existing | Proposed | |||||||||||||||||||||||||||||
| For instance; building and room name | Annual Operat Hours | Existing Lamp/Ballast | Q'ty | Watts Each | Mean Lumens Each | Total Watts | Total kWh | For high performance lamps and ballasts on the CEE list, include model numbers and CEE list date. Field notes on fixtures, mounting height, difficulty, approvals, etc… | Annual Operat Hours | Proposed Lamp/Ballast | Q'ty | Watts Each | Mean Lumens Each | Total Watts | Total kWh | Annual kWh Savings | kWh Reduction | Light Level Change | Unit | $ per unit | Total $ | Installed Cost Per Unit | Number of Units | Total | Notes | Cutsheets | Rated Average Lamp Life (hours/lamp for ballast type and start frequency) | Lamp Cost ($/lamp) | Lamp Change Labor (hours/lamp) | PV Lamp Periodic Replacement | Rated Average Lamp Life (hours/lamp for ballast type and start frequency) | Lamp Cost ($/lamp) | Lamp Change Labor (hours/lamp) | PV Lamp Periodic Replacement | Net PV Lamp Periodic Replacement (Costs(+) or Savings(-)) | ||
| 0.00 | |||||||||||||||||||||||||||||||||||||
| 1 | Old Barn (2406) | 0 | 0 | 0 | $0 | 0 | $0 | 0.00 | |||||||||||||||||||||||||||||
| 2 | Tack Shed | 1,000 | T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast | 1 | 158 | 10,181 | 158 | 158 | 1,000 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 95 | 9,071 | 95 | 95 | 63 | 40% | -11% | 1 | 8' 4LT8 Kit LBF | 1,2,3 | 12,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 3 | Tack Shed | 1,000 | Incandescent, 1-300 Watt Bulb | 2 | 300 | 4,802 | 600 | 600 | 1,000 | Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (2-F32T8) | 2 | 55 | 4,372 | 110 | 110 | 490 | 82% | -9% | 2 | New 2-lamp fixture or screw-in CFL (32-42 watts) Cost based on new fixture | 1,2,4 | 750 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 4 | Exterior Tack Shed | 500 | Incandescent, 1-200 Watt Bulb | 1 | 200 | 3,154 | 200 | 100 | 500 | High Pressure Sodium, 50W | 1 | 68 | 3,280 | 68 | 34 | 66 | 66% | 4% | 1 | Outdoor Use - Cold rated down to -20 F | 6a or 6b | 0.00 | |||||||||||||||
| 5 | Exterior Old Barn | 1 | Incandescent, 1-200 Watt Bulb | 1 | 200 | 3,154 | 200 | 0 | 1 | High Pressure Sodium, 50W | 1 | 68 | 3,280 | 68 | 0 | 0 | 66% | 4% | 1 | Existing fixture may not work - consider de-commissioning | Assume 1 hr Labor | 0.00 | |||||||||||||||
| 6 | Exterior Old Barn | 1 | Metal Halide, 150 Watt Lamp | 1 | 185 | 8,640 | 185 | 0 | 1 | No recommendation (leave fixture as-is) | 1 | 0 | 0 | 0 | 0 | 0 | 100% | -100% | 1 | No Change | 0.00 | ||||||||||||||||
| 7 | Shop/Garage (2310) | Most likely not used much (4x) 10 kW unit heaters | |||||||||||||||||||||||||||||||||||
| 8 | Mid Bay | 200 | Incandescent, 1-300 Watt Bulb | 7 | 300 | 4,802 | 2,100 | 420 | 200 | Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (2-F32T8) | 7 | 55 | 4,372 | 385 | 77 | 343 | 82% | -9% | 7 | New 2-lamp fixture or screw-in CFL (32-42 watts) Cost based on new fixture (some of the fixtures may not need to be re-lit) | 1,2,4 | 750 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 9 | Sign Bay | 200 | Incandescent, 1-300 Watt Bulb | 7 | 300 | 4,802 | 2,100 | 420 | 200 | Standard 4' T8 2 lamp 32 Watt 80+CRI lamp with Reduced Light Output ballast, (2-F32T8) | 7 | 55 | 4,372 | 385 | 77 | 343 | 82% | -9% | 7 | New 2-lamp fixture or screw-in CFL (32-42 watts) Cost based on new fixture (some of the fixtures may not need to be re-lit) | 1,2,4 | 750 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 10 | Garage | 200 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 8 | 88 | 4,868 | 704 | 141 | 200 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 8 | 48 | 4,594 | 384 | 77 | 64 | 45% | -6% | 8 | Existing fixtures too old to retrofit recommend replacement | 1,2,4 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 11 | 1313 Bldg | Cadet Wall heaters (120v/240v 750/1500 watt - 4x), single pane windows | |||||||||||||||||||||||||||||||||||
| 12 | General Interior | 1,500 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 4 | 176 | 9,736 | 704 | 1,056 | 1,500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 4 | 48 | 4,594 | 192 | 288 | 768 | 73% | -53% | 4 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 13 | Back Room | 1,500 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 360 | 1,500 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 84 | 276 | 77% | -10% | 4 | CFL screw in or hardwire GU Base - Cost based on screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 14 | Shower/Bath | 1,000 | Incandescent, 1-60 Watt Typical Bulb | 6 | 60 | 800 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | CFL screw in or hardwire GU Base - Cost based on screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 15 | Multipurpose Bldg (1401) | Baseboard Heaters (manual thermostats), Single pane windows | |||||||||||||||||||||||||||||||||||
| 16 | General Interior | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 15 | 88 | 4,868 | 1,320 | 2,640 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 15 | 48 | 4,594 | 720 | 1,440 | 1,200 | 45% | -6% | 15 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 17 | General Interior | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 5 | 176 | 9,736 | 880 | 1,760 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 5 | 48 | 4,594 | 240 | 480 | 1,280 | 73% | -53% | 5 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 18 | General Interior | Can reduce as much as 50% of lighting usage in Line 16 and 17 | 0 | Assume 30% reduction in hours | 0 | Occupancy Sensor, Timer, Photocell, or Control Panel controlling the above fixtures (50 to 200 watts) (reduce proposed operating hours accordingly) | 2 | 0 | 0 | 0 | 0 | 2 | Ceiling Mount Sensor Dual Tech Highlighted in Red for consideration only) | 8 | 0.00 | ||||||||||||||||||||||
| 19 | Multipurpose (adjacent room) | Cadet Wall Heaters (manual thermostats), Single pane windows | |||||||||||||||||||||||||||||||||||
| 20 | Multi-Purpose (adjacent room) | 1,500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 8 | 88 | 4,868 | 704 | 1,056 | 1,500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 8 | 48 | 4,594 | 384 | 576 | 480 | 45% | -6% | 8 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 21 | Restroom | 500 | Incandescent, 1-60 Watt Typical Bulb | 5 | 60 | 800 | 300 | 150 | 500 | Screw-In CFL, 14 Watt | 5 | 14 | 720 | 70 | 35 | 115 | 77% | -10% | 5 | CFL screw in or hardwire GU Base - Cost based on screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 22 | Back Room | 500 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 60 | 500 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 14 | 46 | 77% | -10% | 2 | CFL screw in or hardwire GU Base - Cost based on screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 23 | Exterior | 1,500 | Incandescent, 1-60 Watt Typical Bulb | 3 | 60 | 800 | 180 | 270 | 1,500 | Screw-In CFL, 14 Watt | 3 | 14 | 720 | 42 | 63 | 207 | 77% | -10% | 3 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 24 | Exercise Bldg (2016) | Baseboard Heaters (manual thermostats), Double pane windows | |||||||||||||||||||||||||||||||||||
| 25 | General Area | 1,500 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 3 | 176 | 9,736 | 528 | 792 | 1,500 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 95 | 9,071 | 285 | 428 | 365 | 46% | -7% | 3 | 4L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 26 | Tree Cooler Bldg (1514) | ||||||||||||||||||||||||||||||||||||
| 27 | General | 500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 88 | 500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 48 | 40 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 28 | General | 500 | T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast | 1 | 158 | 10,181 | 158 | 79 | 500 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 95 | 9,071 | 95 | 48 | 32 | 40% | -11% | 1 | 8' 4LT8 Kit LBF | 1,2,3 | 12,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 29 | Cooler | 200 | Incandescent, 1-75 Watt Typical Bulb | 5 | 75 | 1,086 | 375 | 75 | 200 | Screw-In CFL, 18 Watt | 5 | 18 | 978 | 90 | 18 | 57 | 76% | -10% | 5 | CFL screw in or new one lamp fluorescent - Cost based on screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 30 | Exterior Lighting | ||||||||||||||||||||||||||||||||||||
| 31 | Warehouse (2206) | 1 | High Pressure Sodium, 150 Watt Lamp | 6 | 185 | 8,640 | 1,110 | 1 | 1 | No recommendation (leave fixture as-is) | 6 | 0 | 0 | 0 | 0 | 1 | 100% | -100% | 6 | No Change | 0.00 | ||||||||||||||||
| 32 | Warehouse (2206) | 1 | High Pressure Sodium, 35 Watt Lamp | 1 | 62 | 2,006 | 62 | 0 | 1 | No recommendation (leave fixture as-is) | 1 | 0 | 0 | 0 | 0 | 0 | 100% | -100% | 1 | No Change | 10,000 | 0.00 | - 0 | 0.00 | 0.00 | ||||||||||||
| 33 | Fuel Depot | 4,380 | Incandescent, 1-100 Watt Typical Bulb | 5 | 100 | 1,548 | 500 | 2,190 | 4,380 | Screw-In CFL, 18 Watt | 5 | 18 | 978 | 90 | 394 | 1,796 | 82% | -37% | 5 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6 | 1,000 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 34 | Admin Bldg | 1 | High Pressure Sodium, 100 Watt Lamp | 2 | 120 | 7,790 | 240 | 0 | 1 | No recommendation (leave fixture as-is) | 2 | 0 | 0 | 0 | 0 | 0 | 100% | -100% | 2 | No Change | 0.00 | ||||||||||||||||
| 35 | Admin Flag Pole | 4,380 | Halogen, 300 Watt | 1 | 300 | 4,680 | 300 | 1,314 | 4,380 | Metal Halide Pulse Start, 150 Watt Lamp | 1 | 175 | 16,000 | 175 | 767 | 548 | 42% | 242% | 1 | Not sure of existing flag pole wattage - need more info | 6d | 1,500 | 0.00 | 12,000 | 0.00 | 0.00 | |||||||||||
| 36 | Exterior Pole Lights | 4,380 | Mercury Vapor, 400 Watt Lamp | 9 | 454 | 19,100 | 4,086 | 17,897 | 4,380 | High Pressure Sodium, 150W | 9 | 170 | 13,120 | 1,530 | 6,701 | 11,195 | 63% | -31% | 9 | Not sure of existing pole wattage - need more info | 7 | 24,000 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 37 | 1360 Bldg (Quad) | Building relatively efficient | |||||||||||||||||||||||||||||||||||
| 38 | Notes | Building has Circline Lamps in the Bedrooms with 1 40-watt and 1 32-watt circular lamps per fixture. May want to standardize to 4-ft fixtures. None of the Fluor Fixtures have electronic ballasts. | Kitchen, bedroom reading light, vanities, living room have 20-watt (2-ft) fluorescents. Again may want to standardize to a T8/electronic system. | Standardize? See notes | 10a,10b | ||||||||||||||||||||||||||||||||
| 39 | Living Room | 1,500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 264 | 1,500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 144 | 120 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 40 | Vestibule | 4,380 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 771 | 4,380 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 420 | 350 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 41 | Warehouse (2206) | Building has relatively efficient lighting - 4-ft fluorescent fixtures T8 lamps, LED exit signs. Heating a combination of electric baseboard in offices, wall heaters in hallway, 3 kw & 7.5 kw unit heaters in bays. | |||||||||||||||||||||||||||||||||||
| 42 | Alcove on main floor | 200 | T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast | 1 | 158 | 10,181 | 158 | 32 | 200 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 95 | 9,071 | 95 | 19 | 13 | 40% | -11% | 1 | 8' 4LT8 Kit LBF (no reflector needed) | 1,2,3 | 12,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 43 | Main Bay Floor | 1,500 | Metal Halide, 250 Watt Lamp | 6 | 295 | 11,300 | 1,770 | 2,655 | 1,500 | HIGH OUTPUT (high-bay) FLUORESCENT (Install New Fixture) | 6 | 153 | 0 | 918 | 1,377 | 1,278 | 48% | -100% | 6 | New high bay flourescent | 9 | 10,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 44 | Carpenter Bay | 1,500 | Metal Halide, 250 Watt Lamp | 2 | 295 | 11,300 | 590 | 885 | 1,500 | HIGH OUTPUT (high-bay) FLUORESCENT (Install New Fixture) | 2 | 153 | 0 | 306 | 459 | 426 | 48% | -100% | 2 | New high bay flourescent | 9 | 10,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 45 | Carpenter Bay | 1,500 | T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast | 3 | 158 | 10,181 | 474 | 711 | 1,500 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 95 | 9,071 | 285 | 428 | 284 | 40% | -11% | 3 | 8' 4LT8 Kit LBF | 1,2,3 | 12,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 46 | Garage | 2,000 | Metal Halide, 250 Watt Lamp | 4 | 295 | 11,300 | 1,180 | 2,360 | 2,000 | HIGH OUTPUT (high-bay) FLUORESCENT (Install New Fixture) | 4 | 153 | 0 | 612 | 1,224 | 1,136 | 48% | -100% | 4 | New high bay flourescent | 9 | 10,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 47 | Garage | 150 | T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast | 5 | 158 | 10,181 | 790 | 119 | 150 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 5 | 95 | 9,071 | 475 | 71 | 47 | 40% | -11% | 5 | 8' 4LT8 Kit LBF | 1,2,3 | 12,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 48 | Fire Cashe | 150 | Metal Halide, 250 Watt Lamp | 2 | 295 | 11,300 | 590 | 89 | 150 | HIGH OUTPUT (high-bay) FLUORESCENT (Install New Fixture) | 2 | 153 | 0 | 306 | 46 | 43 | 48% | -100% | 2 | New high bay flourescent | 9 | 10,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 49 | Fire Cashe | 1,500 | T12 8' Fluorescent, 2-75 Watt Lamps, Energy Efficient Ballast | 2 | 158 | 10,181 | 316 | 474 | 1,500 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 95 | 9,071 | 190 | 285 | 189 | 40% | -11% | 2 | 8' 4LT8 Kit LBF | 1,2,3 | 12,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 50 | Admin Bldg (2014) | ||||||||||||||||||||||||||||||||||||
| 51 | Entry | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 1 | ||||||||||||||||||||||||||||||||||
| 52 | Exit Signs throughout | 8,760 | Incandescent Exit Sign, 2-15 Watt Lamps | 6 | 30 | 2 | 180 | 1,577 | 8,760 | New LED Exit Sign | 6 | 3 | 2 | 18 | 158 | 1,419 | 90% | 0% | 6 | New LED Exit Sign | 11 | 10,000 | 0.00 | 100,000 | 0.00 | 0.00 | |||||||||||
| 53 | Reception Area | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 3 | 88 | 4,868 | 264 | 528 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 48 | 4,594 | 144 | 288 | 240 | 45% | -6% | 3 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 54 | Reception Area (Track Lighting) | 2,000 | Incandescent, 120 Watt Reflector Lamp | 5 | 120 | 1,440 | 600 | 1,200 | 2,000 | Screw-In CFL, 25 - 27 Watt | 5 | 26 | 1,488 | 130 | 260 | 940 | 78% | 3% | 5 | CFL Screw-in | 5b | 2,000 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 55 | Adjacent Office | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 3 | 88 | 4,868 | 264 | 528 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 48 | 4,594 | 144 | 288 | 240 | 45% | -6% | 3 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 56 | Adjacent Office | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 1 | 176 | 9,736 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 48 | 4,594 | 48 | 96 | 256 | 73% | -53% | 1 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 57 | Hallway | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 4 | 88 | 4,868 | 352 | 704 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 4 | 48 | 4,594 | 192 | 384 | 320 | 45% | -6% | 4 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 58 | Mens Restroom | 1,000 | T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast | 1 | 46 | 2,434 | 46 | 46 | 1,000 | High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 25 | 2,297 | 25 | 25 | 21 | 46% | -6% | 1 | 1L Reballast LBF | 1,2 (1 lamp ballast) | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 59 | Mens Restroom | 1,000 | T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast | 1 | 50 | 1,887 | 50 | 50 | 1,000 | Standard 2' T8 1 lamp 17 Watt 80+CRI lamp, (1-F17T8) | 1 | 16 | 1,103 | 16 | 16 | 34 | 68% | -42% | 1 | 1L Reballast LBF | 2, 10b (1 or 2 lp) | 9,000 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 60 | Womens Restroom | 1,000 | T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast | 1 | 46 | 2,434 | 46 | 46 | 1,000 | High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 25 | 2,297 | 25 | 25 | 21 | 46% | -6% | 1 | 1L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 61 | Womens Restroom | 1,000 | T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast | 1 | 50 | 1,887 | 50 | 50 | 1,000 | Standard 2' T8 1 lamp 17 Watt 80+CRI lamp, (1-F17T8) | 1 | 16 | 1,103 | 16 | 16 | 34 | 68% | -42% | 1 | 1L Reballast LBF | 2, 10b (1 or 2 lp) | 9,000 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 62 | Mollys Office | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 160 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 63 | Chads Office | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 4 | 88 | 4,868 | 352 | 704 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 4 | 48 | 4,594 | 192 | 384 | 320 | 45% | -6% | 4 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 64 | Computer Room | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 160 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 65 | Dougs Area | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 6 | 88 | 4,868 | 528 | 1,056 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 6 | 48 | 4,594 | 288 | 576 | 480 | 45% | -6% | 6 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 66 | Matts Office | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 160 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 67 | Marks Office | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 160 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 68 | Marks Office | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 2 | 176 | 9,736 | 352 | 704 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 512 | 73% | -53% | 2 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 69 | Across from Marks | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 160 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 70 | Next office | 2,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 3 | 88 | 4,868 | 264 | 528 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 48 | 4,594 | 144 | 288 | 240 | 45% | -6% | 3 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 71 | Fire Management | 1,000 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 5 | 88 | 4,868 | 440 | 440 | 1,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 5 | 48 | 4,594 | 240 | 240 | 200 | 45% | -6% | 5 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 72 | Track Lighting | 1,000 | Incandescent, 120 Watt Reflector Lamp | 2 | 120 | 1,440 | 240 | 240 | 1,000 | Screw-In CFL, 25 - 27 Watt | 2 | 26 | 1,488 | 52 | 52 | 188 | 78% | 3% | 2 | CFL Screw-in | 5 | 2,000 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 73 | Back Stairs | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 2 | ||||||||||||||||||||||||||||||||||
| 74 | Back Stairs | 1,000 | T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast | 2 | 50 | 1,887 | 100 | 100 | 1,000 | Standard 2' T8 1 lamp 17 Watt 80+CRI lamp, (1-F17T8) | 2 | 16 | 1,103 | 32 | 32 | 68 | 68% | -42% | 2 | 1L Reballast LBF | 2 & 10b (1 or 2 lp) | 9,000 | 0.00 | 24,000 | 0.00 | 0.00 | |||||||||||
| 75 | Front Stairs | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 1 | ||||||||||||||||||||||||||||||||||
| 76 | Upper Hallway | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 2 | 176 | 9,736 | 352 | 704 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 192 | 512 | 73% | -53% | 2 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 77 | Conference Room | 1,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 10 | 176 | 9,736 | 1,760 | 1,760 | 1,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 10 | 48 | 4,594 | 480 | 480 | 1,280 | 73% | -53% | 10 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 78 | Conference Room | 1,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 10 | 176 | 9,736 | 1,760 | 1,760 | 1,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 10 | 48 | 4,594 | 480 | 480 | 1,280 | 73% | -53% | 10 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 79 | Kitchen | 1,000 | Incandescent, 1-60 Watt Typical Bulb | 1 | 60 | 800 | 60 | 60 | 1,000 | Screw-In CFL, 14 Watt | 1 | 14 | 720 | 14 | 14 | 46 | 77% | -10% | 1 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 80 | Mens Restroom | 500 | Incandescent, 1-60 Watt Typical Bulb | 3 | 60 | 800 | 180 | 90 | 500 | Screw-In CFL, 14 Watt | 3 | 14 | 720 | 42 | 21 | 69 | 77% | -10% | 3 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 81 | Womens Restroom | 500 | Incandescent, 1-60 Watt Typical Bulb | 3 | 60 | 800 | 180 | 90 | 500 | Screw-In CFL, 14 Watt | 3 | 14 | 720 | 42 | 21 | 69 | 77% | -10% | 3 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 82 | Main General Office | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 6 | ||||||||||||||||||||||||||||||||||
| 83 | General Office | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 17 | 176 | 9,736 | 2,992 | 5,984 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 17 | 48 | 4,594 | 816 | 1,632 | 4,352 | 73% | -53% | 17 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 84 | Office | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 1 | 176 | 9,736 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 48 | 4,594 | 48 | 96 | 256 | 73% | -53% | 1 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 85 | Office | 2,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 1 | 176 | 9,736 | 176 | 352 | 2,000 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 1 | 48 | 4,594 | 48 | 96 | 256 | 73% | -53% | 1 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 86 | Upper Attic | 100 | Incandescent, 1-300 Watt Bulb | 7 | 300 | 4,802 | 2,100 | 210 | 100 | Screw-In CFL, 35 - 36 Watt (includes circline) | 7 | 36 | 1,785 | 252 | 25 | 185 | 88% | -63% | 7 | screw-in CFL (32-42 watts) | 5 | 750 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 87 | Houses (1009, 1013, 1014) | Quatities: total of all the houses (assumed similar layout) | |||||||||||||||||||||||||||||||||||
| 88 | General | 1,500 | Incandescent, 1-60 Watt Typical Bulb | 12 | 60 | 800 | 720 | 1,080 | 1,500 | Screw-In CFL, 14 Watt | 12 | 14 | 720 | 168 | 252 | 828 | 77% | -10% | 12 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 89 | General | 1,500 | Incandescent, 2-60 Watt Typical Bulbs | 9 | 120 | 1,600 | 1,080 | 1,620 | 1,500 | Screw-In CFL, 14 Watt | 18 | 14 | 720 | 252 | 378 | 1,242 | 77% | -10% | 18 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 90 | Bathroom Vanity (3 lp globe fix) | 1,000 | Incandescent, 3-60 Watt Typical Bulbs | 3 | 180 | 1,600 | 540 | 540 | 1,000 | Hard-Wired CFL, 1-32 Watt Lamp (new fixture) | 3 | 33 | 2,040 | 99 | 99 | 441 | 82% | 28% | 3 | New fixture w/F17 lamps or CFLs | 10a,10b | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 91 | House (2613) | ||||||||||||||||||||||||||||||||||||
| 92 | General | 500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 3 | 88 | 4,868 | 264 | 132 | 500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 48 | 4,594 | 144 | 72 | 60 | 45% | -6% | 3 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 93 | Bathroom Vanity (3 lp globe fix) | 300 | Incandescent, 3-40 Watt Typical Bulbs | 1 | 120 | 1,600 | 120 | 36 | 300 | Hard-Wired CFL, 1-32 Watt Lamp (new fixture) | 1 | 33 | 2,040 | 33 | 10 | 26 | 73% | 28% | 1 | New fixture w/F17 lamps or CFLs | 10a,10b | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 94 | Bathroom fan | 300 | Incandescent, 1-60 Watt Typical Bulb | 1 | 60 | 800 | 60 | 18 | 300 | Screw-In CFL, 14 Watt | 1 | 14 | 720 | 14 | 4 | 14 | 77% | -10% | 1 | CFL Screw-in (space restrictions) | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 95 | Exterior | 300 | Incandescent, 75 Watt Reflector Lamp | 1 | 75 | 801 | 75 | 23 | 300 | Screw-In CFL, 18 Watt | 1 | 18 | 978 | 18 | 5 | 17 | 76% | 22% | 1 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 2,000 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 96 | Exterior | 300 | Incandescent, 1-300 Watt Bulb | 1 | 300 | 4,802 | 300 | 90 | 300 | Screw-In CFL, 18 Watt | 1 | 18 | 978 | 18 | 5 | 85 | 94% | -80% | 1 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 750 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 97 | Houses (1335, 1334) | Quatities: total of all the houses (assumed similar layout) | |||||||||||||||||||||||||||||||||||
| 98 | Kitchen | 1,000 | T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast | 6 | 46 | 2,434 | 276 | 276 | 1,000 | High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products list. | 6 | 25 | 2,297 | 150 | 150 | 126 | 46% | -6% | 6 | 1L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 99 | Rooms (4 rooms/house) | 500 | Incandescent, 2-60 Watt Typical Bulbs | 8 | 120 | 1,600 | 960 | 480 | 500 | Screw-In CFL, 14 Watt | 16 | 14 | 720 | 224 | 112 | 368 | 77% | -10% | 16 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 100 | Rooms (4 rooms/house) reading light | 1,000 | Incandescent, 1-75 Watt Typical Bulb | 8 | 75 | 1,086 | 600 | 600 | 1,000 | Screw-In CFL, 18 Watt | 8 | 18 | 978 | 144 | 144 | 456 | 76% | -10% | 8 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 101 | Restroom vanity | 500 | T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast | 4 | 50 | 1,887 | 200 | 100 | 500 | Standard 2' T8 2 lamp 17 Watt 80+CRI lamp, (2-F17T8) | 4 | 32 | 2,206 | 128 | 64 | 36 | 36% | 17% | 4 | 2L Reballast LBF | 2,10b | 9,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 102 | Exterior | 500 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 120 | 500 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 28 | 92 | 77% | -10% | 4 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 103 | Houses (1312, 1311) | Quatities: total of all the houses (assumed similar layout) | |||||||||||||||||||||||||||||||||||
| 104 | Kitchen | 600 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 8 | 88 | 4,868 | 704 | 422 | 600 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 8 | 48 | 4,594 | 384 | 230 | 192 | 45% | -6% | 8 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 105 | Kitchen | 600 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 144 | 600 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 34 | 110 | 77% | -10% | 4 | CFL Screw-in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 106 | Hallway | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 6 | ||||||||||||||||||||||||||||||||||
| 107 | Bathroom | 300 | Standard 4' T8 2 lamp 32 Watt | 4 | 60 | 4,932 | 240 | 72 | 300 | No recommendation (leave fixture as-is) | 4 | 0 | 0 | 0 | 0 | 72 | 100% | -100% | 4 | No change | 1,2 | - 0 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 108 | Miscellaneous space | 300 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 6 | 88 | 4,868 | 528 | 158 | 300 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 6 | 48 | 4,594 | 288 | 86 | 72 | 45% | -6% | 6 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 109 | Miscellaneous space | 300 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 2 | 176 | 9,736 | 352 | 106 | 300 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 29 | 77 | 73% | -53% | 2 | Recommend delamping to 2 lamps. Reflector kit is recommended - cost based on kit | 1,2,3 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 110 | Rooms (6 Rm / house) | 600 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 12 | 88 | 4,868 | 1,056 | 634 | 600 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 12 | 48 | 4,594 | 576 | 346 | 288 | 45% | -6% | 12 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 111 | Exterior | 300 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 72 | 300 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 17 | 55 | 77% | -10% | 4 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 112 | Wash House (1604) | ||||||||||||||||||||||||||||||||||||
| 113 | General | 500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 88 | 500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 48 | 40 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 114 | General | 500 | Incandescent, 1-60 Watt Typical Bulb | 5 | 60 | 800 | 300 | 150 | 500 | Screw-In CFL, 14 Watt | 5 | 14 | 720 | 70 | 35 | 115 | 77% | -10% | 5 | Screw in - if wet location, need wet-rated bulb or fixture | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 115 | Duplex (1372) | Includes both sides - assumed similar | |||||||||||||||||||||||||||||||||||
| 116 | Kitchen | 1,500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 264 | 1,500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 144 | 120 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 117 | Garage | 500 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 60 | 500 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 14 | 46 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 118 | Bathroom (vanity) | 300 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 53 | 300 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 29 | 24 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 119 | Bedroom 1 & 2 | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 4 | ||||||||||||||||||||||||||||||||||
| 120 | Closet | 100 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 12 | 100 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 3 | 9 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 121 | Wash Closet | 500 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 60 | 500 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 14 | 46 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 122 | Stairs | 1,000 | PL lights (2 13-watt), non electronic fluorescent. Consider standardizing lamps | 4 | No recommendation (leave fixture as-is) | 4 | 4 | 2,10a,10b | |||||||||||||||||||||||||||||
| 123 | Upper Bedroom | 1,000 | PL lights (2 13-watt) , non electronic fluorescent. Consider standardizing lamps | 4 | No recommendation (leave fixture as-is) | 4 | 4 | 2,10a,10b | |||||||||||||||||||||||||||||
| 124 | Upper Storage | 100 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 24 | 100 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 6 | 18 | 77% | -10% | 4 | Screw in | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | ||||||||||||
| 125 | Exterior | 500 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 120 | 500 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 28 | 92 | 77% | -10% | 4 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 126 | Duplex (1062) | Includes both sides - assumed similar to 1372 | |||||||||||||||||||||||||||||||||||
| 127 | Kitchen | 1,500 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 264 | 1,500 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 144 | 120 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 128 | Garage | 500 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 60 | 500 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 14 | 46 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 129 | Bathroom (vanity) | 300 | T12 4' Fluorescent, 2-40 Watt Lamps, Energy Efficient Ballast | 2 | 88 | 4,868 | 176 | 53 | 300 | High Performance T8, 2-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 48 | 4,594 | 96 | 29 | 24 | 45% | -6% | 2 | 2L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 130 | Bedroom 1 & 2 | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 4 | ||||||||||||||||||||||||||||||||||
| 131 | Closet | 100 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 12 | 100 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 3 | 9 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 132 | Wash Closet | 300 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 36 | 300 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 8 | 28 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 133 | Stairs | 1,000 | PL lights (2 13-watt), non electronic fluorescent. Consider standardizing lamps | 4 | No recommendation (leave fixture as-is) | 4 | 4 | 2,10a,10b | |||||||||||||||||||||||||||||
| 134 | Upper Bedroom | 500 | PL lights (2 13-watt) , non electronic fluorescent. Consider standardizing lamps | 4 | No recommendation (leave fixture as-is) | 4 | 4 | 2,10a,10b | |||||||||||||||||||||||||||||
| 135 | Upper Storage | 100 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 24 | 100 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 6 | 18 | 77% | -10% | 4 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 136 | Exterior | 500 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 120 | 500 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 28 | 92 | 77% | -10% | 4 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 137 | Rambler House (1036) | Not sure which rambler I visited? (1006, 1036, 1046). Quantities reflect all the houses. | 0 | ||||||||||||||||||||||||||||||||||
| 138 | Living Room | 1,000 | Incandescent, 3-60 Watt Typical Bulbs | 3 | 180 | 1,600 | 540 | 540 | 1,000 | Screw-In CFL, 14 Watt | 9 | 14 | 720 | 126 | 126 | 414 | 77% | 35% | 9 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 139 | Master Bedroom | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 140 | Restroom vanity | 500 | Incandescent, 4-40 Watt Typical Bulbs | 3 | 160 | 1,610 | 480 | 240 | 500 | Standard 2' T8 2 lamp 17 Watt 80+CRI lamp, (2-F17T8) | 3 | 32 | 2,206 | 96 | 48 | 192 | 80% | 37% | 3 | New fixture w/F17 lamps or CFLs | 10a,10b | 1,500 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 141 | Bathroom fan | 500 | Incandescent, 1-60 Watt Typical Bulb | 3 | 60 | 800 | 180 | 90 | 500 | Screw-In CFL, 14 Watt | 3 | 14 | 720 | 42 | 21 | 69 | 77% | -10% | 3 | CFL Screw-in (space restrictions) | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 142 | Bedroom 2 | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 143 | Bedroom 3 | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 144 | Kitchen | 1,000 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 3 | 176 | 9,736 | 528 | 528 | 1,000 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 95 | 9,071 | 285 | 285 | 243 | 46% | -7% | 3 | 4L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 145 | Restroom vanity | 500 | Incandescent, 4-40 Watt Typical Bulbs | 3 | 160 | 1,610 | 480 | 240 | 500 | Standard 2' T8 2 lamp 17 Watt 80+CRI lamp, (2-F17T8) | 3 | 32 | 2,206 | 96 | 48 | 192 | 80% | 37% | 3 | New fixture w/F17 lamps or CFLs | 10a,10b | 1,500 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 146 | Hallway | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 3 | 10a,10b | |||||||||||||||||||||||||||||||||
| 147 | Exterior | 1,000 | Incandescent, 1-60 Watt Typical Bulb | 6 | 60 | 800 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 148 | Utility Closet | 500 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 180 | 500 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 42 | 138 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 149 | Garage | 500 | Incandescent, 1-60 Watt Typical Bulb | 9 | 60 | 800 | 540 | 270 | 500 | Screw-In CFL, 14 Watt | 9 | 14 | 720 | 126 | 63 | 207 | 77% | -10% | 9 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 150 | Triplex (1064) | Not sure which unit I visited? . Quantities only reflect all Unit. | |||||||||||||||||||||||||||||||||||
| 151 | Mechanical Room | 500 | Incandescent, 1-60 Watt Typical Bulb | 3 | 60 | 800 | 180 | 90 | 500 | Screw-In CFL, 14 Watt | 3 | 14 | 720 | 42 | 21 | 69 | 77% | -10% | 3 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 152 | Lower Floor | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 9 | ||||||||||||||||||||||||||||||||||
| 153 | Bathroom fan | 500 | Incandescent, 1-60 Watt Typical Bulb | 3 | 60 | 800 | 180 | 90 | 500 | Screw-In CFL, 14 Watt | 3 | 14 | 720 | 42 | 21 | 69 | 77% | -10% | 3 | CFL Screw-in (space restrictions) | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 154 | Kitchen | 1,500 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 3 | 176 | 9,736 | 528 | 792 | 1,500 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 95 | 9,071 | 285 | 428 | 365 | 46% | -7% | 3 | 4L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 155 | Kitchen | 1,000 | Incandescent, 3-60 Watt Typical Bulbs | 3 | 180 | 1,600 | 540 | 540 | 1,000 | Screw-In CFL, 14 Watt | 9 | 14 | 720 | 126 | 126 | 414 | 77% | 35% | 9 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 156 | Kitchen | 1,000 | T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast | 3 | 50 | 1,887 | 150 | 150 | 1,000 | Standard 2' T8 2 lamp 17 Watt 80+CRI lamp, (2-F17T8) | 3 | 32 | 2,206 | 96 | 96 | 54 | 36% | 17% | 3 | 2L Reballast LBF | 2,10b | 9,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 157 | Bathroom | 500 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 180 | 500 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 42 | 138 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 158 | Bedroom 1 | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 159 | Bedroom 2 | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 3 | 120 | 1,600 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 160 | Stairs | 500 | Incandescent, 1-60 Watt Typical Bulb | 6 | 60 | 800 | 360 | 180 | 500 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 42 | 138 | 77% | -10% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 161 | Stairs | 500 | T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast | 3 | 46 | 2,434 | 138 | 69 | 500 | High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products list. | 3 | 25 | 2,297 | 75 | 38 | 32 | 46% | -6% | 3 | 1L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 162 | Exterior | 1,000 | Incandescent, 1-65 Watt PAR Lamp | 6 | 65 | 608 | 390 | 390 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 306 | 78% | 19% | 6 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 2,000 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 163 | Duplex (1359) | Not sure which unit I visited? . Quantities only reflect all Unit. | |||||||||||||||||||||||||||||||||||
| 164 | Mechanical Room | 500 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 60 | 500 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 14 | 46 | 77% | -10% | 2 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 165 | Lower Floor | See Line 38 Bldg 1360 Circline Lamp description (1 32-watt lamp). Consider standardizing to single lamp 4-ft fixture | 6 | ||||||||||||||||||||||||||||||||||
| 166 | Bathroom fan | 500 | Incandescent, 1-60 Watt Typical Bulb | 2 | 60 | 800 | 120 | 60 | 500 | Screw-In CFL, 14 Watt | 2 | 14 | 720 | 28 | 14 | 46 | 77% | -10% | 2 | CFL Screw-in (space restrictions) | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 167 | Kitchen | 1,500 | T12 4' Fluorescent, 4-40 Watt Lamps, Energy Efficient Ballasts | 2 | 176 | 9,736 | 352 | 528 | 1,500 | High Performance T8, 4-4' lamps with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 95 | 9,071 | 190 | 285 | 243 | 46% | -7% | 2 | 4L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 168 | Kitchen | 1,000 | Incandescent, 3-60 Watt Typical Bulbs | 2 | 180 | 1,600 | 360 | 360 | 1,000 | Screw-In CFL, 14 Watt | 6 | 14 | 720 | 84 | 84 | 276 | 77% | 35% | 6 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 169 | Kitchen | 1,000 | T12 Other Fluorescent, 2-20 Watt Lamps, Magnetic Pre-Heat Ballast | 2 | 50 | 1,887 | 100 | 100 | 1,000 | Standard 2' T8 2 lamp 17 Watt 80+CRI lamp, (2-F17T8) | 2 | 32 | 2,206 | 64 | 64 | 36 | 36% | 17% | 2 | 2L Reballast LBF | 2,10b | 9,000 | 0.00 | - 0 | 0.00 | 0.00 | |||||||||||
| 170 | Bathroom | 500 | Incandescent, 2-60 Watt Typical Bulbs | 2 | 120 | 1,600 | 240 | 120 | 500 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 28 | 92 | 77% | -10% | 4 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 171 | Bedroom 1 | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 2 | 120 | 1,600 | 240 | 240 | 1,000 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 56 | 184 | 77% | -10% | 4 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 172 | Bedroom 2 | 1,000 | Incandescent, 2-60 Watt Typical Bulbs | 2 | 120 | 1,600 | 240 | 240 | 1,000 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 56 | 184 | 77% | -10% | 4 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 173 | Stairs | 500 | Incandescent, 1-60 Watt Typical Bulb | 4 | 60 | 800 | 240 | 120 | 500 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 28 | 92 | 77% | -10% | 4 | Screw in | 5 | 1,200 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| 174 | Stairs | 500 | T12 4' Fluorescent, 1-40 Watt Lamp, Energy Efficient Ballast | 2 | 46 | 2,434 | 92 | 46 | 500 | High Performance T8, 1-4' lamp with Reduced Light Output ballast. Consult CEE's qualifying products list. | 2 | 25 | 2,297 | 50 | 25 | 21 | 46% | -6% | 2 | 1L Reballast LBF | 1,2 | 20,000 | 0.00 | 30,000 | 0.00 | 0.00 | |||||||||||
| 175 | Exterior | 1,000 | Incandescent, 1-65 Watt PAR Lamp | 4 | 65 | 608 | 260 | 260 | 1,000 | Screw-In CFL, 14 Watt | 4 | 14 | 720 | 56 | 56 | 204 | 78% | 19% | 4 | Because of cold weather - CFLs not recommended unless in new enclosed fixtures - price based on new fixtures | 6c | 2,000 | 0.00 | 10,000 | 0.00 | 0.00 | |||||||||||
| TOTALS>>> | 568 | 61,843 | 79,306 | 588 | 20,498 | 29,108 | 50,197 | 0 | goes to ProjectSave | ||||||||||||||||||||||||||||
| Adding and Deleting Rows: |
To Add Rows: 1) move the curser to the number box on the left hand side of the row you want to add and left-click to highlight the row, 2) right-click in the highlighted area and choose "copy", 3) right-click again on the row number and choose "insert copied cells".
To Delete Rows: 1) move the curser to the number box on the left hand side of the row you want to add and left-click to highlight the row, 2) right-click in the highlighted area and choose "delete".
P.S. The print area on this worksheet is set so the note box does not print. The print area is set on the other worksheets as well.
&L&P&R&D, &T Add A Row Automatically copies the Existing Lamp/Ballast Combination Quantity unless user types in a changed value. For instance, type in a different value if one or more fixtures are removed or added.
Mean lamp(s) light output per existing luminaire. Does not include luminaire efficiency. Automatically draws from the Data Existing tab column D of this workbook.
Quantity of existing luminaires. User input value.
Existing watts per luminaire. Automatically draws from the Data Existing tab column C of this workbook.
These are drop-down boxes. Make a selection and it will automatically draw from the Data Existing tab column B of this workbook and populate column F, G, H, I, and J of this spreadsheet.
Estimated annual operating hours of each lighting measure (not the building). This value is user calculated and input.
Area of building, room number, location, office name, etc.. Be specific enough that someone unfamiliar with the building can easily find the room or area. You can group exact same rooms together if they have the same hours of operation and are closely located.
Must be 25% or greater in order to receive a reimbursement or credit. Font turns red if less than 25%.
Proposed watts per luminaire. Automatically drawn from the Data Proposed tab column C of this workbook.
Mean lamp(s) light output per proposed luminaire. Does not include luminaire efficiency. Automatically drawn from the Data Proposed tab column D of this workbook.
Spreadsheet automatically calculates this value. It is a per room per measure calculation.
These are drop-down boxes. Make a selection and it will automatically draw from the Data Proposed tab column B of this workbook and populate column N, O, P, and Q of this spreadsheet.
Weighted average of existing lighting system hours of operation per year.
Calculated from column Q of this worksheet. Column Q is a hidden column.
Calculated from column I of this worksheet. Column I is a hidden column.
Automatically copies the Existing Annual Operating Hours of the measure unless user types in a changed value. For instance, type in a different value if an occupancy sensor is installed.
Total Project Estimated Annual kWh savings at the site. This value is unadjusted for interactions and busbar savings. This cell sums up values in column R.
OPTIONAL: This value should be the most representative utility demand rate in dollars per kilowatt per month. You may have to average seasonal demand rates.
This cell automatically calculates the estimated dollar savings per year (12 months) associated with kW or Demand savings. This number is added to the energy savings value and put into the estimated dollar savings cell in the letter tab of this workbook.
REQUIRED: This value should be the most representative energy rate in dollars per kilowatt-hour. Usually the highest block rate in the utilities rate structure. May have to average seasonal energy rates.
This is the Reimbursement or Credit amount. Based on the total rebate amounts or 70% of project cost whichever is less. Only gives a Credit if the kWh Reduction is at least 25%.
This value is taken from the Data Proposed tab column F.
This value is the multiplication of column M and column X of this spreadsheet. It is the total reimbursement or credit per measure.
Font is RED if Wattage Reduction is NOT between 20 and 50%. The value(s) below are only related to each measure.
Font is RED if Change in Light Level is NOT between -10% and +10%. Calculates total change in light output of lamp(s) only. Ignores luminaire efficiency. Use the below value(s) to determine how close you are to the existing light level.
Per measure summary info. Use this info to check yourself.
This value is only related to the lighting kilowatt-hour reduction affected by the installation. Does not depict total building kilowatt-hour reduction percentage.
Input the project cost into the cell to the right or use the contractor bid info form to the right of this page. Includes labor and materials from the installation contractors' invoices. Also, can include in-house labor costs. Direct installation labor costs only.
This value is taken from the Data Proposed tab column E.
CAA or CRC Reimbursement or Credit per unit and total per measure Charlie Grist:
Electric Savings including estimated interactive effects of lighting and HVAC Charlie Grist:
Select building type from list. If multiple building types are present consider separate audit sheets for separate buildings. Or select the type that most closely matches the primary areas of the building where proposed lighting measures occur.
This value is used to estimate interactive effects of lighting energy savings on HVAC.
Charlie Grist:
Select dominant space heat type from list. If multiple space heat types are present, consider separate audit sheets for separate buildings. Or select the type that most closely matches the primary areas of the building where proposed lighting measures occur.
This value is used to estimate interactive effects of lighting energy savings on HVAC.
Input building for this project This value takes into account the energy…
This is the start of the file's text. The full file is on GovTribe.