Solicitation AG-6395-S-16-0193
Salient Characteristics Requirements Rad Source RS 1300 4 pi Irradiator with water chiller (brand name or equal)
X-ray irradiation system (i.e., not other sources of irradiation) o System has no radioactive source
Dual radiation chambers with turn tables
Accommodate two 5” diameter canisters 5” in height
MULTIPLE 4pi x-ray emitters to achieve dose rates up to 120 Gy/min to a 500mL canister (@ density 1)
Minimum/Maximum Dose Ratio of 1.3
Mounted on casters (or equivalent) for easy movement and cleaning
Electrical requirements are 208 VAC 3 phase, 60 HZ, 60 amp four wire (or less), L1, L2, L3, Gnd. Neutral
12 month Parts and Labor warranty, 24 month Tube warranty
Safety interlocks
Dimensions 82” length x 52” width x 42” height (or less) due to small laboratory footprint o Maximum weight 2,200 lbs
Integrates to separate external water cooling system which can be remotely located up to 50’ away, Based on a 7.5 kW/h power supply