AB_SCIEX_CESI_8000_ESI_Module_-_Product_Specifications.pdf

PDF 341 KB Posted

Attached to
CESI 8000 High Performance Separator Federal contract opportunity
Solicitation number
AG-32SD-SS-767131
Issued by
Department of Agriculture Agricultural Research Service Central Program Planning Coordination and Support

About this file

Technical Specification of CESI 8000 High Performance Separation ESI Module

View the file

Other files for this federal contract opportunity

Other files attached to CESI 8000 High Performance Separator, newest first.
File Type Posted
SSJ_CESI_8000-AB_SCIEX_LLC_VK_ _DHsigned.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USDA-AGRICULTURE RESEARCH SERVICE

TECHNICAL SPECIFICATIONS FOR CESI 8000 HIGH PERFORMANCE SEPARATION –

ESI MODULE

1.1 A98089

The CESI 8000 High Performance Separation-ESI Module consists of the first commercial CESI sprayer combined with new capillary electrophoresis instrumentation specifically designed for mass spectrometry (MS). CESI combines an intrinsically low flow CE separation with electrospray ionization (ESI) within a capillary in which the electrophoretic separation and the ESI are integrated in a single dynamic process. This gives researchers e robust, high-sensitivity interface of capillary electrophoresis

(CE) with mass spectrometry (MS) while providing a broad range of analytic coverage that is orthogonal to LC-MS and GC-MS. CE works at its best with polar and charged analytes such as small molecules, very small and large peptides often in less injection-to-injection time than LC-MS.

Molecules frequently missed or altogether undetectable by technologies, like reversed phase LC-MS. now become visible.

The CESI 8000 High Performance Separation-ESI Module includes:

• High-resolution Separation-ESI Module with sample storage temperature control (4 – 60 degree C) and capillary temperature control (15 - 30 degree C)

• Portable height adjustable electric lab bench

• System controller pre-loaded with CESI 8000 software

• System application guide

• System start-up reagents, installation and basic training

2.1 33843

CAPILLARY TEST KIT

3.1 A53537

ANION ANALYSIS KIT

The Beckman Coulter Anion Analysis Kit contains the supplies necessary for separation and quantitation of inorganic anions and organic acids using the P/ACE MDQ or PA 800 capillary electrophoresis systems. Each kit yields approximately 500 tests.

This Includes:

• Anion Coating Quantity: 38.5 ml

• Anion Separation Suffer Quantity 115.5 ml

• Conditioner -Na Quantity:38.5 ml

• Anion Acid Rinse Quantity 38.5 ml

• Anion Internal Standard Quantity 20 ml

• Anion Organic Test Mix Quantity: 3.5 ml

Anion Inorganic Test M ix Quantity:3.5 ml

• Capillaries, 50 cm. 75 µm ID Quantity: 3

· Rinse Solution Quantity: 192.5 ml

Note: A 230-nm filter is not provided with the P/ACE MDQ system. It needs to be purchased separately and installed on the system as described in the User’s Guide. The 230-nm filter is required for running the Anion Analysis Kit.

4.1 144433

FILTER, 230NM

A custom application filter that can be installed by the customer.

5.1 B07367

Silica Surface Cartridge, 30 µm ID x 90 cm total I

The OptiMS Silica Surface Cartridge is used in CESI 8000 High Performance Separation - ESI Module. It consists of a CESI cartridge coupled with the OptiMS sprayer protective housing. The assembly includes temperature controlled separation capillary (30 µm ID x 90 cm total length).

6.1 B07363

OptiMS Adapter for AB SCIEX Nanospray III source

This unique adapter is used to establish the mechanical and electrical interface between the OptiMS Assembly and the AB Sciex mass spectrometry source.

File details come from the government source that posted it. Updated .