A1-SchematicPlan-A1.1.pdf

PDF 157 KB Posted

Attached to
Jacobs Creek Dining Hall Remodel Federal contract opportunity
Solicitation number
1282A720Q0095
Issued by
Department of Agriculture Forest Service

About this file

This document includes schematic plans and specifications for a dining hall renovation project at Jacobs Creek Job Corps Civilian Conservation Center in Bristol, Tennessee. The plans detail proposed renovations to the kitchen, dishwashing area, and dining areas, including optional items to design and install new kitchen hoods; relocate the drink station, salad bar, and microwaves; and apply epoxy flooring in various rooms. The related federal contract opportunity is a solicitation from the Department of Agriculture Forest Service seeking a licensed vendor to provide design, preparation of plans and specifications, and renovation services for designated portions of the dining hall in accordance with the schematic plans. The solicitation number is 1282A720Q0095 and is titled the Jacobs Creek Dining Hall Remodel project.

View the file

Other files for this federal contract opportunity

Other files attached to Jacobs Creek Dining Hall Remodel, newest first.
File Type Posted
DiningHallBldg306All.PDF PDF
MYSCAN_20200423_0003 - Dining Hall Annex.pdf PDF
1282A720Q0095.pdf PDF
JAC-DiningHall-DB-SOW.pdf PDF
DiningHallBldg306.pdf PDF
TN20200105.pdf PDF
Solicitation 1282A720Q0095 Jacobs Creek DH.pdf PDF
JCJCC_Dining_dwgs_final.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GUEST DINING

STORAGE

SERVER

DISHWASH

OFFICE

DINING ROOM ANNEX

(AKA "SUNROOM")

KITCHEN

EMERGENCY

GENERATOR

STOR

SERVING LINE

FREEZER

VACANT

CULINARY ARTS

ADDITION

BASE ITEM: KITCHEN EPOXY FLOORING

OPTIONAL ITEM: DINING HALL/OFFICE/STORAGE ROOMS EPOXY FLOORING

Jacobs Creek Job Corps Civilian Conservaton Center

DINING HALL SCHEMATIC A1

1 1

APPROXIMATE SCALE

" = 1'

OPTIONAL ITEM:

DESIGN/BUILD RELOCATION OF DRINK STATION,

SALAD BAR, AND MICROWAVES

BASE BID: DESIGN

KITCHEN HOODS

OPTIONAL ITEM:

INSTALL HOODS

BASE BID ITEM: REMOVE TILE AND DRYWALL IN

DISHWASHING AREA. REPLACE WITH DRYWALL

AND VINYL OR STAINLESS STEEL WALL PANELS.

OPTIONAL ITEM:

PROPOSED

LOCATION OF DRINK

STATION

OPTIONAL ITEM:

PROPOSED LOCATION OF SALAD BAR, AND

MICROWAVES

AutoCAD SHX Text W

AutoCAD SHX Text W/D

AutoCAD SHX Text

MECH

AutoCAD SHX Text M

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

JAN

AutoCAD SHX Text T

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text M

AutoCAD SHX Text T

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text U

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text G

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text Sheet Title:

AutoCAD SHX Text

OF

AutoCAD SHX Text Checked:

AutoCAD SHX Text Drawn:

AutoCAD SHX Text Date:

AutoCAD SHX Text Design:

AutoCAD SHX Text Sheet:

AutoCAD SHX Text

D.VALLES

AutoCAD SHX Text 04/2020

AutoCAD SHX Text GENERAL NOTES 1. INSPECT FLOOR DRAINS AND DRAIN PIPE IN THE BUILDING AND ADDITIONS. INSPECT FLOOR DRAINS AND DRAIN PIPE IN THE BUILDING AND ADDITIONS. REPAIR/REPLACE ANY NON-FUNCTIONING DRAINAGE. 2. CONTRACTOR TO REMOVE, STORE AND REINSTALL ALL EQUIPMENT AND CONTRACTOR TO REMOVE, STORE AND REINSTALL ALL EQUIPMENT AND FURNISHINGS. EQUIPMENT CAN BE STORED IN OTHER ROOMS IN THE SAME BUILDING. 3. EXISTING FLOORING IS QUARRY TILE OVER CONCRETE SUBFLOOR. EXISTING FLOORING IS QUARRY TILE OVER CONCRETE SUBFLOOR. 4. EPOXY FLOOR TO BE SLOPED TO FLOOR DRAINS. EPOXY FLOOR TO BE SLOPED TO FLOOR DRAINS. 5. KITCHEN/DISHWASH FLOOR TO HAVE A NON-SLIP TEXTURE. KITCHEN/DISHWASH FLOOR TO HAVE A NON-SLIP TEXTURE. 6. INSTALL INTEGRAL EPOXY COVE AND BASE. HEIGHT OF BASE DEPENDENT INSTALL INTEGRAL EPOXY COVE AND BASE. HEIGHT OF BASE DEPENDENT ON HEIGHT OF REMOVED QUARRY TILE (OR OTHER) BASE. INSTALL STAINLESS STEEL TRANSITIONS/FLANGES WHERE TILE AND EPOXY ABUT. 7. KITCHEN HOOD DESIGN SHALL ALSO CONSIDER MAKE UP AIR KITCHEN HOOD DESIGN SHALL ALSO CONSIDER MAKE UP AIR REQUIREMENTS AND IMPACT ON HVAC REQUIREMENTS OF THE BUILDING. 8. RELOCATION OF DRINK STATION REQUIRES A COLD WATER CONNECTION, RELOCATION OF DRINK STATION REQUIRES A COLD WATER CONNECTION, FLOOR DRAIN AND ELECTRICAL. 9. RELOCATION OF SALAD BAR AND MICROWAVES REQUIRES ELECTRICAL. RELOCATION OF SALAD BAR AND MICROWAVES REQUIRES ELECTRICAL. 10. INSTALL STAINLESS STEEL PANEL BEHIND DISHWASHER IF VINYL PANELS INSTALL STAINLESS STEEL PANEL BEHIND DISHWASHER IF VINYL PANELS ARE THE SELECTED WALL COVERING.

Sheets and Views
A1.1
PLOT

File details come from the government source that posted it. Updated .