Salient Characteristics Special Order S20154

ULTRASONIC FLOW TRANSMITTER

SALIENT CHARACTERISTICS:

12 EA, Ultrasonic Flow Transmitter:

1. Shall have water operating temperature from at least 32 degrees F to 185 degrees F.

2. Shall have LCD with backlight.

3. Shall have end-user selectable 12 to 24 VAC or VDC external power supply.

4. Shall have at least IP54 rated enclosure.

5. Shall be an electronic transmitter.

6. Shall be capable Modbus and Pulse outputs.

7. Shall have a fully adjustable pipe range for 22mm to 115mm OD.

8. Shall have accuracy of at least +/- 1% of flow reading for greater than 0.3m/s.

9. Shall have flow velocity range of at least 0.1 to 10m/s, bidirectional.

10. Shall have universal guide rail for at least a .75" pipe.

11. Shall include I/O cable and Modbus cable that are at least 5 m long.