Salient Characteristics S20157

BANK OPERATED CABLEWAY

SALIENT CHARACTERISTICS:

4 EA, Bank Operated Cableway:

1. Shall be a remotely operated cableway system compatible for use with Acoustic Doppler Current Profiler (ADCP) systems for the purpose of streamflow discharge measurement.

2. Shall include a built-in variable speed motor and controller system.

3. Shall include a winch, with distance counter, that is capable of being attached to a standard 4” galvanized pipe.

4. Shall have a max span of at least 100 meters (328 ft.).

5. Shall have a speed drive capability of at least 0.6 m/s (2.0 ft/sec.).

6. Shall measure traversing speed with at least a 0.01 m resolution.

7. Shall include a brake to hold load (ADCP) in any position.

8. Shall include a wireless remote control capable of operating from rechargeable AA batteries or replaceable alkaline AA batteries.

9. Remote shall operate over at least 400 m via line of sight radio communication.

10. Shall have an LCD, with backlighting, display for viewing traversing measurements.

11. Cableway system shall be powered by a 12 VDC nominal power source.

366 METERS, Wire Rope:

12. Wire rope shall be at least 350 meters long that can be cut by end user to desired length.

13. Shall be 3/16 diameter, and stainless-steel wire.