Salient Characteristics S20118
FLOW THROUGH SAMPLER
SALIENT CHARACTERISTICS:
1 EA, Flow Through Sampler:
1. Must mate with existing Kuster wireline sockets, or equivalent, to the existing logging cable owned by the WSC.
2. Shall have a chamber that can be lowered in to a well and allow well fluids to pass freely through the chamber at a programmed interval.
3. Shall allow for pH range 2 to at least 9 and salinity of at least 300,000 ppm.
4. Shall be capable of atmospheric fluid transfer.
5. Shall be made of stainless steel.
6. Shall work in pressure up to at least 10,000 psi (68.9 mPa).
7. Shall have temperature range of up to at least 450°F (232°C).
8. Shall have a 60-minute programmable timer to close flow-through valve.
9. Shall have an outside diameter no larger than 1.5 in (3.81 cm).
10. Shall have a capacity of at least 1000 cc.
1 EA, Flow Through Sampler Case:
11. Shall be compatible with sampler above.