This statement of work outlines requirements for a mobile office structure for the Bureau of Land Management Elko District in Nevada. The structure must be a minimum of 16 feet wide by 40 feet long, constructed of metal, and include four offices of 92 square feet each and a central conference room of 272 square feet. Specific requirements are listed for exterior and interior finishes, doors, windows, insulation, HVAC, electrical systems, data ports, lighting, and delivery. The related federal contract opportunity is solicitation number 140L3923Q0114 for an office space in Elko, Nevada issued by the Department of the Interior Bureau of Land Management Nevada Region.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L3923Q0114.pdf | ||
| A06_Drawing.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work
BLM—Elko District Elko Air Operations Office Space with Conference Room
The BLM-Elko District would like to purchase a mobile office structure for the purpose of accommodating and providing workspace for fire and aviation program personnel in Elko, NV. The office structure must be made from metal (such as seatrain, conex container, shipping containers) for durability. This mobile office space will likely remain at the Elko Interagency Dispatch Center Airport Runway indefinitely.
Requirements:
· Entire structure should be a minimum of 16’ wide X 40’ long (New is preferred but would entertain gently used unit if it has like-new appearance once assembled)
· Exterior finish including all doors needs to be painted light tan with a rust inhibiting UV resistant paint.
· Must contain 4 office spaces 11’ 6” X 8’ (92 sq. ft.) and a conference room at least 17’ X 16’ (272 sq. ft.).
· Each office must have a door with lock.
· Must have 1 total - 36” exterior entry door that swings outward. The door must be industrial grade, door jamb must be constructed out of steel, lockable doorknob, lockable dead bolt, door closer and sweep, and painted to match the exterior. (See schematic for location)
· Must have 6 total 36”x36” horizontal sliding glass windows. Glass must be tempered, window frames constructed out of aluminum, and window jamb to be constructed out of steel. (See schematic for location)
· The container must have interior mounted insulation with a minimum insulation rating of R-11 in the walls and roof.
· The office space must include an industrial grade Air Condition / Heater Unit that is rated to service the size of the building to keep interior at a comfortable temperature. The unit must be securely fastened to the exterior. The unit must have ducting for even cooling/heating in all rooms and controlled by an interior wall mounted thermostat located in the conference room.
· All interior walls and ceiling need to be smoothly finished with sheetrock and painted with semi-gloss white paint.
· All floors must be commercial grade vinyl plank flooring.
· Must include painted door trim (tan in color) and matching vinyl baseboard molding throughout the container where appropriate.
· All electrical outlets, lights, and air handling units must terminate into an interior mounted 125 AMP-120/240VAC electrical sub-panel.
· The container must have 2 total – 120VAC waterproof exterior GFI power receptacles located near each exterior entry door.
· Must have a total of 12 - 120VAC interior duplex GFI receptacles all of which are mounted on exterior walls. (2 per office and 4 in the conference room)
· The container must have 2 total exterior lighting fixtures mounted above each entry door.
· Must have a total of 12 – ceiling mounted 48-inch 4 bulb fluorescent light fixtures. (2 per office and 4 in the conference room)
· Must have a total of 12 equally spaced network ports (CAT6) connected to a single data box mounted on the interior wall near the electrical sub-panel. (2 per office and 4 in the conference room)
· Delivery and setup must be included.
· Electrician is required to wire units to an existing disconnect (may be subcontracted).
· Ground at placement site is level and should not need any engineering.