A04.01 STATEMENT OF WORK 10761701 Rev1.pdf

PDF 121 KB Posted

Attached to
CRYOCYCLE SERVICES - SOLE SOURCE Federal contract opportunity
Solicitation number
N4523A21Q4077
Issued by
Department of the Navy Naval Supply Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to CRYOCYCLE SERVICES - SOLE SOURCE, newest first.
File Type Posted
C04.0 SOLICITATION N4523A21Q4077.pdf PDF
A04.01 CDRL A001 DETSERV 3 5997083-08242021-1 10891701.pdf PDF
C04.0 GOVERNMENT FURNISHED PROPERTY N4523A21Q4077.pdf PDF
A04.01 STATEMENT OF WORK 10891702 Rev1.pdf PDF
A04.01 STATEMENT OF WORK 10891701 Rev1.pdf PDF
A04.01 STATEMENT OF WORK 10891700 Rev1.pdf PDF
A04.01 CDRL A002 ISOCS CHARACTERIZATION 11299-08242021-2 10761701.pdf PDF
A04.01 CDRL A001 DETSERV 3W 35-TP40567A-08242021-1 10891702.pdf PDF
C04.0 DELIVERY PRICING EXHIBIT N4523A21Q4077.xlsx XLSX spreadsheet
C04.0 REPAIR PRICING EXHIBIT N4523A21Q4077.xlsx XLSX spreadsheet
A04.01 CDRL A002 ISOCS CHARACTERIZATION 5997083-08242021-2 10891701.pdf PDF
A04.01 CDRL A001 DETSERV 3 10709-08242021-1 10891700.pdf PDF
A04.01 CDRL A002 ISOCS CHARACTERIZATION 10709-08242021-2 10891700.pdf PDF
A04.01 CDRL A001 CERTIFICATE OF COMPLIANCE APEX-08242021-1 10761704.pdf PDF
A04.01 CDRL A001 DETSERV 3 11299-08242021-1 10761701.pdf PDF
A04.01 CDRL A001 CRYOSERV-CCII CRYOCYCLE-08242021-1 10761700.pdf PDF
A04.01 STATEMENT OF WORK 10761704 Rev1.pdf PDF
A04.01 CDRL A002 ISOCS CHARACTERIZATION 35-TP40567A-08242021-2 10891702.pdf PDF
A04.01 STATEMENT OF WORK 10761700 Rev1.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

Service Level 3 HPGE Detector Repair (1076-1701)

1. Background. PSNS & IMF uses High Purity Germanium (HPGE) detectors to support sample and item analyses for radioactivity.

2. Scope. Contractor will provide Service Level 3 – DETSERV-3 repair for 1 each HPGE detector (S/N 11299) including a new endcap and performing special U-Style Cryostat

Weldment repair. After the repair is complete, the contractor will perform an

ISOCS/LabSOCS Characterization – ISOXCAL to the HPGE Detector to bring it up to manufacturer’s optimum operating parameters..

3. Objective. To bring up 1 HPGE Detector (S/N 11299) to its optimum manufacturer’s operating parameters.

4. Tasks.

4.1. Service Level 3 – DETSERV-3- Standard Electrode Germanium Detector Repair:

4.1.1. Diagnosis and restoration

4.1.2. Element repair (as required)

4.2. Replacement of Detector Components

4.2.1. New end cap – Std Al with 3.75” diameter

4.3. 7094014 DSERF-SPECIAL Repair

4.3.1. U-Style Cryostat Weldment to repair damage

4.4. ISOCS Characterization

4.4.1. ISOXCAL

4.4.2. ISOCS Check source

5. Delivery. Contractor shall return a fully functional (i.e. performing at OEM optimum operating parameters and electrically cooled) furnished qty 1 ea HPGE Detector (S/N 11229) to following address after completion of tasks described above:

PSNS & IMF

RECEIVING OFFICER, BLDG 514

1400 FARRAGUT AVENUE

BREMERTON, WA 98314-5001

ATTN: JEFF FOCHTE C/2380.4R

PHONE: 360-476-3520, CELL 360-340-2766

**ADDITIONAL REQUIREMENTS.**

PRIOR TO SHIPPING, VENDOR WILL MAKE VOICE CONTACT VIA PHONE WITH

JEFF FOCHT OR HIS REPRESENTATIVE AT (360)476-3520 PSNS&IMF CODE

2380.4R WITH DATE OF SHIPMENT AND SHIPMENT TRACKING INFORMATION

(I.E. UPS/FEDEX TRACKING NUMBERS). A PHONE MESSAGE WILL NOT BE

CONSIDERED VOICE CONTACT.

NOTE: Local Technical POC for this service is David Olson, Code 105.55, (360)340-1944

Government-furnished property. Government will deliver 1 ea HPGE Detector (S/N 11299) to manufacturer.

6. Security Requirement. UNCLASSIFIED

7. Place of performance. Contractor Facility

Mirion Technologies (Canberra), Inc.

800 Research Parkway

Meriden, Connecticut, 06450