SATPC0040711 Tab 04 SOW Rev.pdf

PDF 353 KB Posted

Attached to
Modicon Schneider Electric Programmable Logic Controller (PLC) equipment Federal contract opportunity
Solicitation number
80NSSC26929072Q
Issued by
National Aeronautics and Space Administration Shared Services Center

About this file

This is a Statement of Work for the acquisition of Schneider Electric PLC automation hardware for NASA Glenn Research Center (GRC) in Cleveland, Ohio.

The requirement specifies the procurement of 28 different Schneider Electric hardware components and modules, with quantities ranging from 2 to 76 units per part number. Required items include rack systems, backplanes, power supply modules, processor modules, various input/output modules (discrete and analog), communication modules, cables, and protective covers. All hardware must be new, unused, in original packaging, and identical to currently installed equipment—refurbished items are not acceptable. The vendor must be an authorized/certified Schneider Electric Alliance Industrial Automation Distributor (IAD) and must purchase directly from Schneider Electric, not through intermediary resellers or brokers. The contractor must provide verifiable documentation of authorized distributor status, such as an official OEM authorization letter, listing on Schneider Electric's official distributor website, or documentation confirming a direct distributor relationship. The place of performance is NASA Glenn Research Center at 21000 Brookpark Road, Building 14, Room 111, Cleveland, Ohio 44135. The period of performance is 30 days from award, with delivery needed as soon as possible.

View the file

Other files for this federal contract opportunity

Other files attached to Modicon Schneider Electric Programmable Logic Controller (PLC) equipment, newest first.
File Type Posted
SATPC0040711 Tab 10 RFQ Open Market_FO.pdf PDF
SATPC0040711 Tab 10 RFQ Open Market.pdf PDF
SATPC0040711 Tab 10 BNJ_Redacted.pdf PDF
SATPC0040711 Tab 10 RFQ Open Market.pdf PDF
SATPC0040711 Tab 04 4 SOW Rev.pdf PDF
SATPC0040711 Tab 04 4 SOW.pdf PDF
SATPC0040711 Tab 07 Capability Statement Commercial.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

This requirement is for the acquisition of the Schneider Hardware for NASA Glenn Research Center (GRC). The information listed below is required to complete this purchase.

2. Characteristics, Scope, and Specs

Hardware purchased must be identical to the make and model of equipment currently in use (listed below), is new (never used) in the original packaging and not refurbished. Schneider Electric only sells PLC automation hardware through authorized distributors who can guarantee the source, condition, safety, security and warranty of the PLC automation hardware. The vendor shall be Authorized/Certified through the Schneider Electric Alliance Industrial Automation Distributor (IAD) program.

Verification in SE’s IAD and verification as an authorized distributor can be confirmed at https://www.se.com/us/en/partners/distributors/industrial-automation/.

QTY PART # ORIGINAL

EQUIPMENT

MANUFACTURER

DESCRIPTION

1 BMEXBP1002 Schneider Electric United States

SQD BMEXBP1002

RACK X80 - 10 SLOTS -

REDUNDANT PS

- ETHERNET BACKPLANE

2 BMENOC0301 Crescent Electric Supply Company

SQD BMENOC0301

ETHERNET MODULE M580

- 3-PORT

ETHERNET

COMMUNICATION

3 BMXFCW303 Schneider Electric United States

SQD BMXFCW303

CORD SET - 40-WAY

TERMINAL - TWO

ENDS FLYING LEADS -

FOR M340 I/O -

3 M

4 BMXFTW301 Schneider Electric United States

SQD BMXFTW301

FTB 20 WIRE 3M CABLE

3 BMXFTW301S Schneider Electric United States

SQD BMXFTW301S

FTB 20 WIRE 3M

SHIELDED CABLE

6 BMXFTW308S Schneider Electric United States

SQD BMXFTW308S

https://www.se.com/us/en/partners/distributors/industrial-automation/ Laura Quave Highlight

SHIELDED CORD SET - 28

WAYS

TERMINAL - ONE END

FLYING LEADS -

FOR X80 - 3 M

5 BMXFCW301S Schneider Electric United States

SQD BMXFCW301S

SHIELDED CORD SET - 40-

WAY TERMINAL - ONE

END FLYING LEADS - FOR

X80 I/O - 3 M

10 BMXXEM010 Schneider Electric United States

SQD BMXXEM010

5 PROTECTIVE COVERS

8 BMXCRA31210 Schneider Electric United States

SQD BMXCRA31210

MODICON X80 RIO DROP

E/IP

PERFORMANCE - SERVICE

PORT -

ADVANCED FEATURES

8 BMXXBP1600 Schneider Electric United States

SQD BMXXBP1600

16 SLOTS BACKPLANE

10 BMXCPS4002 Schneider Electric United States

SQD BMXCPS4002

POWER SUPPLY MODULE

X80 - 100..240 V AC

2 BMEP584040 Schneider Electric United States

SQD BMEP584040

PROCESSOR MODULE

M580 - LEVEL 4 -

REMOTE

76 BMXDAO1615 Schneider Electric United States

SQD BMXDAO1615

X80 16-CH ISOLATED

TRIAC 24-240VAC

MODUL

6 BMXAMI0810 Schneider Electric United States

SQD BMXAMI0810

ISOLATED ANALOG

INPUT MODULE X80 - 8

INPUTS - HIGH SPEED

3 BMXART0814 Schneider Electric United States

SQD BMXART0814

ANALOG INPUT MODULE

X80 - 8 INPUTS -

TEMPERATURE

3 BMXDRA1605 Schneider Electric United States

SQD BMXDRA1605

DISCRETE OUTPUT

MODULE X80 - 16

OUTPUTS - RELAY - 24 V

DC OR

24...240 V AC

3 BMXDDI3202K Schneider Electric United States

SQD BMXDDI3202K

DISCRETE INPUT MODULE

X80 - 32

INPUTS - 24 V DC

POSITIVE

3 BMXAMO0410 Schneider Electric United States

SQD BMXAMO0410

ISOLATED ANALOG

OUTPUT MODULE X80 - 4

OUTPUTS

2 BMXDAI1604 Schneider Electric United States

SQD BMXDAI1604

DISCRETE INPUT MODULE

X80 - 16

INPUTS - 100..120 V AC

CAPACITIVE

76 BMXFTW305 Schneider Electric United States

SQD BMXFTW305

X80 3-M UNSHIELDED

PREWIRED-40PT

TERMIN

3. Place of Performance

NASA GLENN RESEARCH CENTER (GRC)

21000 BROOKPARK RD

BLDG 14 RM 111

CLEVELAND, OH 44135

4. Period of Performance

30 days ARO Need by: As soon as possible

ADDITIONAL INFORMATION:

The contractor shall provide verifiable documentation demonstrating:

Current status as an authorized Schneider Electric IAD distributor Evidence that the contractor is purchasing directly from Schneider Electric, not through an intermediary reseller

Acceptable proof may include:

- Official OEM authorization letter issued to the contractor -A listing from Schneider Electric’s official distributor site showing the contractor as an authorized distributor -Documentation confirming direct distributor relationship with Schneider Electric

Restriction on Third-Party Resellers-

Resellers, brokers, or distributors that source products through another authorized distributor (i.e., third-party or pass-through vendors) shall not be considered acceptable for award.

File details come from the government source that posted it. Updated .