Lander Technologies Oxygen Liquefaction Cryogenic Cooler and Fan Specification
May 8, 2019 Rev 6 SCOPE of SUPPLY The scope of this procurement covers an integrated refrigeration system capable of providing a variable cryogenic cooling output via an indirect coolant gas supply loop. There are two applications for which the integrated refrigeration system will be used. The first application is an oxygen liquefaction application where the integrated refrigeration system will be used to liquefy oxygen gas within a tank. The integrated refrigeration system will move a working fluid (neon) through a cooling loop with one end of the cooling loop having the cold head and compressor/fan/blower and the other end being provided by NASA, a tubing heat exchanger attached to a storage tank (i.e. the indirect oxygen liquefaction application). The nominal operating pressure of the cooling loop is 100 psia and it has approximately a 0.5 psi pressure drop at the nominal flow rate of 16 g/s. The minimum design pressure for the system is 430 psig to account for isochoric heating of the process fluid from 90K to 300K. The integrated refrigeration system will connect to the NASA heat exchanger via bayonet fittings (both sides to be provided by the vendor). The second application is liquefaction of methane. The integrated refrigeration system is much less defined for this operation and can be indirect liquefaction (like the oxygen liquefaction application) or the methane gas can be provided directly to the cold head for liquefaction directly onto the cold head (direct liquefaction). In this application, the gaseous methane will be regulated down from storage bottles to between 100 and 300 psia to feed into the integrated refrigeration system. All process fluid piping shall be designed, fabricated, examined, inspected and tested in accordance the latest revision of ASME B31.3 Process Piping Code for normal fluid service and NASA NPD 8710.5, Policy for Pressure Vessels and Pressurized Systems. ASME code stamped safety relief devices shall be set, sized, and provided as required to protect the pressure systems and vessel from all credible failure scenarios as required in accordance with ASME Section VIII, Division 1 Boiler and Pressure Vessel B&PV code, ASME B31.3 code, CGA S-1.3 PRESSURE RELIEF DEVICE STANDARDS and API Recommended Practices 520 Sizing, Selection, and Installation of Pressure-Relieving Devices in Refineries and 521 Guide for Pressure Relief and Depressuring Systems.
Definition section:
Direct Liquefaction: The process fluid (methane) is in direct contact with the cold head changing the process fluid phase from gas to liquid.
Indirect Liquefaction: An intermediate working fluid (neon or helium) transports the energy from the process fluid to the cold head, changing the process fluid phase from gas to liquid.
Net pressure Gain: The allowable pressure drop across the rest of the working fluid transport loop.
Diagram for indirect oxygen liquefaction application:
1) Equipment:
Refrigeration system
2) Order Qty:
1 Integrated Cryocooling Unit
3) Process Description:
Provide 200 Watts at 90 K outlet temperature to an intermediate neon stream for indirect oxygen liquefaction application. Also, have the capability to provide a minimum of 1250 Watts at 110 K outlet temperature for either indirect methane liquefaction using neon or helium as an intermediate coolant gas, or direct methane liquefaction. Due to testing restrictions, liquid nitrogen is not to be used as a coolant in either application.
4) Fluids to be contained:
Oxygen liquefaction application - Gaseous Neon
Methane liquefaction application – Gaseous Neon, Helium, or Methane via direct liquefaction
5) Flow rate:
Oxygen liquefaction application - 16 g/s flowrate of neon for 200 W at 90K
Methane liquefaction application – Capability based
6) Fluid Interface:
1” Bayonet fittings on inlet/outlet, 2 spares
Cold unit within 10 feet of vacuum chamber
7) Nominal Operating pressure:
Oxygen liquefaction application – 100 psia
Methane liquefaction application – 100 to 300 psia
8) Max static pressure:
430 psig minimum
9) Net Pressure Gain:
Indirect oxygen liquefaction application - 0.5 psi for 16 g/s of neon at 100 psia and 90K
Methane liquefaction application – Capability based
10) Operating Temperature:
90 K to 300 K
11) Cooling Capacity:
200 W net cooling at 90 K
Minimum 1250 W net cooling at 110 K
12) Power:
3 Phase 480V AC, 60 Hz
13) Remote Operation:
Connection to allow remote PLC to control the power status (on/off) and fan/circulator speed (if applicable) as well as to pass instrumentation (requirement 14) status.
14) Instrumentation:
Differential pressure across system
Intermediate temperature between fan and cooler Other instrumentation as needed to control the integrated refrigeration system such as fan speed remotely and remote power control.
Health monitoring instrumentation
15) Heat rejection:
Facility supplied water/Dowfrost™ propylene glycol (60/40) cooling loop (only coolant available) or free/forced convection air/nitrogen.
16) Continuous Operation:
Minimum 3 months
17) Electrical Classification:
Class I Div II Group D
The unit can be split into a cold unit (cold head, circulator, etc) and warm unit (compressor, adsorber, etc), where the cold unit meets Class I Div II Group D and the warm unit is not explosion proof. In the split configuration, the warm unit must be NEMA-4X weather proof enclosure. The expected separation distance between the cold and warm unit would be approximately 100 ft. Inert purge gas is available to purge enclosures, in order to meet Class I Div II Group D requirements.
18) Footprint:
1 meter x 1 meter (not including electrical panel), skid mounted
19) Drawings:
Electronic P&ID/Schematic, Piping construction, installation, and/or fabrication drawings, Fan curves, Electrical diagrams
20) Cleanliness:
KSC-C-123 Level 300A
21) Process Piping Design:
All process piping (including the bayonets) shall be designed, fabricated, examined, inspected and tested in accordance the latest revision of ASME B31.3 Process Piping Code for normal fluid service and NASA NPD8710.5.
22) Warranty:
Vendor shall provide manufacturer’s warranty on parts of not less than 12 months from time of delivery.
22) Design Review:
A design review to be held within 30 days of award.
23) Delivery Destination:
The vendor/supplier shall include in their firm-fixed price cost proposal to the Government, FOB shipping costs of the packaged refrigeration system to the following location:
NASA Glenn Research Center
21000 Brookpark Rd Bldg 401
Cleveland, OH 44135 Note: All fittings shall be capped or plugged to maintain internal cleanliness during shipping.
24) Documentation Deliverables:
The vendor/supplier shall provide at a minimum three (3) copies of the following documentation at time of equipment delivery:
· Signed Certification of Compliance (CofC)
· Material certifications
· Installation instructions
· Cleanliness certifications / Cleanliness Acceptance Reports (as applicable)
· Visual inspection report(s)
· Non Volatile Residue (NVR) analysis report(s)
· Particulate analysis report(s)
· General System Design Documentation:
· System P&IDs
· System Component Report
· Component Cut Sheets
· Relief Devices
· Pressure Regulator s
· Pressure Vessels
· Heat Exchangers
· Dewars
· Relief Device Calculations
· Relief Device Certification Test Reports
Piping System Design & Fabrication Documentation (if applicable):
· Construction, Installation, and/or Fabrication Drawings
· Design Calculations and Specifications (per ASME B31.3)
· Mill Test Reports or Material Specifications
· Weld Procedure Specifications (WPS), Procedure Qualification Records (PQR), and Welder Performance Qualifications (WPQ)
· Inspection and NDE Reports
· Hydrostatic or Pneumatic Test Reports
· Repair or Alteration History
· Operating History
Pressure Vessel, Heat Exchanger, & Dewar Design & Fabrication Documentation (if applicable):
· Photo or Etching of Pressure Vessel Data Plate
· Manufacturer’s Data Reports (U-forms for ASME B&PV vessels)
· Fabrication Drawings
· Repair or Alteration History (R-forms for ASME B&PV vessels)
· Operating History
· Design Calculations and Specifications*
· Mill Test Reports & Impact Testing Results*
· Inspection & NDE Reports*
· Hydrostatic or Pneumatic Test Reports*
· WPS, PQR, and WPQ* ∗ For Code Stamped vessels with a valid U-form, it is possible to certify without this documentation. However, such information greatly simplifies certification and can reduce costs and prevent delays. Owners are strongly encouraged to request this documentation for new hardware whenever possible.
25) Vendor/Supplier Proposal:
The vendor/supplier shall include in their firm-fixed price response to this solicitation at a minimum the following information:
· Technical description of proposed refrigeration system
· Include any requirements on working fluid filtering or purity on the working fluids in requirement 4.
· Include any requirements for facility purges in the system to meet NEC Class I Div II Group D requirement 17.
· Measurement list of data outputs to meet requirement 14, including any purged enclosure health monitoring.
· Fabrication and Delivery schedule
· Shipping/transportation costs
· Listing of Vendor supplied Deliverables
· Any exceptions to the above government requirements as listed above in this procurement document (see items 1 – 22)
· Optional increased cost for accelerated delivery, 12-16 week after receipt of order
PAGE
Cryogenic Cooler and Fan Specification