807.pdf

PDF 84 KB Posted

Attached to
Cable Assemblies for ICBM Federal contract opportunity
Solicitation number
FA820622Q0003
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

View the file

Other files for this federal contract opportunity

Other files attached to Cable Assemblies for ICBM, newest first.
File Type Posted
FD2020-22-00022.zip ZIP file
Transportation.pdf PDF
CDRL.pdf PDF
Packaging.pdf PDF
Packaging SOW.pdf PDF
Item Description.pdf PDF
FA820622Q0003.pdf PDF
FA Report.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

1190011492069NB

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Elliott, Heidi L / 801-775-6063

6. EQUIPMENT SPEC / PHONE

Livesay, Jodi / 801-775-6566

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

X STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Hyde, Alden SNAME: 02 NOV 2021DATE:

Office: GUEA

Standard Inspection per FAR 52.246-2,-3,-4,-5 OR -6 as applicable to contract with emphasis on:

- At their discretion, gov't agency will review ATPs used in production cable testing.

- Configuration: Overall to Dwg, No Damage, Clean Finishes, Thread/Key Way Condition, No Seal material chips around sockets or pins.

- Complete Certs Package; Materials, Components, Vendor Inspection, Tests Results.

- Marking; Correct, Readable

- Packaging; Protective Caps, Individually Packaged, Sufficient Padding, Inner/Outer Package Markings Correct, Sufficient Outer Package Protecting Cables, Addressed Correctly

- Any FA or Production discrepancies Noted and Corrected

INFO

PN: 47C524855G1 CAGE: 98747 NHA: 47A524798G2

Noun: Cable Assembly, Sp Elec WP4042SS Function: Used in Testing of the CLC Dimensions: 13 inch long Cable ESD Sensitive: No Technical Order: 11N-TRV5358-1 ES Code: 46

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

C

11. SIGNATURE OF TECHNICAL AUTHORITY

Hyde, Alden S

ORGANIZATION / SYMBOL

414 SCMS / GUEAA

PHONE

801-586-6899 / 586-6899

DATE

30 NOV 2021

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 10 Dec 2021