7-Attachment C - Pricing.docx
DOCX document 21 KB Posted
- Attached to
- CDBG-DR-Basement Sanitization/HVAC State and local contract opportunity
- Solicitation number
- 541543
- Issued by
- Wayne County, Detroit City, Michigan
About this file
This is a vendor price sheet for the City of Detroit Office of Contracting and Procurement's CDBG-DR Basement Sanitization/HVAC program, which is a Community Development Block Grant-Disaster Recovery initiative under Phase 2 of the Private Sewer Repair Program. The price sheet establishes unit pricing for a comprehensive range of cleaning, sanitizing, and HVAC repair and replacement services. The scope includes labor services (supervisor and crew workers), equipment rental (turbo fans, dehumidifiers, pressure washers, wet vacs, and air scrubbers), materials (HEPA filters), debris and appliance removal, hazardous material remediation, and inspections and repairs for HVAC systems, hot water tanks, furnaces, and boilers. Specific line items detail furnace replacement with Energy Star rated 96% efficiency gas-fired forced air units, boiler replacement with new thermostats and feeder systems, and asbestos-containing material removal from cellar ducts in accordance with applicable law.
The pricing structure is based on hourly rates for labor and equipment services, per-unit pricing for materials and appliance removals, per-load pricing for hazardous material remediation, and per-linear-foot pricing for piping repairs and asbestos abatement. The furnace and boiler replacement line items include comprehensive installation requirements with specific efficiency ratings and inspection protocols. Hot water heater installations are available in both standard and power-vented configurations, each Energy Star certified and sized up to 40 gallons, with elevated installation available as a change order option. All pricing is to be submitted by vendors as part of their proposal response to the City of Detroit for consideration in this CDBG-DR funded program.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| 10-Combined Corporate Accountability and Workforce Safety Affidavit 3-21-2024 FINAL.docx | DOCX document | |
| 6-SAM.gov-prevailing wage.pdf | ||
| 2-Attachment E - Professional Service Contract Sample.docx | DOCX document | |
| 8-Equalization Credit Statement.pdf | ||
| 9-RFQ 541543.pdf | ||
| 5-EMPLOYEE RIGHTS ON GOVERNMENT CONTRACTS.pdf | ||
| 3-Attachment D-2 - Conditions of Award.pdf | ||
| 1-Attachment D-1 Required Forms Affidavits.pdf | ||
| 4-Attachment A - Respondent Questionnaire.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vendor Price Sheet for Cleaning/Sanitizing/HVAC Repair
Vendor Price Sheet average for Cleaning/Sanitizing/HVAC Repair
Item Number
| Description |
| Estimated Quantity |
| Unit of Measure |
| Unit Price |
| Extended Unit |
Price
| 1 |
| Supervisor |
| 1 |
| Hour |
| 2 |
| Crew Worker |
| 1 |
| Hour |
| 3 |
| Additional Crew Worker |
| 1 |
| Hour |
| 4 |
| Turbo Fan |
| 1 |
| Hour |
| 5 |
| Dehumidifier |
| 1 |
| Hour |
| 6 | |||
| Pressure | Washer | with | Self- |
Contained Water Supply
| 1 |
| Hour |
| 7 |
| WetVac |
| 1 |
| Hour |
| 8 |
| HEPA 3 Filter |
| 1 |
| Each |
| 9 |
| Air Scrubber |
| 1 |
| Each |
| 10 |
| Debris Removal (curb) |
| 1 |
| Hour |
| 11 |
| Appliance Removal |
| 1 |
| Hour |
| 12 |
| Hazardous Material |
Remediation
| 1 |
| Load |
| 13 |
| HVAC inspection |
| 1 |
| Hour |
| 14 |
| HVAC repair |
| 1 |
| Hour |
| 15 |
| Hot Water Tank inspection |
| 1 |
| Hour |
| 16 |
| Hot Water Tank |
| 1 |
| Hour |
| 17 |
| Furnace Replacement: Remove the existing furnace and install a new Energy Star Rated 96% efficiency gas fired forced air furnace. This cost includes the condensation pump with a tube running over to the laundry tub. (No PVC tube creating a trip hazard) Change Order or additional fee request at contractor walk through for furnace to be elevated. Contractor to verify appropriate BTU sizing prior to install |
| 1 |
| Each |
| 18 |
| Boiler Repair |
| 1 |
| Hour |
| 19 |
| Boiler Replacement: Remove the existing boiler and install a new steam boiler. To include new thermostat. Cost covers up to 170K BTU Size. Feeder must be included and a leak test must be conducted after installation. The inspection of all radiators and valves must be conducted prior to BSEED Inspection |
| 1 |
| Each |
| 20 |
| Repair boiler steam supply piping Approx _____ Lnft. |
Per LF
| 21 |
| Existing ducts in cellar are covered with what appears to be asbestos containing material. All asbestos containing material shall be removed and disposed according to law. |
Per LF
| 22 |
| Install a new gas fired hot water heater. Must be Energy Star Certified and cost covers up to 40-Gallons. |
| 1 |
| Each |
| 23 |
| Install a new power vented gas fired hot water heater. Must be Energy Star Certified and cost covers up to 40-Gallons. Request to have elevated will be issued via change order or at time of contractor walk through |
| 1 |
| Each |
File details come from the government source that posted it. Updated .