DEWATERING_PIT_WIRING_DIAGRAM.pdf
PDF 210 KB Posted
- Attached to
- Dewatering Pit Pump Control Panels Federal contract opportunity
- Solicitation number
- 6923G519BPANELS
About this file
Drawing E-001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30_Amendment_A001_6923G519BPANELS.pdf | ||
| DEWATERING_PUMP_NO.1_AND_NO.2_MCC_ELECTRICAL_SCHEMATIC.pdf | ||
| RFQ_Dewatering_Pit_Control_Panels.pdf | ||
| SECTION_26_0100_-_Special_Conditions.doc | DOC document | |
| DEWATERING_PUMP_NO.3_MCC_ELECTRICAL_SCHEMATIC.pdf | ||
| WAGE_DETERMINATION_PIT_PANEL.pdf | ||
| SECTION_26_0914_-_Dewatering_Pit_Pump_Control_System.doc | DOC document | |
| DEWATERING_PUMPS_SENSOR_AND_CONTROLS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEWATERING PIT
DOWNSTREAM SPREADER ROOM
PUMP 1
PUMP 2 PUMP 3
MOTOR CONTROL CENTER
PUMP 1
PUMP 2
PUMP 3
ELECTRIC
MANHOLE
ELECTRIC
MANHOLE
PROPOSED
DPCP
TIMEMARK
JUNCTION
BOX
JUNCTION
BOX
EXISTING CONTROL WIRING
PROPOSED CONTROL
WIRING
EXISTING CONDUIT AND
WIRING SYSTEM
PROPOSED
DPCP
REMOTE
OIU
TIMEMARK
PROPOSED
TRANSDUCER
AND
CABLE
PROPOSED PVC
WEATHERPROOF JB
H-O-A
E-STOP
PANEL
PLC
CABINET
GENERAL NOTES:
1. DRAWING IS DIAGRAMMATIC ONLY FOR THE PURPOSE OF ILLUSTRATING INTENT. ACTUAL FIELD LOCATIONS AND DISTANCES SHALL BE
VERIFIED BY THE CONTRACTOR.
2. ALL PROPOSED EQUIPMENT LOCATIONS SHALL BE COORDINATED WITH SLSDC PRIOR TO INSTALLATION.
3. DEMOLITION SHALL INCLUDED ALL EXISTING TIMEMARK LIQUID LEVEL CONTROLS SYSTEM, RELATED FIELD DEVICES AND WIRING.
4. PROPOSED EQUIPMENT SHALL INCLUDE DEWATERING PIT CONTROL PANEL( DPCP), DPCP REMOTE OIU, LEVEL TRANSDUCER AND ALL
RELATED WIRING.
5. CONTRACTOR SHALL COORDINATE ALL WIRING REQUIREMENTS WITH DPCP SUPPLIER.
6. EXISTING CONTROL WIRING FROM DEWATERING PIT JUNCTION BOX TO SPREADER ROOM JUNCTION BOX SHALL BE REUSED.
CONTRACTOR SHALL INSTALL TWO (2) ETHERNET CABLES AND TWO (2) TRANSDUCER CABLES FROM DEWATERING PIT TO SPREADER
ROOM THROUGH EXISTING CONDUIT SYSTEM. OUTER CABLE JACKET SHALL BE RATED FOR DIRECT BURIAL.
7. CONTRACTOR SHALL INSTALL ALL NEW CONTROL WIRING IN SPREADER ROOM AS REQUIRED BETWEEN MOTOR CONTROL CENTER, PLC
CABINET, SPREADER ROOM JUNCTION BOX AND DPCP.
8. IN THIS DRAWING PUMP 3 IS SHOWN AS BEING FED FROM THE EXISTING MOTOR CONTROL CENTER, THAT LOCATION MAY CHANGE TO A
SEPARATELY WALL MOUNTED UNIT LOCATED IN THE SPREADER ROOM. CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE
INSTALL, AT NO ADDITIONAL COST, REGARDLESS OF FINAL LOCATION.
9. DISTANCE BETWEEN DEWATERING PIT AND SPREADER ROOM IS UNDER THREE HUNDRED FEET.
120V
120V TO
LIGHTING PANEL
AutoCAD SHX Text
DEWATERING PIT LIQUID LEVEL CONTROL WIRING DETAIL
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AutoCAD SHX Text
NONE
AutoCAD SHX Text 1=1
AutoCAD SHX Text
AutoCAD SHX Text 8/28/19
AutoCAD SHX Text E-001
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
| Sheets and Views |
| DEWATERING PIT WIRING DIAGRAM-Model |