UPDATED_CLIN_STRUCTURE_6309R3281207.docx
DOCX document 19 KB Posted
- Attached to
- Clean UV Modules Federal contract opportunity
- Solicitation number
- 6309R3281207
About this file
UPDATED quantities on CLIN structure
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| UV_scope.pdf | ||
| Nogales_WD.pdf | ||
| CLIN_STRUCTURE_6309R3281207.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIN STRUCTURE 6309R3281207
| CLIN |
| Description |
| Qty |
| Unit |
| Unit Price |
| Total Price |
| 001 |
| BASE PERIOD |
On a quarterly basis, provide all labor, tools, equipment, and services for removing, cleaning and reinstalling on site all Ultra Violet Modules in the Ultra Violet Disinfection System at the Nogales International Wastewater Treatment Plant (NIWTP) in accordance with the manufacturer's recommendations. The system includes six banks of 22 modules with each module containing eight lamps, and four ballasts.
Work shall be performed as a single project and include the following:
a. Submit a proposed work plan for the review and approval of the IBWC prior to the proceeding of the work;
b. Remove modules out of each channel one bank at a time;
c. Inspect and, if required, remove debris from module using a low pressure washer, wipes and hand brushing;
d. Record any damaged lamps or quartz sleeves, and report to IBWC;
e. Remove damaged lamps and quartz sleeves and replace as required;
f. Top up the wiper collars with ActiClean Gel as required;
g. Install modules back into the channel;
h. Carry out checks and start up procedures to place system back in operation.
Period of Performance: 08/01/2016-09/30/2016
| 1 |
| EA |
| 002 |
| BASE PERIOD |
Replace damaged lamps; this is an estimated amount.
Period of Performance: 08/01/2016-09/30/2016
| 50 |
| EA |
| 003 |
| BASE PERIOD |
Replace damaged quartz sleeves; this is an estimated amount.
Period of Performance: 08/01/2016-09/30/2016
| 50 |
| EA |
| 004 |
| BASE PERIOD |
On a yearly basis flush and clean entire cleaning system and replace ActiClean Gel Lead Technician overseeing the work shall be certified by Aquafme/Trojan.
Period of Performance: 08/01/2016-09/30/2016
| 1 |
| EA |
| 005 |
| OPTION YEAR ONE |
On a quarterly basis, provide all labor, tools, equipment, and services for removing, cleaning and reinstalling on site all Ultra Violet Modules in the Ultra Violet Disinfection System at the Nogales International Wastewater Treatment Plant (NIWTP) in accordance with the manufacturer's recommendations. The system includes six banks of 22 modules with each module containing eight lamps, and four ballasts.
Work shall be performed as a single project and include the following:
a. Submit a proposed work plan for the review and approval of the IBWC prior to the proceeding of the work;
b. Remove modules out of each channel one bank at a time;
c. Inspect and, if required, remove debris from module using a low pressure washer, wipes and hand brushing;
d. Record any damaged lamps or quartz sleeves, and report to IBWC;
e. Remove damaged lamps and quartz sleeves and replace as required;
f. Top up the wiper collars with ActiClean Gel as required;
g. Install modules back into the channel;
h. Carry out checks and start up procedures to place system back in operation.
Period of Performance: 10/01/2016-09/30/2017
| 4 |
| EA |
| 006 |
| OPTION YEAR ONE |
Replace damaged lamps; this is an estimated amount Period of Performance: 10/01/2016-09/30/2017
| 100 |
| EA |
| 007 |
| OPTION YEAR ONE |
Replace damaged quartz sleeves.
Period of Performance: 10/01/2016-09/30/2017
| 100 |
| EA |
| 008 |
| OPTION YEAR ONE |
On a yearly basis flush and clean entire cleaning system and replace ActiClean Gel Lead Technician overseeing the work shall be certified by Aquafme/Trojan.
Period of Performance: 10/01/2016-09/30/2017
| 1 |
| EA |
| 009 |
| OPTION YEAR TWO |
On a quarterly basis, provide all labor, tools, equipment, and services for removing, cleaning and reinstalling on site all Ultra Violet Modules in the Ultra Violet Disinfection System at the Nogales International Wastewater Treatment Plant (NIWTP) in accordance with the manufacturer's recommendations. The system includes six banks of 22 modules with each module containing eight lamps, and four ballasts.
Work shall be performed as a single project and include the following:
a. Submit a proposed work plan for the review and approval of the IBWC prior to the proceeding of the work;
b. Remove modules out of each channel one bank at a time;
c. Inspect and, if required, remove debris from module using a low pressure washer, wipes and hand brushing;
d. Record any damaged lamps or quartz sleeves, and report to IBWC;
e. Remove damaged lamps and quartz sleeves and replace as required;
f. Top up the wiper collars with ActiClean Gel as required;
g. Install modules back into the channel;
h. Carry out checks and start up procedures to place system back in operation.
Period of Performance: 10/01/2017-09/30/2018
| 4 |
| EA |
| 010 |
| OPTION YEAR TWO |
Replace damaged lamps; this is an estimated amount Period of Performance: 10/01/2017-09/30/2018
| 100 |
| EA |
| 011 |
| OPTION YEAR TWO |
Replace damaged quartz sleeves; this is an estimated amount Period of Performance: 10/01/2017-09/30/2018
| 100 |
| EA |
| 012 |
| OPTION YEAR TWO |
On a yearly basis flush and clean entire cleaning system and replace ActiClean Gel Lead Technician overseeing the work shall be certified by Aquafme/Trojan.
Period of Performance: 10/01/2017-09/30/2018
| 1 |
| EA |
| 013 |
| OPTION YEAR THREE |
On a quarterly basis, provide all labor, tools, equipment, and services for removing, cleaning and reinstalling on site all Ultra Violet Modules in the Ultra Violet Disinfection System at the Nogales International Wastewater Treatment Plant (NIWTP) in accordance with the manufacturer's recommendations. The system includes six banks of 22 modules with each module containing eight lamps, and four ballasts.
Work shall be performed as a single project and include the following:
a. Submit a proposed work plan for the review and approval of the IBWC prior to the proceeding of the work;
b. Remove modules out of each channel one bank at a time;
c. Inspect and, if required, remove debris from module using a low pressure washer, wipes and hand brushing;
d. Record any damaged lamps or quartz sleeves, and report to IBWC;
e. Remove damaged lamps and quartz sleeves and replace as required;
f. Top up the wiper collars with ActiClean Gel as required;
g. Install modules back into the channel;
h. Carry out checks and start up procedures to place system back in operation.
Period of Performance: 10/01/2018-09/30/2019
| 4 |
| EA |
| 014 |
| OPTION YEAR THREE |
Replace damaged lamps; this is an estimated amount Period of Performance: 10/01/2018-09/30/2019
| 100 |
| EA |
| 015 |
| OPTION YEAR THREE |
Replace damaged quartz sleeves; this is an estimated amount.
Period of Performance: 10/01/2018-09/30/2019
| 100 |
| EA |
| 016 |
| OPTION YEAR THREE |
On a yearly basis flush and clean entire cleaning system and replace ActiClean Gel Lead Technician overseeing the work shall be certified by Aquafme/Trojan.
Period of Performance: 10/01/2018-09/30/2019
| 1 |
| EA |
| 017 |
| OPTION YEAR FOUR |
On a quarterly basis, provide all labor, tools, equipment, and services for removing, cleaning and reinstalling on site all Ultra Violet Modules in the Ultra Violet Disinfection System at the Nogales International Wastewater Treatment Plant (NIWTP) in accordance with the manufacturer's recommendations. The system includes six banks of 22 modules with each module containing eight lamps, and four ballasts.
Work shall be performed as a single project and include the following:
a. Submit a proposed work plan for the review and approval of the IBWC prior to the proceeding of the work;
b. Remove modules out of each channel one bank at a time;
c. Inspect and, if required, remove debris from module using a low pressure washer, wipes and hand brushing;
d. Record any damaged lamps or quartz sleeves, and report to IBWC;
e. Remove damaged lamps and quartz sleeves and replace as required;
f. Top up the wiper collars with ActiClean Gel as required;
g. Install modules back into the channel;
h. Carry out checks and start up procedures to place system back in operation.
Period of Performance: 10/01/2019-09/30/2020
| 4 |
| EA |
| 018 |
| OPTION YEAR FOUR |
Replace damaged lamps; this is an estimated amount Period of Performance: 10/01/2019-09/30/2020
| 019 |
| OPTION YEAR FOUR |
Replace damaged quartz sleeves; this is an estimated amount
| 020 |
| OPTION YEAR FOUR |
On a yearly basis flush and clean entire cleaning system and replace ActiClean Gel Lead Technician overseeing the work shall be certified by Aquafme/Trojan.
TOTAL