40961054 mfg specs.pdf

PDF 357 KB Posted

Attached to
FILTER ASSEMBLY Federal contract opportunity
Solicitation number
SPMYM224Q1652
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document is a product specification for the Kaydon Model 981 Filtration Assembly, which is a pressure or return line filter for oil and fuel filtration applications. The specification details the assembly's technical specifications, including flow rates, pressure ratings, materials of construction, differential pressure indicator, and replacement filtration elements. It also includes pressure drop curves for various fluid viscosities and micron ratings.

The related federal contract opportunity is a solicitation from the Defense Logistics Agency Land and Maritime for a "Filter Assembly." The solicitation is a HUBZone set-aside, and electronic submission of quotes is available through the SAM website. Contractors required to implement NIST SP 800-171 must have a current assessment, but COTS items are exempt from this requirement. Bids must include a signed and completed solicitation, and contractors must check the applicable boxes in clause 52.204-24.

View the file

Other files for this federal contract opportunity

Other files attached to FILTER ASSEMBLY, newest first.
File Type Posted
2ND AMENDED SOLICITATION SPMYM224Q1652.pdf PDF
AMENDED SOLICITATION SPMYM224Q1652.pdf PDF
SOLICITATION SPMYM224Q1652.pdf PDF
SOLE SOURCE_Redacted.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Kaydon Model 981 Filtration Assembly is a durable and robust inline pressure or return line (1,200 psig maximum) filter assembly used for oil and fuel filtration applications. The Model 981 is rated for a maximum of 40 gpm for oils and diesel fuel {check pressure drop curves to determine initial (clean) pressure drops for your flow and viscosity}. The Model 981 uses the KMP 9600 series (8 inch length) elements with media selection of 1, 3, 6, 12 and 25 microns. The Model 981 is suitable for use with hydraulic systems used in mobile equipment, small industrial hydraulic power units, small lube systems, and diesel fuel transfer where larger filtration assemblies are not practical. The Model 981 is a substitute for spin‐on type filters where extra protection and a more rugged design is desired. The inlet/outlet connections are 1.5 inch NPTF, so flow restriction is reduced, plus the internal flow path provides low pressure drop (flow resistance). A visual “pop‐up” differential pressure indicator is provided to notify an operator for element replacement. Bowl removal is made easier with a “hand grip” to help twist the bowl from filter head. A safety by‐pass valve set at 50 psid ensures protection of the element and helps maintain flow before element change ‐out is required. Mounting is simplified with four mounting holes (see drawing and photo for location and size). The housing is aluminum construction, making it lightweight, plus the bowl is anodized to protect against corrosion.

Specifications

Flows Up To 40 GPM / 152 lpm Inlet and Outlet Connections 1‐1/2 inch NPTF Seal Material and Type Material: Fluoroelastomer Type: Circumferential Bowl Seal Material of Construction Head: Die Cast Aluminum Bowl: Anodized Die Cast Aluminum By‐Pass Valve: Nylon Filtration Element: Tin coated carbon steel end caps and center tube. Epoxy adhesives and inert micro‐fiberglass filtration media.

Fluid Compatibility Petroleum Based Fluids (maximum viscosity = ISO 320) Max. Operating Pressure / Static Burst Pressure 1,200 psig (83 bar) / 3,000 psig (206 bar) Rated Fatigue Pressure 0—1000—0 psig for 1,000,000 cycles Application Inline Oil Filtration or Return Line Oil Filtration (maximum viscosity = ISO 320) Recommended Change‐Out Differential Pressure 25 psid (1.7 bar) Differential Pressure Indicator Type and Setting Type: Visual — mechanical “pop‐up” type indicator with Fluoroelastomer seal. Setting = 44 psid By‐Pass Valve Rating 50 psid (3.4 bar) Operating Temperature Range ‐15F — 250 F (‐26C—120C) Replacement Filtration Elements 8 inch (204 mm) length elements Replacement Filtration Element Ratings βx = 200: 1, 3, 6, 12, or 25 μ / βx(c) = 1000: 3, 5, 7, 12, 22 μ Assembly Weight

8.8 pounds (4 kg)

SEAL KIT

Part Number 981‐SEAKKIT (includes o‐ring bowl seal)

NOTE

Filtration Element not included. Order separate.

981 Filtration Assembly

11.1 inches

8.5 inches

Kaydon Custom Filtration Corporation 1571 Lukken Industrial Drive West

LaGrange, Georgia, 30240 U.S.A.

1-800-241-2342 / 1-706-884-3041

©2014 Kaydon Filtration - PRINTED IN USA

DS981-061614(REV. 1)

981 Filtration Assembly Part Number Structure

Part Number Example: 981-1.5-08-V-44-50-V

0 6 12 24 Flow — Gallons per Minute

Pr es su re

D ro p p si d

Element KMP9600AKC8 — 1μ Pressure Drop versus Flow

ISO 220 ISO 150 ISO 100

ISO 68

ISO 32

0 8 16 32 Flow — Gallons per Minute

Pr es su re

D ro p p si d

Element KMP9600AKF8 — 3μ

ISO 220 ISO 150

ISO 100

ISO 68

ISO 32

0 10 20 40 Flow — Gallons per Minute

Pr es su re

D ro p p si d

Element KMP9600AKH8 — 6μ

ISO 220 ISO 150

ISO 100

ISO 68

ISO 32

Pressure Drop Curves

Model

981 Inlet and Outlet Ports Element Length DP Indicator Setting

1.5 = 1-1/2 inch NPTF

V = Fluoroelastomer

08 = 8 inches 44 = 44 psid Indicator

By-Pass Valve Seal Material

50 = 50 psid

0 10 15 40

Flow — Gallons per Minute

Pr es su re

D ro p p si d

981 Filter Housing

1-1/2” Ports

0 10 20 40 Flow — Gallons per Minute

Pr es su re

D ro p p si d

Element KMP9600AKM8 — 12μ

ISO 220

ISO 150

ISO 100

ISO 68

ISO 32

0 10 20 40 Flow — Gallons per Minute

Pr es su re

D ro p p si d Element KMP9600AKR8 — 25μ

ISO 220

ISO 150

ISO 100

ISO 68

ISO 32

diesel fuel

ISO 320

diesel fuel

ISO 320

diesel fuel

ISO 320

diesel fuel

ISO 320

diesel fuel

ISO 320

Pressure Drop Calculation

1. Determine your flow rate in GPM (gallon per minute)

2. Determine your fluid viscosity in ISO (cSt is same as ISO)

3. Determine element (micron rating) you choose to use for your application

4. With flow, viscosity, and element information, use the appro-priate chart to find the initial (clean) pressure drop,

5. After pressure drop is determined for the element, use 981

Filter Housing chart to determine housing pressure drop.

6. Add element pressure drop and housing pressure drop to calculate total initial (clean) pressure drop.

7. Total initial (clean) pressure drop should =/< 6 psid.

EXAMPLE: Pressure Drop Calculation

1. Flow Rate = 30 gpm

2. Viscosity = ISO 32 (32 cSt)

3. 12 micron element (KMP9600AKM8)

4. Initial (clean) pressure drop (element) = 3 psid

5. Initial (clean) pressure drop (housing) = 1.5 psid.

6. Total initial (clean) pressure drop = 3 psid (element)

+ 1.5 psid (housing) = 4.5 psid (total).

DP Indicator

V = Visual Mechanical “Pop-Up” Type

981 Filtration Assembly

Kaydon Custom Filtration Corporation 1571 Lukken Industrial Drive West

LaGrange, Georgia, 30240 U.S.A.

1-800-241-2342 / 1-706-884-3041

©2014 Kaydon Filtration - PRINTED IN USA

DS980-0612014(REV. 0)

Differential Pressure Indicator (mechanical) “green” ‐ remaining element life “red” ‐ element needs replacing

Inlet/Outet Ports (1‐1/2 inch NPTF)

Head: Die Cast Aluminum

KMP9600 series (8 inch length)

Bowl Removal Nut:

Bowl O‐Ring (Viton®)

Bowl: Anodized Die Cast Aluminum

Gripped Surface for Hand Removal

Data tables and graphs may have interpolation and/or rounding variances.

Specifications are subject to change and/or be revised without notice.

Internal By‐Pass Valve (set at 44 psid)

Advanced Filtration Company 25-A Arnold Blvd. - P.O. Box 324 - Howell, N.J. 07731-0324

Phone: (732) 901-6676 Fax: (732) 901-6677 Web: www.advancedfiltration.com

E-mail: sales@advancedfiltration.com

File details come from the government source that posted it. Updated .