SATPC0039720 Tab 04 3 SOW..pdf

PDF 213 KB Posted

Attached to
3D imaging scanner system - Leica BLK360 G2 Starter Pack or Equivalent Federal contract opportunity
Solicitation number
80NSSC25914617Q
Issued by
National Aeronautics and Space Administration Shared Services Center

View the file

Other files for this federal contract opportunity

Other files attached to 3D imaging scanner system - Leica BLK360 G2 Starter Pack or Equivalent, newest first.
File Type Posted
SATPC0039720 Tab 10 RFQ Open Market Template.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

NASA Langley Research Center requires the purchase of one (1) 3D imaging scanner system, Leica BLK360 G2 (or Equivalent).

2. Characteristics, Scope, and Specs

The 3D imaging scanner system must meet the following technical requirements:

GENERAL:

• 3D imaging scanner with integrated high-speed HDR spherical imaging system

• IncludesVisual Inertial System (VIS) or equivalent for real-time pre-registration of scan positions

DESIGN & PHYSICAL CHARACTERISTICS

• Should be a compact, portable scanner designed for field use

• Would like it to be lightweight: < 2.2 kg

• Must have protection for transport

OPERATION

• Wireless LAN (802.11 b/g/n) connectivity

• Compatible with mobile apps (iOS and Android) for device control and data viewing

• Internal storage capacity for minimum of 1200 scan setups

• Operable in both upright and inverted positions

POWER

• Rechargeable battery

• Battery capacity must support > 70 full scan setups per charge

SCANNING CAPABILITIES

• High-speed time-of-flight measurement system

• Enhanced by waveform digitizing (WFD) or equivalent technology

• Laser Class: Safe for use under Class 1 laser designation (per IEC 60825-1:2014)

• Measurement range: 0.5 m to 45 m minimum

• Field of view: 360° horizontal, 270° vertical

• Point acquisition rate: > 600,000 points per second

• Should have user-selectable resolution settings

IMAGING SYSTEM

• May have an integrated multi-camera imaging system

• Captures spherical imagery at minimum 100 MP raw resolution

File details come from the government source that posted it. Updated .