This is a Sources Sought notice issued by the VA Network Contracting Office 22 in Long Beach, CA for cardiology equipment at the Northern Arizona VA Medical Center in Prescott, AZ. Responses are due February 28, 2025 at 4:00 PM PST to Hanan.Mccullick@va.gov.

The requirement is for supply, installation, configuration, and validation of a cardiac stress system product with ongoing technical support and maintenance services. The system must be equal to GE Cardiac Assessment System (CASE) V7.X with Windows 10 LTSC 2019 OS, Muse v9+ compatibility, DICOM capability, specific signal processing requirements, LCD display (>20"), and built-in EKG printer. A T2100-ST treadmill or equivalent is also required with 0-25% incline, 0.1-15 mph speed range, and specified safety features. The NAICS code is 339112 with responses requested from small businesses, particularly SDVOSBs/VOSBs. Respondents must provide detailed capability statements with reference contracts demonstrating relevant experience. This market research will determine if the procurement should be set aside for small businesses.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Cardiology Equipment

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
90815
SOLICITATION NUMBER*
36C26225Q0516
RESPONSE DATE/TIME/ZONE
02-28-2025 16:00 PACIFIC TIME, LOS ANGELES, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815

POINT OF CONTACT*

Contract Specialist Hanan McCullick Hanan.Mccullick@va.gov

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

Northern Arizona VA HCS

500 HW 89N

Prescott AZ

POSTAL CODE
86313

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

THIS REQUEST FOR INFORMATION (RFI) – SOURCES SOUGHT IS ISSUED SOLELY FOR MARKET RESEARCH AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION

1. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research only to make appropriate acquisition decisions and to gain knowledge of Small Businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses (SDVOSB/VOSB), who are interested in submitting proposals for this procurement and who are capable of performing the work required for this procurement.

2. The NAICS for this requirement is 339112 – Surgical and Medical Instrument Manufacturing

3. The Contractor shall supply, install, configure, and validate a cardiac stress system product and provide on-going technical support and maintenance services for that installed product for the Northern Arizona VA Medical Center located in Prescott, Arizona. The required services (installation, configuration, validation, support, and maintenance for cardiac stress system) shall be provided by the contractor along with all resources necessary to accomplish the deliverables described in the attached DRAFT Salient Characteristics.

4. Interested and capable Contractors are encouraged to respond to this notice not later than Friday, February 28, 2025 at 04:00 PM PST, by providing the following information via email only to Hanan.Mccullick@va.gov.

(a) Company name

(b) Address

(c) Point of contact

(d) Phone, fax, and email of primary point of contact

(e) Contractor’s Unique Entity ID (SAM) number

(f) Type of small business, if applicable, (e.g. Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), 8(a), HUB-Zone, Woman Owned Small Business, Small Disadvantaged Business, or Small Business).

(g) Statement indicating whether your company is considered small under the size standard for the NAICS code identified under this RFI.

(h) Statement indicating the product name of the cardiac stress system product referenced above that you intend to provide for this procurement.

(i) Statement indicating whether you are the manufacturer of the cardiac stress system product that you intend to provide for this procurement. If you intend to provide a cardiac stress system product manufactured by a company other than your own, state the name of the company whose cardiac stress system product you intend to provide, the country of origin for the product you intend to provide, and whether the company that manufactures that product is a small business under the size standard for the NAICS code identified under this RFI.

(j) Statement indicating if you have a current contract to provide the cardiac stress system product that you intend to provide for this procurement, along with the installation, configuration, validation, support, and maintenance services required by this procurement, under either the General Services Administration’s Federal Supply Schedule or with NAC, NASA SEWP, or any other federal contract. If yes, provide the contract type and contract number, as well as the identity of the federal agency with whom you hold that contract.

(k) Statement indicating how many calendar days you estimate it would take you to install, configure, and validate the cardiac stress system product that you intend to provide for this procurement in a medical center similar to the Northern Arizona VA Medical Center.

(l) General pricing for your products/solutions for market research purposes.

(m) A capability statement that provides detailed information for one or more reference contracts that demonstrate your experience providing cardiac stress system that meets the requirements described in the attached DRAFT Statement of Work and demonstrates your experience providing the installation, configuration, validation, support, and maintenance services required by this procurement. GENERAL STATEMENTS OF CAPABILITY ARE NOT ACCEPTABLE. Respondents must provide the following information for each reference contract the respondent identifies as evidence of the respondent’s capability to perform the work required by this procurement. Respondents must provide the following information for each reference contract:

(1) the legal name of entity with whom the respondent held the contract;

(2) the contract number;

(3) a description providing details of the specific tasks the respondent performed under that contract;

(4) the dates during which the respondent performed the contract;

(5) the name, phone number, and email address of a person at the entity with whom the respondent held the contract who can verify the information the respondent provides regarding this reference contract.

If a respondent offers to demonstrate experience through the proposed use of subcontractors, the respondent must identify the legal name of each subcontractor and provide all of the information required above for one or more reference contracts performed by each subcontractor the respondent intends to use.

NOTE: The information requested above is required for the Government to evaluate whether there are sufficient small business concerns of a particular type who are capable of performing the work required by this procurement to determine if this procurement should be set aside for a given type of small business concern. FAILURE TO SUBMIT ALL OF THE INFORMATION REQUESTED ABOVE MAY BE VIEWED BY THE GOVERNMENT AS EVIDENCE THAT THE RESPONDENT LACKS THE ABILITY TO PROVIDE THE CARDIAC STRESS SYSTEM AND SERVICES REQUIRED BY THIS PROCUREMENT. THIS, IN TURN, MAY AFFECT THE GOVERNMENT’S DETERMINATION ABOUT WHETHER THE REQUIREMENTS FOR A SET-ASIDE PROCUREMENT HAVE BEEN MET.

5. All Offerors who provide goods or services to the United States Government must be registered in the System for Award Management (SAM) database found at https://www.sam.gov. Registration must include Representations and Certifications.

--End of Sources Sought Announcement--

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SCHEDULE OF SUPPLIES:

SALIENT CHARACTERISTICS:

1. Brand name item or equal to GE Cardiac Assessment System (CASE) V7.X

a. Must have at a minimum Windows 10 LTSC 2019 Operating System.

b. Shall be compatible with Muse (Version 9 or later) Cardiac Information System.

i. System must have capability for MUSE Web retrieval view and printing of stored data.

c. Must be capable of exporting finalized reports in multiple formats.

d. Must have the ability to store reports locally.

e. Apparatus must be capable of having Bidirectional DICOM modality worklist/orders.

f. Signal Processing minimum requirements:

i. E, J and post-J signal processing technique – Manual or computer selected

ii. Baseline correction - ADS

iii. Artifact/Baseline correction – ADS or Finite Residual Filter

iv. Arrhythmia detection – Automatic arrhythmia detection, documentation, and annotation.

v. Reanalysis (Resting/Stress) – Re-analyze after manual correction of median beats and measurements. Post-test median measurements from E, J, post-J point selections.

vi. Full Disclosure EKG – Up to 60 minutes of full disclosure with event review both during and post-acquisition.

g. Display

i. Must be LCD (flat panel display)

ii. Resolution must be at a minimum 1680 x 1050.

iii. Display size must be greater than 20”.

iv. Display must have ability to tilt and rotate.

h. System must have built in EKG printer with paper tray to output results.

i. System must be capable of adjusting height.

j. Maximum physical dimensions (HxWxD): 68”x35x48”

k. Must have a minimum 1 year of warranty that starts after installation

2. Brand name or equal to T2100-ST Treadmill

a. Treadmill must be capable of incrementing incline from 0 to 25 percent.

b. Must provide speed range between 0.1 to 15 mph.

c. Safety features must include:

i. Dual comparative speed sensors

ii. Auto runaway shutdown

iii. Auto communication loss shutdown

iv. Manual twist lock Emergency Stop button

v. Manual stop tether

vi. Braking system for off-loading

d. Communication ports:

i. RS232 interface to Stress machine

ii. Minimum of 1 x USB port

e. Must have a minimum 1 year of warranty that starts after installation