This document is a Combined Synopsis/Solicitation Notice for a Request for Quotes (RFQ) issued by the Department of Veterans Affairs Veterans Integrated Service Network 22 for Belimed, Inc. Drying Cabinets or equivalent. The VA Long Beach Healthcare System is seeking a contractor to provide several Belimed, Inc. 350 and 150 Drying Cabinets that meet specific salient characteristics, including hospital grade stainless steel construction, integrated cooling and humidification, HEPA filtration, and specific temperature and humidity requirements. The solicitation is set aside for total small business and has a NAICS code of 339113 Surgical Appliance and Supplies Manufacturing with a size standard of 800 employees. Quotes are due by 12:00 PM PST on July 30, 2024 and should include vendor information, compliance with terms/conditions, a schedule of services with manufacturer part numbers, an authorized distributor letter if applicable, and compliance with the Buy American Act and Trade Agreement Act. The contract type is firm fixed price.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26224Q1586 0001.docx | DOCX document | |
| S02 36C26224Q1586.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice
| SUBJECT* |
| Drying Cabinets |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 90815 |
| SOLICITATION NUMBER* |
| 36C26224Q1586 |
| RESPONSE DATE/TIME/ZONE |
| 07-30-2024 12:00PM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SBA |
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
POINT OF CONTACT*
CONTRACTING SPECIALIST
ISRAEL GARCIA
ISRAEL.GARCIA2@VA.GOV
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
VA Long Beach Healthcare System
5901 East 7th Street
Long Beach CA
| POSTAL CODE |
| 90822-5201 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
1. This is a combined synopsis/solicitation for commercial services/items prepared in accordance with the format in FAR Subpart 12.6 in conjunction with FAR Part 13, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued.
1.a. Project Title: Drying Cabinets 1.b. Description: The VA Long Beach Healthcare System is seeking a contractor to provide several Belimed, Inc., Drying Cabinets.
1.c. Project Location: The VA Long Beach Healthcare System located in Long Beach, CA.
1.d. Solicitation Number: Request for Quotes (RFQ) - 36C26224Q1586.
1.e. Set Aside: Total Small Business Set-Aside 1.f. Applicable NAICS code: 339113 Surgical Appliance and Supplies Manufacturing 1.g. Small Business Size Standard: 800 employees 1.h. Type of Contract: Firm Fixed Price
2. Scope. The Veteran’s Integrated Service Network 22 is seeking a contractor to provide Belimed, Inc., 350 &150 Drying Cab Pkg. 120V Non-pass Thru or equivalent having the following salient characteristics, adhering to the S02 36C26224Q1586 attachment and provisions.
Brand name Information:
Manufacturer:
· Belimed, Inc Nomenclature:
1. 350 Drying Cab Pkg. 120V Non-pass Thru
2. 150 Drying Cab Pkg. 120V Non-pass Thru
3. Seismic Kit for 350/150 Drying cabinet
4. Installation/Equipment Assembly Installation Dryer Cabinet (INS-DC1) B-US-INS-DC1/WC1(350/150 Drying Cab)
5. Installation of seismic brackets B-US INS-SESMIC-MD (350/150 Drying Cab)
Model Number:
1. 1079211
2. 1079217
3. 1071558
4. 106-3240
5. 1052391
(Any other information):
Equal to product Information:
Salient Characteristics Custom Medical Racks 350 Drying Cab Pkg. 120V Non-Pass Thru Drying Cabinet Model 350 package, 120V single door non pass through. Package includes 350 model drying cabinet, 12 half width shelves, 2 drip pan, and a HEPA filtration system.
All the required Salient must be met as follows:
· Cabinets must meet specifically or be designed to meet VA Directive 1116(2) regarding the temperature of 66-72 F degrees and Humidity range 20%-60%. See attached VHA Directive 1116 (2).
· Vendor must provide manufactured hospital grade 304 stainless steel construction.
· Vendor must provide cabinets that have the integrated cooling and steam humidifier to maintain temperature and humidity conditions within the chamber.
· Vendor must provide Post-Sterile Storage Cabinets with an onboard custom control system that will utilize a digital display for monitoring temperature and humidity status.
· Vendor must provide mobile Post-Sterile Storage Cabinets with locking and unlocking foot mechanism on caster wheels because these must able to be relocated within hospital.
· Vendor must provide Post-Storage Cabinet with an integrated HEPA filtration system with 2-stage Prefilter and Boost Fan to meet the International Standards Organization which is recognized to prevent contamination and maintain cleanliness.
· Vendor must provide a 12 Perforated Stainless Steel Half-Width Shelves.
· Vendor must provide an integral condensate control system with 2 removable drip trays for collecting moisture.
· Vendor must provide an integral pressure monitoring with alarm either audible or visual to alert when out of range. Temperature must be between 66-72 degrees and Humidity between 20%-60%.
· Vendor must provide a see-through glass door.
· Vendor must provide VA approved steam humidification utilizing standard demineralized water, and an integral 2.8-liter reservoir filled through from spout access.
· Vendor must provide post-sterile storage cabinets with a 120V hospital grade minimum 10ft plug-in-cord.
· Must be 47.5 inches wide by 35.5inches deep and 90.5 inches high to fit into the existing space for designated use. If the cabinet is larger than these dimensions, it will not fit and it cannot be smaller because these have to be able to hold all the required medical sterile instrumentation.
· 350 Series - Model 350 or “Equal” is needed for this requirement.
· Assembly and Installation required.
· No training required.
150 Drying Cab Pkg. 120V Non-Pass Thru Drying Cabinet Model 150 package, 120V single door non pass through. Package includes 150 model drying cabinet, 6 half width shelves, 1 drip pan, and a HEPA filtration system.
All the required Salient must be met as follows:
· Cabinets must meet specifically or be designed to meet VA Directive 1116(2) regarding the temperature of 66-72 F degrees and Humidity range 20%-60%. See attached VHA Directive 1116 (2).
· Vendor must provide manufactured hospital grade 304 stainless steel construction.
· Vendor must provide cabinets that have the integrated cooling and steam humidifier to maintain temperature and humidity conditions within the chamber.
· Vendor must provide Post-Sterile Storage Cabinets with an onboard custom control system that will utilize a digital display for monitoring temperature and humidity status.
· Vendor must provide mobile Post-Sterile Storage Cabinets with locking and unlocking foot mechanism on caster wheels because these have to able to be relocated within hospital.
· Vendor must provide Post-Storage Cabinet with an integrated HEPA filtration system with 2-stage Prefilter and Boost Fan to meet the International Standards Organization which is recognized to prevent contamination and maintain cleanliness.
· Vendor must provide a 6 Perforated Stainless Steel Half-Width Shelves.
· Vendor must provide an integral condensate control system with 2 removable drip trays for collecting moisture.
· Vendor must provide an integral pressure monitoring with alarm either audible or visual to alert when out of range. Temperature must be between 66-72 degrees and Humidity between 20%-60%.
· Vendor must provide a see-through glass door.
· Vendor must provide VA approved steam humidification utilizing standard demineralized water, and an integral 2.8-liter reservoir filled through from spout access.
· Vendor must provide post-sterile storage cabinets with a 120V hospital grade minimum 10ft plug-in-cord.
· Must be 30.5 inches wide by 35.5inches deep and 90.5 inches high to fit into the existing space for designated use. If the cabinet is larger than these dimensions, it will not fit and it cannot be smaller because these have to be able to hold all the required medical sterile instrumentation.
· 150 Series - Model 150 or “Equal” is needed for this requirement.
· Assembly and Installation required.
· No training required.
3. Submit written offers with spec-sheets of proposed items in accordance with the following instructions, as well as Addendum to FAR 52.212-1, Instruction to Offerors. Oral offers will not be accepted. Complete and submit bid via email no later than 12:00PM PST Tuesday July 30, 2024, to israel.garcia2@va.gov. Ensure the following are completed and/or included in the quote packet:
3.a. Vendor Information with SAM UEI.
3.b. Concurrence/non-concurrence with solicitation terms, conditions, and provisions 3.c. Schedule of services. Items shall be FOB destination. Please specify offered item manufacturer and part number.
3.d. Provide an Authorized Distributor Letter/Memo from manufacturer if applicable.
3.e. Product must comply with the Buy American Act, Trade Agreement Act and all other clauses stated on the S02 36C26224Q1586 document.
PRICE/COST SCHEDULE
ITEM INFORMATION
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1.00 |
| EA |
| __________________ |
| __________________ |
150 Drying Cab Pkg. 120V Non-Pass Thru Drying Cabinet Model 150 package, 120V single door non pass through. Package includes 150 model drying cabinet, 6 half width shelves, 1 drip pan, and a HEPA filtration system.1079211
MANUFACTURER PART NUMBER (MPN): 1079211
LOCAL STOCK NUMBER: 1079211
| 1.00 |
| EA |
| __________________ |
| __________________ |
350 Drying Cab Pkg. 120V Non-pass Thru Drying Cabinet Model 350 package. 120V non pass through. Package includes 350 model drying cabinet, 12 half width shelves, 2 drip pans, and a HEPA filtration system 1079217
MANUFACTURER PART NUMBER (MPN): 1079217
LOCAL STOCK NUMBER: 1079217
| 2.00 |
| EA |
| __________________ |
| __________________ |
B-US-INS-DC1/WC1 Installation/Equipment Assembly Installation Dryer Cabinet (INS-DC1) 106-3240 (150/350 Drying Cab Pkg.)
MANUFACTURER PART NUMBER (MPN): 106-3240
LOCAL STOCK NUMBER: 106-3240
| 2.00 |
| EA |
| __________________ |
| __________________ |
B-US INS-SESMIC-MD 1052391 (150/350 Drying Cab Pkg.)
MANUFACTURER PART NUMBER (MPN): 1052391
LOCAL STOCK NUMBER: 1052391
| 2.00 |
| EA |
| __________________ |
| __________________ |
Seismic Kit for 350 and 150 Drying cabinet
MANUFACTURER PART NUMBER (MPN): 1071558
LOCAL STOCK NUMBER: 1071558
GRAND TOTAL
See attached document: S02 36C26224Q1586.
Page 1 of