6515--Drying Cabinets Federal contract opportunity
Solicitation number
36C26224Q1108
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22

About this file

This document is a Combined Synopsis/Solicitation Notice for a Request for Quotes (RFQ) for a Belimed, Inc. 350 Drying Cabinet or equivalent for the VA Long Beach Healthcare System.

The VA is seeking a contractor to provide a Belimed, Inc. 350 Drying Cabinet or equivalent that meets specific salient characteristics, including adhering to VA Directive 1116(2) for temperature and humidity ranges, hospital grade 304 stainless steel construction, integrated cooling and humidification, mobile cabinets with locking casters, HEPA filtration, and other requirements. The solicitation is a total Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, with an NAICS code of 339113 Surgical Appliance and Supplies Manufacturing. The response is due by 12:00PM PST on May 15, 2024. The contract type is Firm Fixed Price. Vendors must submit quotes and required documentation per the instructions, including compliance with the Buy American Act and Trade Agreement Act.

View the file

Other files for this federal contract opportunity

Other files attached to 6515--Drying Cabinets, newest first.
File Type Posted
S02 36C26224Q1108.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Combined Synopsis/Solicitation Notice

SUBJECT*
Drying Cabinets

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
90815
SOLICITATION NUMBER*
36C26224Q1108
RESPONSE DATE/TIME/ZONE
05-15-2024 12:00PM PACIFIC TIME, LOS ANGELES, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815

POINT OF CONTACT*

CONTRACT SPECIALIST

ISRAEL GARCIA

ISRAEL.GARCIA2@VA.GOV

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

VA Long Beach Healthcare System

5901 East 7th Street

Long Beach, CA

POSTAL CODE
90822-5201
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

*= Required Field
Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

1. This is a combined synopsis/solicitation for commercial services/items prepared in accordance with the format in FAR Subpart 12.6 in conjunction with FAR Part 13, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued.

1.a. Project Title: Drying Cabinet 1.b. Description: The VA Long Beach Healthcare System is seeking a contractor to provide a Belimed, Inc Drying Cabinet.

1.c. Project Location: The VA Long Beach Healthcare System located in Long Beach, CA.

1.d. Solicitation Number: Request for Quotes (RFQ) - 36C26224Q1108.

1.e. Set Aside: Total SDVOSB Set-Aside 1.f. Applicable NAICS code: 339113 Surgical Appliance and Supplies Manufacturing 1.g. Small Business Size Standard: 800 employees 1.h. Type of Contract: Firm Fixed Price

2. Scope. The Veteran’s Integrated Service Network 22 is seeking a contractor to provide a Belimed, Inc., 350 Drying Cab Pkg. 120V Non-pass Thru or equivalent having the following salient characteristics, adhering to the S02 36C26224Q1108 attachment and provisions.

Brand name Information:

Manufacturer:

· Belimed, Inc Nomenclature:

1. 350 Drying Cab Pkg. 120V Non-pass Thru

2. Seismic Kit for 150/350 Drying cabinet

3. Installation/Equipment Assembly Installation Dryer Cabinet (INS-DC1) B-US-INS-DC1/WC1

4. Installation of seismic brackets B-US INS-SESMIC-MD

Model Number:

1. 1079217

2. 1071558

3. 106-3240

4. 1052391

(Any other information):

Equal to product Information:

Salient Characteristics Custom Medical Racks 350 Drying Cab Pkg. 120V Non-Pass Thru Drying Cabinet Model 150 package, 120V single door non pass through. Package includes 350 model drying cabinet, 12 half width shelves, 2 drip pan, and a HEPA filtration system.

All the required Salient must be met as follows:

· Cabinets must meet specifically or be designed to meet VA Directive 1116(2) regarding the temperature of 66-72 F degrees and Humidity range 20%-60%. See attached VHA Directive 1116 (2).

· Vendor shall provide manufactured hospital grade 304 stainless steel construction.

· Vendor shall provide cabinets that have the integrated cooling and steam humidifier to maintain temperature and humidity conditions within the chamber.

· Vendor shall provide Post-Sterile Storage Cabinets with an onboard custom control system that will utilize a digital display for monitoring temperature and humidity status.

· Vendor shall provide mobile Post-Sterile Storage Cabinets with locking and unlocking foot mechanism on caster wheels because these have to able to be relocated within hospital.

· Vendor shall provide Post-Storage Cabinet with an integrated HEPA filtration system with 2-stage Prefilter and Boost Fan to meet the International Standards Organization which is recognized to prevent contamination and maintain cleanliness.

· Vendor shall provide a 12 Perforated Stainless Steel Half-width Shelves

· Vendor shall provide an integral condensate control system with 2 removable drip traysfor collecting moisture.

· Vendor shall provide an integral pressure monitoring with alarm either audible or visual to alert when out of range. Temperature must be between 66-72 degrees and Humidity between 20%-60%.

· Vendor shall provide a see-through glass door.

· Vendor shall provide VA approved steam humidification utilizing standard demineralized water, and an integral 2.8-liter reservoir filled through from spout access.

· Vendor shall provide post-sterile storage cabinets with a 120V hospital grade minimum 10ft plug-in-cord.

· Must be 47.5 inches wide by 35.5inches deep and 90.5 inches high to fit into the existing space for designated use. If the cabinet is larger than these dimensions, it will not fit and it cannot be smaller because these have to be able to hold all the required medical sterile instrumentation.

· 50 Series - Model 350 or “Equal” is needed for this requirement.

· Assembly and Installation required.

· No training required.

3. Submit written offers with spec-sheets of proposed items in accordance with the following instructions, as well as Addendum to FAR 52.212-1, Instruction to Offerors. Oral offers will not be accepted. Complete and submit bid via email no later than 12:00PM PST Wednesday May 15, 2024, to israel.garcia2@va.gov. Ensure the following are completed and/or included in the quote packet:

3.a. Vendor Information with SAM UEI.

3.b. Concurrence/non-concurrence with solicitation terms, conditions, and provisions 3.c. Schedule of services. Items shall be FOB destination. Please specify offered item manufacturer and part number.

3.d. Provide an Authorized Distributor Letter/Memo from manufacturer if applicable.

3.e. Product must comply with the Buy American Act, Trade Agreement Act and all other clauses stated on the S02 36C26224Q1108 document.

3.f. Fill out and sign the VA NOTICE OF LIMITATIONS ON SUBCONTRACTING--CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS located within the S02 36C26224Q1108 document with your submission.

PRICE/COST SCHEDULE

ITEM INFORMATION

ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1.00
EA
__________________
__________________

350 Drying Cab Pkg. 120V Non-pass Thru Drying Cabinet Model 350 package. 120V non pass through. Package includes 350 model drying cabinet, 12 half width shelves, 2 drip pans, and a HEPA filtration system

PN: 1079217

LOCAL STOCK NUMBER: 1079217

1.00
EA
__________________
__________________

Seismic Kit for 150/350 Drying cabinet

PN: 1071558

LOCAL STOCK NUMBER: 1071558

1.00
EA
__________________
__________________

Installation/Equipment Assembly Installation Dryer Cabinet (INS-DC1)/B-US-INS-DC1/WC1 PN: 106-3240

LOCAL STOCK NUMBER: 106-3240

1.00
EA
__________________
__________________

Seismic Kit installation B-US INS-SESMIC-MD

PN: 1052391

LOCAL STOCK NUMBER: 1052391

GRAND TOTAL
__________________

See attached document: S02 36C26224Q1108.