KUPFERLE

Since 1857

2511 NORTH 9TH STREET

ST. LOUIS, MO 63102

1-800-231-3990

FAX 314-231-2820

www.hydrants.com

#9766HC-MB AUTOMATIC FLUSHING STATION SPEC SHEET

Automatic Flushing Station (AFS) shall be installed in the following location(s): _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Automatic flushing station shall be wall mounted, having 2 independent valve assemblies, with each enclosed in a separate lockable, non-removable 6" aluminum box with hinged openings.

The left assembly, designed for hot water, shall use a 1" S.S. waterway, with a 1" FIP union inlet, that will lead vertically through a S.S. maintenance ball valve to the bottom of a 1" automatic flushing valve and have a water temperature rating of 150°F. The right assembly, designed for standard temperature water, shall use a 1" Sch. 80 PVC waterway, with a 1" FIP union inlet, that will lead vertically through a S.S. maintenance ball valve to the bottom of a 1" automatic flushing valve and have a water temperature rating of 140°F.

Each flushing valve shall control the flow of the water through the hydrant and its diaphragm with the extension and retraction of a DC latching solenoid. Both valves shall have a 150 PSI rating. All flushed water shall be plumbed away per the installation design specifications.

Each valve system shall be furnished with a stand alone valve controller. The valve controller will not require a second hand-held device for programming. Controller must have a minimum of 12 possible flushing cycles per day. Controller shall be submersible up to 12 feet, operate with two 9 volt batteries, and have resin sealed electrical components. The solenoid shall have no loose parts when removed from the valve.

When open, the station shall require no key for operation. Also, when open, the station shall utilize a chain attached to the front door and inside wall of the enclosure to create a flip-down table.

Each valve assembly shall have a dedicated sampling point on the hydrant located before the 1" flushing valve.

Unit model # shall be #9766HC-MB as specified in the product ordering guide as manufactured by Kupferle Foundry Company, St. Louis MO, or approved equal.

Scale: 1-1/2"=1'

#9766-HC-MB STANDARD TOP VIEW

Scale: 1-1/2"=1'

#9766-HC-MB STANDARD FRONT VIEW

PATENTED

Scale: 1-1/2"=1'

#9766HC-MB ISOMETRIC VIEW

A

Scale: 3"=1'

OPTIONAL 1" BRASS DUAL CHECK VALVE

B

0 10 20 30 40 50 60 70

Fl ow

R at e (G

PM

Differential Pressure

1" ICV Valve

.5 Turns 1 Turn 1.5 Turns 2 Turns 2.5 Turns 3 Turns 3.5 Turns

AutoCAD SHX Text

NOTE A

AutoCAD SHX Text

DATE

AutoCAD SHX Text

STATUS / REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

MODIFIED

AutoCAD SHX Text

INITIALS

AutoCAD SHX Text

OF

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

SHEET SIZE

AutoCAD SHX Text

ITEM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

AutoCAD SHX Text

LOCKABLE TOP ACCESS LID

AutoCAD SHX Text

AutoCAD SHX Text

LOCKABLE FRONT ACCESS DOOR

AutoCAD SHX Text

AutoCAD SHX Text

SHELF CHAIN

AutoCAD SHX Text

AutoCAD SHX Text

DC LATCHING SOLENOID

AutoCAD SHX Text

AutoCAD SHX Text

1/4" COPPER TUBING SAMPLING POINT

AutoCAD SHX Text

AutoCAD SHX Text

PADLOCK EYE

AutoCAD SHX Text

AutoCAD SHX Text

PADLOCK HASP

AutoCAD SHX Text

AutoCAD SHX Text

WALL MOUNT BRACKET

AutoCAD SHX Text

AutoCAD SHX Text

1" AUTOMATIC FLUSHING VALVE

AutoCAD SHX Text

AutoCAD SHX Text

1" S.S. BALL VALVE

AutoCAD SHX Text

AutoCAD SHX Text

VALVE CONTROLLER

AutoCAD SHX Text

AutoCAD SHX Text

1" FIP S.S. PIPE UNION

AutoCAD SHX Text

AutoCAD SHX Text

1" S.S. WATERWAY

AutoCAD SHX Text

AutoCAD SHX Text

1" SCH. 80 PVC WATERWAY

AutoCAD SHX Text

AutoCAD SHX Text

1" FIP SCH. 80 PVC UNION

AutoCAD SHX Text

AutoCAD SHX Text

6" ALUMINUM BOX

AutoCAD SHX Text

AutoCAD SHX Text

1" DUAL CHECK VALVE

AutoCAD SHX Text

OPTIONAL

AutoCAD SHX Text Automatic Product Ordering Guide

AutoCAD SHX Text

MODEL#

AutoCAD SHX Text

9766HC

AutoCAD SHX Text

AutoCAD SHX Text

MB

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text X

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

SUBSECTION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MODEL SHOWN IS: 9766HC-MB-0-A-X-X

AutoCAD SHX Text

SUBSECTION DESCRIPTION

AutoCAD SHX Text

MODEL # SUBSECTION

AutoCAD SHX Text

OPTIONS

AutoCAD SHX Text

DESCRIPTIONS

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

AutoCAD SHX Text

9766HC

AutoCAD SHX Text

AUTOMATIC FLUSHING DEVICE (DUAL WATER SUPPLY - HOT & COLD)

AutoCAD SHX Text

CLIMATE

AutoCAD SHX Text

AutoCAD SHX Text

MB

AutoCAD SHX Text

INDOORS ABOVE 41°F (5°C)

AutoCAD SHX Text

DEPTH OF BURY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N/A

AutoCAD SHX Text

SAMPLING OPTIONS

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

1/4" COPPER GOOSENECK

AutoCAD SHX Text B

AutoCAD SHX Text

STAINLESS STEEL PETCOCK

AutoCAD SHX Text

HOT/COLD IDENTIFICATION

AutoCAD SHX Text

AutoCAD SHX Text X

AutoCAD SHX Text

STICKERS

AutoCAD SHX Text A

AutoCAD SHX Text

POWDER COATED (RED & BLUE) DOORS AND LIDS

AutoCAD SHX Text

BACKFLOW OPTIONS

AutoCAD SHX Text

AutoCAD SHX Text X

AutoCAD SHX Text

NONE

AutoCAD SHX Text A

AutoCAD SHX Text

1" DUAL CHECK VALVE

AutoCAD SHX Text

#9766HC-MB SPEC SHEET

AutoCAD SHX Text

VARIES

AutoCAD SHX Text B (11x17)

AutoCAD SHX Text

NOTES

AutoCAD SHX Text A

AutoCAD SHX Text

IF SPECIFIED, DUAL CHECK TO BE LOCATED BEFORE OUTLET UNION

AutoCAD SHX Text B

AutoCAD SHX Text

INLET AND OUTLET PIPE LENGTHS MAY VARY SLIGHTLY

AutoCAD SHX Text

DCL

AutoCAD SHX Text 1/16/18

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

JRG

AutoCAD SHX Text 1/16/18

AutoCAD SHX Text

GENERAL HYDRANT SPECIFICATIONS

AutoCAD SHX Text

MAXIMUM OPERATING PRESSURE:

AutoCAD SHX Text

150 PSI

AutoCAD SHX Text

MAXIMUM STANDARD WATER TEMPERATURE:

AutoCAD SHX Text 140°F (60°C)

AutoCAD SHX Text

MAXIMUM HOT WATER TEMPERATURE:

AutoCAD SHX Text 150°F (65.5°C)

AutoCAD SHX Text

HYDRANT MATERIALS:

AutoCAD SHX Text

303, 316, AND 18-8 STAINLESS STEEL, SCH. 80 PVC, BRASS, COPPER

AutoCAD SHX Text

ENCLOSURE MATERIAL:

AutoCAD SHX Text

ALUMINUM

AutoCAD SHX Text

ENCLOSURE COLOR:

AutoCAD SHX Text

HOT: DOOR & LID - RED

AutoCAD SHX Text

COLD: DOOR & LID - BLUE

AutoCAD SHX Text

WETTED MATERIALS:

AutoCAD SHX Text

SCH. 80 PVC, TEFLON, EPDM, 316 S.S., BRASS

AutoCAD SHX Text

DEPTH OF BURY:

AutoCAD SHX Text N/A

AutoCAD SHX Text

WEIGHT:

AutoCAD SHX Text

~30 LBS

AutoCAD SHX Text

NOTE A

AutoCAD SHX Text

NOTE A

Sheets and Views
#9766HC-MB - Landscape