36C25918R0561-002.pdf
PDF 1 MB Posted
- Attached to
- B6 Renovation Project No. 575-17-05S Federal contract opportunity
- Solicitation number
- 36C25918R0561
About this file
36C25918R0561 All Drawings.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25918R0561-0003001.pdf | ||
| 36C25918R0561-0003000.docx | DOCX document | |
| 36C25918R0561-0002001.pdf | ||
| 36C25918R0561-0002000.docx | DOCX document | |
| 36C25918R0561-0001000.docx | DOCX document | |
| 36C25918R0561-0001004.pdf | ||
| 36C25918R0561-0001003.pdf | ||
| 36C25918R0561-0001001.pdf | ||
| 36C25918R0561-0001002.pdf | ||
| 36C25918R0561-001.docx | DOCX document | |
| 36C25918R0561-003.pdf | ||
| 36C25918R0561-000.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
North Avenue gas
GRAND JUNCTION VA
RESIDENCY GRANT 575-18-05S
2121 North Avenue Grand Junction, CO Site Plan MAY 2018
Property Line
B
A
P:A
P:A
P:B
P:B
AREA OF CONSTRUCTION
DRAWING LIST
DWG. 1 SITE PLAN
DWG. 2 DEMOLITION
DWG. 3 ARCHITECTURAL
DWG. 4 MECHANICAL
DWG. 5 ELECTRICAL DEMOLITION
DWG. 6 ELECTRICAL
DWG. 7 FLOOR JACKS/POWER DATA
DWG. 8 REFLECTED CEILING
DWG. 9 EXISTING DATA SYSTEMS
DWG. 10 SPECIAL SYSTEMS
DWG. 11 UNDERGROUND DATA DUCT
DWG. 12 ALTERNATES
LAC
102A
103A
CORRIDOR
CORRIDOR
STAIRS
107230SF
RESIDENCY GRANT
575-17-05S
DEMOLITION PAGE 2 of 12
NTS JHB 5-1-18
6L
6L1
6L2
ELECTRIC
SD
DEMOLITION NOTES
A DEMO ACOUSTIC CEILING.
B DEMO WALL, FRAMES DOORS.
C DEMO EVAP SUPPLY GRILL. CAP & FILL
CONCRETE STRUCTURE.
D RELOCATE STROBE/SPEAKER:FA & MCOM.
E RELOCATE PULL STATION.
F DEMO FLOORING.
G REMOVE WOOD WINDOW SILL.
H REMOVE MEDIA BOARD. RETURN TO VA.
I RELOCATE DATA/POWER
J EXIT LIGHT TO REMAIN
K MINI-SPLIT AC UNITS TO REMAIN
L REMOVE EXISTING WINDOW.
M REMOVE LAV, CAP WASTE IN CRAWLSPACE.
RECONNECT VENTS AS REQUIRED IN CEILING
SPACE.
N RELOCATE CIRCUITS AS REQUIRED.
O FIRE SPRINKLERS TO REMAIN.
P REMOVE EXHAUST FAN AND DUCT. SEAL
OPENING. DEMO SWITCH & CIRCUIT.
Q REMOVE LIGHT TROFFERS. UTILIZE SINGLE
SINGLE CIRCUIT FOR NEW LED FIXTURES.
R REMOVE CORRIDOR WALL FIXTURES.
S VERIFY EGRESS LIGHTING CIRCUIT.
T RELOCATE ALL CENTRAC DEVICES.
U RELOCATE THERMOSTATS.
V REMOVE ANCHOR
W REMOVE TRANSITE BOARD
O
A
A
B
B
C
E
D
F
F
G
A
H
I
24' verify v e r i f y
J
K
K
K
IT
CLOSET
IT CLOSET
L
L
F
G
G
G
G G
S
O
O
ATTIC
ACCESS
41' typ.
10"
P
SR
Q
D
T
T
T
T
UU
U
W W
W
W
W
W
DEMOLISH
CORRIDOR
STAIRS
RESIDENCY GRANT
575-17-05S
ARCHITECTURAL PAGE 3 of 12
NTS JHB 5-1-18
ARCHITECTURAL NOTES
A NEW ACOUSTIC CEILING.
B NEW WALL, FRAME AND DOOR. 3-6x7-0 S.C.
CLASSROOM LOCKSET, HOLD OPEN CLOSURE.
C PANIC HARDWARE SET.
D SOLID SURFACE WINDOW SILL.
E PATCH AND PAINT AS ALL INTERIOR AS REQUIRED.
F ELECTRIC OPERATED PROJECTOR SCREEN.
FLUSH MOUNT DA-LITE DESIGNER
CONTOUR OR APPROVED EQUAL.
G NEW FLOORING. SEE DRWG 12 OF 12.
H NEW BLACK OUT BLINDS. SEE DRWG 12 OF 12.
I HIGH DENSITY SOUND BLANKETS.
J MAGNETIC DRY ERASE BOARD. FIT CORNER TO
CORNER. 4'0" WIDE X 6'0" HIGH.
K EXTEND ALL WALLS TO STRUCTURE ABOVE.
D
A
F
B
F
K
A
C
E
G
106A IT106A IT
D
D
D
D
DD
F
F
E
E
E
E
E
E
G
G
G
H
H
H
H
HH
IT
CLOSET
ELEV.
A
EXISTING
WALL
NEW
WALL
I
J
J
J
J J
J
J J J
J
J
J
J J
J
K
K
K
47" 67"
67" 47"
Susp. Ceiling
Steel Box Rail See Detail
48" typ.6"
Rail Supports
Susp. Ceiling
Rail Support
ELEVATION good
NTS
Flat Panel
Flat Panel Section
NTS JHB 5-4-18
See Section
Susp. Ceiling
See Section
EAST WALL ELEVATION
Sound Attenuation and Marker Assemblies
NTS JHB 5-4-18
Magnetic dry erase
Susp. Ceiling Grid
Susp. Ceiling Tile
Painted Acoustic Tile
Metal "L"
Marker Sheet
Sound Tile Section
NTS JHB 5-4-18
CORRIDOR
CORRIDOR
STAIRS
RESIDENCY GRANT
575-17-05S
MECHANICAL PAGE 4 of 12
NTS JHB 5-1-18
MECHANICAL NOTES
A REMOVE AND RETAIN -4- FUJITSU AUU36RCLX
UNITS. SEE DRWG. 7 OF 9.
B REMOVE AND RETAIN THERMOSTATS/CONTROL
MODULES-MINISPLIT (2).
C REMOVE AND RELOCATE PNEUMATIC
THERMOSTAT.
D NEW MINI-SPLIT THERMOSTAT LOCATION.
E PROVIDE SINGLE PNEUMATIC THERMOSTAT
FOR -6- EXISTING STEAM RADIATORS.
6L
6L1
6L2
ELECTRIC
106A IT
B
IT
CLOSET
A
A
A
A
C
C
E
EXISTING RADIATOR
W/ PNEU. VALVE-TYP. -6-
B B
B
D D
D D
CORRIDOR
STAIRS
RESIDENCY GRANT
575-17-05S
ELECTRICAL DEMOLITION PAGE 5 of 12
NTS JHB 5-1-18
6L
6L1
6L2
ELECTRIC
SD
ELECTRICAL DEMOLITION NOTES
A DISABLE CIRCUIT/MINI-SPLIT. RETAIN.
B REMOVE LIGHT FIXTURE, SWITCH & CIRCUIT.
C REMOVE ALL 2x4 LIGHT FIXTURES. RETAIN
CIRCUITS.
D REMOVE EXISTING WALL FIXTURES. RETAIN
EGRESS CIRCUIT.
E REMOVE AND REINSTALL EXIT.
F REMOVE AND REINSTALL FA AND MC.
G REMOVE AND REINSTALL ALL CENTRAC.
SEE DWG. 2.
DEMOLITION
A
H
E
IT
CLOSET
IT CLOSET
S
ATTIC
ACCESS
D
C
G
G
U
A
A
A
A
S
S
B
B
C
MC
F
F
F
F
F
6L-1-36
6L-1-41
G
6L-1-31
6L-1-41
6L-1-33
6L-23
B
6L-1-33
STAIRS
RESIDENCY GRANT
575-17-05S
ELECTRICAL PAGE 6 of 12
NTS JHB 5-1-18
SP
ELECTRICAL NOTES
A RECONNECT LINE VOLTAGE.
B PROVIDE CONDUIT/J-BOX @ 48" FOR FLAT PANEL
CONTROLS.
NOTE: COORDINATE ALL FLOOR PENETRATIONS.
SEE SECTION A, DRAWING NO. 7.
6L
6L1
6L2
ELECTRIC
106A IT
109 IT
A
A
A
A
JB
JB
6L
1 LITES OFFICES 2 RECPT 11
3 LITES 114 4 EWC
5 LITES 115,16A,16B 6 HC-1 MOTOR
7 RECPT OFFICE 8 HC-1 MOTOR
9 LITES 115 10 HC-2 MOTOR
11 LITES 114,15 12 HC-2 MOTOR
13 LITES 117-19,21-22 14 HC-3 MOTOR
15 LITES 101,02,02A,EXT 16 HC-3 MOTOR
17 LITES 104-106,09,13 18 HC-4 MOTOR
19 LITES 106A,08,08A,
10,11,11A, 20 HC-4 MOTOR
21 LITES 100 22 EC-1
23 LITES 106,13 24 EC-1
25 LITES BASMENT 26 CP-1
27 RECPT 101,02 28 CP-1
29 RECPT 100 30 CP-1
31 RECPT 102A 32 RECPT 116
33 RECPT 103,03A 34 RECPT 115E
35 RECPT 112,12A 36 RECPT 113
37 REC 105,06,07,10,11 38 RECPT 118
39 REPCT 108, 08A 40 RECPT 119,19A
41 RECPT 104,04A 42 RECPT 120A,21,21A
6L1
43 SPARE 30A 44 RECPT
45 SPARE 30A 46 LITES
47 RECEPT BMT 48 AIR COMP
49 RECPT OFFICE 50 RECPT
51 BLANK 52 EMCSMAT
53 6BP1 60A 54 DISC HEAT MAT
55 6BP1 60A 56 SPARE 30A
57 6BP1 60A 58 MAIN 60A
59 6BP1 60A 60 MAIN 60A
61 BLANK 62 MAIN 60A
63 BLANK 64 BLANK
65 BLANK 66 BLANK
67 BLANK 68 BLANK
69 BLANK 70 BLANK
71 BLANK 72 BLANK
73 FMS 74 CONNFERENCE RM CASSETTES
75 ANK 76 CONFERENCE RM CASSETTES
77N. CONDENSER 78 N. SMALL CONDENSER
79. CONDENSER 80 N. SMALL CONDENSER
81S. CONDENSER 82 S. SMALL CONDENSER
83S.CONDENSER 84 S. SMALL CONDENSER
6L2
1 FLR JCK 103 2 FLR JCK 103
3 FLR JCK 103 4 FLR JCK 103
5 BLANK 6 BLANK
7 BLANK 8 BLANK
9 BLANK 10 BLANK
11 BLANK 12 BLANK
13 BLANK 14 BLANK
15 BLANK 16 BLANK
17 BLANK 18 BLANK
19 SPARE 20A 20 BLANK
21 SPARE 20A 22 BLANK
23 SPARE 20A 24 BLANK
25 SPARE 20A 26 SPARE 20A
27 SPARE 20A 28 SPARE 20A
29 SPARE 20A 30 SPARE 20A
31 SPARE 60A 32 CONF.RM CASSETTES
33 SPARE 60A 34 CONF.RM CASSETTES
35 N. CONDENSER 36 N. SML CONDENSER
37 N. CONDENSER 38 N. SML CONDENSER
39 S. CONDENSER 40 S. SML CONDENSER
41 S. CONDENSER 42 S. SML CONDENSER
6L-2-5 @ 8'-6"
JB
JB
STAIRS
SP
A
IT CLOSET
106A-6
A
IT CLOSET
109-6
6L
6L1
6L2
ELECTRIC
ELECTRICAL NOTES
A Combination power (2) and data (2) floor jack.
Locate within apex of joist/pan concrete structure.
See detail.
RESIDENCY GRANT
575-17-05S
FLOOR JACKS-DATA/POWER PAGE 7 of 12
NTS JHB 5-1-18
106A IT
A
26"
SECTION A-JOIST/PAN
NTS
AREA OF PENETRATION
SECT A
CONCRETE PAN LAYOUT
FASTEN TO UNI-STRUT
6L-2-1
6L-2-2
6L-2-3
6L-2-4
CORRIDOR
STAIRS
RESIDENCY GRANT
575-17-05S
REFELCTED CEILING PAGE 8 of 12
NTS JHB 5-1-18
REFLECTED CEILING NOTES
A NEW ACOUSTIC CEILING.
B LED LIGHT 2x4 TROFFER/CONTROLS:
2FSL4 EZ1 LP835 N100 OR APP EQUAL
NWSX PDT LV DX-SWITCH/DIMMER.
C CONNECT TO EXISTING EGRESS CIRCUIT.
6L
6L1
6L2
ELECTRIC
106A IT
Sb
EXISTING
JB
Sa
Sa Sa
Sa
Sa Sa
Sb
Sb
Sb
A
B
TYP.
6L-23
6L-27
RESIDENCY GRANT
575-17-05S
EXISTING DATA SYSTEMS PAGE 9 of 12
NTS JHB 5-1-18
SD
FA
SP
SPECIAL SYSTEMS NOTES
A RELOCATE EXISTING FIRE ALARM COMPONENTS.
B RELOCATE MASS COMM.
C 2-CAT6e CABLE FROM SERVICE POINT ROOM
106A. TERMINATE.
D RELOCATE ALL SIGNAL CABLING AND EQUIPMENT
FROM 109-6 TO 106A. REMOVE ABANDONED
CABLING. TERMINATE AND CERTIFY FUNCTION.
E JOHNSON CONTROL ACCESS SYSTEM-NIC
F QUEST WIFI (PINK CAT6e)-NIC
G FIBER OPTIC JUNCTION BOX-NIC
6L
6L1
6L2
ELECTRIC
A
A
106A IT
B
MC
6-1-36B
6-1-36A
6-1-36V
6-1-37B
6-1-37A
6-1-37V
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-2B
6-1-2A
6-1-2V
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6-1-?
6L-1-36
SP
ANALOG
REMOVE
E F
G GD
RESIDENCY GRANT
575-17-05S
SPECIAL SYSTEMS PAGE 10 of 12
NTS JHB 5-1-18
SD
FA
SP
SPECIAL SYSTEMS NOTES
NOTE: DUPLEX DATA JACK-RJ45 W/ CAT6e
A RELOCATE EXISTING FIRE ALARM COMPONENTS.
B RELOCATE MASS COMM.
C 2-CAT6e CABLE FROM SERVICE POINT ROOM
106A. TERMINATE WITH RJ-45.
D RELOCATE ALL SIGNAL CABLING AND EQUIPMENT
FROM 109-6 TO 106A. REMOVE ABANDONDED
CABLING. TERMINATE AND CERTIFY FUNCTION.
E PROVIDE 24 STRAND, MULTIMODE FIBER OPTIC
FROM 106A-6 TO BUILDING 34 VIA SERVICE HOLE 5.
F PROVIDE APC AR203A OR APPROVED EQUAL.
G PROVIDE TWO (2) LEVITON 5R2UL-F06 OR
APPROVED EQUAL.
6L
6L1
6L2
A
A
106A IT
P
B
MC
6-1-46A
6-1-46B
6-1-43A
6-1-43B
6-1-44A
6-1-44B
6-1-45A
6-1-45B
6-1-47A
6-1-47B
6-1-48A
6-1-48B
6-1-52A
6-1-52B
6-1-53A
6-1-53B
6-1-54A
6-1-54B
6-1-57A
6-1-57B
6-1-59A
6-1-59B
6-1-61A
6-1-61B
6-1-58A
6-1-58B
6-1-63A
6-1-63B
6-1-62A
6-1-62B
POINT OF TERMINATION, ALL
CAT6e/CAT5e CABLING
DEMARCATION LINE:
SWING NEW
CABLE CABLE
6-1-49A
6-1-49B
6-1-50A
6-1-50B
6-1-51A
6-1-51B
6-1-68A
6-1-68B
6-1-56A
6-1-56B
6-1-60A
6-1-60B
6-1-64A
6-1-64B
6-1-65A
6-1-65B
6-1-66A
6-1-66B
6-1-67A
6-1-67B
6-1-55A
6-1-55B
IT
IT
E
NOTE:
FIBER OPTIC CABLE: 106A-6
TO B34 VIA SERVICE HOLE 5:
140 L.F. VERIFY
3" PVC CONDUIT TO COM
SERVICE HOLE
6-1-69A
6-1-69B
6-1-70A
6-1-70B
CREDIT UNION
CARPORT
SMOKE
SHACK5
PARKING
GARAGE
CARPORT
S
Sewer
S
Sewer
Drain
Chilled Water
S
S
B
D C
J
H
P N
O
M
Signal
MH3A
Signal Gunnison Ave.
Signal
MH1
Signal
MH2
Signal
MH2A
Signal
MH5
Signal
MH3
Signal
MH2B
Signal
MH3A
Signal
MH2C
Signal
MH2D
A
E
F
G
I
K
L
Q R
S T
TEMP B
TEMP A
U V
W
X
Y Z
BB
JB
RESIDENCY GRANT
575-17-05S
UNDERGROUND COMMUNICATION DUCT
NTS JHB 5-1-18
CONFERENCE ROOM
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text
ONLY
CONFERENCE ROOM
LOBBY
ED/STORAGE
VESTIBULE
114A131 SF
720 SF
268SF
RESTROOM
KITCHEN
CORRIDOR
HOUSEKEEPING
CLOSET
111A
STAIRS
230 SF
RESTROOM
RESIDENCY GRANT
575-17-05S
BASE/ALTERNATES PAGE 12 of 12
NTS JHB 5-11-18
ELECTRIC
CARPET NOTES NOTES
A BASE BID-ROOM 103, 100, 102, 106, 108,
110, 112, 113, 114, 115, 117, 118, 119, 120, 121, 122
MOHAWK KT253 OR
APPROVED EQUAL. VERIFY AREAS.
B ALTERNATE BID: ROOM 103.
MOHAWK KT253 OR
APPROVED EQUAL. VERIFY AREAS.
C COVE BASE: ROPPE, 6" CONTINUOUS,
"FAWN", 140.
SHAREWALL NOTES
A BASE BID-ROOM 103, ALL WALLS
SHAREWALL: FLOOR TO 6' A.F.F. OR
APPROVED EQUAL.
B ALTERNATE BID:
SHAREWALL: ON WALLS MARKED AS "N",
"E" AND "S".
NIC
IT CLOSET
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
IT CLOSET
NIC
AB
B
B
B
B
B
B
B B
B
B
B
B
B
129 SF
121 SF124 SF
145 SF
94 SF
280 SF
1095 SF
456 SF
119 121
118 122
293 SF
N
E
E
S
CORRIDOR
| RG 1 OF 12 |
| Sheets and Views |
| Model |
| RG 2 0F 12 |
| Sheets and Views |
| Model |
| RG 3 OF 12 |
| Sheets and Views |
| Model |
| RG 4 OF 12 |
| Sheets and Views |
| Model |
| RG 5 OF 12 |
| Sheets and Views |
| Model |
| RG 6 OF 12 |
| Sheets and Views |
| Model |
| RG 7 OF 12 |
| Sheets and Views |
| Model |
| RG 8 OF 12 |
| Sheets and Views |
| Model |
| RG 9 0F 12 |
| Sheets and Views |
| Model |
| RG 10 OF 12 |
| Sheets and Views |
| Model |
| RG 11 OF 12 |
| Sheets and Views |
| Model |
| RG 12 OF 12 |
| Sheets and Views |
| Model |
File details come from the government source that posted it.