36C25818Q9786-000.docx
DOCX document 16 KB Posted
- Attached to
- Surgical Power Tools- Stryker Brand Name only Federal contract opportunity
- Solicitation number
- 36C25818Q9786
About this file
36C25818Q9786 36C25818Q9786_1.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| -14974.docx | DOCX document | |
| 36C25818Q9786-004.docx | DOCX document | |
| 36C25818Q9786-002.docx | DOCX document | |
| 36C25818Q9786-005.pdf | ||
| 36C25818Q9786-003.docx | DOCX document | |
| 36C25818Q9786-001.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Combined Synopsis/Solicitation Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Combined Synopsis/Solicitation Notice Rev. March 2010 Surgical Power Tools- Stryker Brand Name only 87108 36C25818Q9786 08-27-2018 N 339112 Department of Veterans Affairs NCO22-Gilbert Network Contracting New Mexico VA Health Care System 1501 San Pedro Drive SE Albuquerque NM 87108 Bryan.Rogers2@va.gov ship all items to:
New Mexico VA Health Care System 1501 San Pedro Dr SE, bldg 46 Albuquerque, NM 87108-5128 Bryan.Rogers2@va.gov bryan.rogers2@va.gov See attached document: NOTICE for combined synopsis-solicitation.
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. The solicitation number is 36C25818Q9786 and is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect: for FAR 52.212-5: FAC2005-97 effective 1/24/18, and for Commercial Items, FAC 2005-99 effective 7/15/18. The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 with a small business size standard of 1000 employees. This solicitation is for Stryker brand name only equipment, justification attached. FOB destination, deliver all products to: New Mexico VA Health Care System, 1501 San Pedro Dr SE, Bldg 46, Albuquerque, NM 87108-5128.
REQUIREMENTS:
Contract Title. Raymond G. Murphy VA Medical Center (Albuquerque, NM) Request three surgical power instruments sets (Stryker System 7) & replacement parts for systems on hand for the Sterile Processing Service.
Background. The procurement of three surgical power instruments sets (Stryker System 7) for the Sterile Processing Service is necessary to address surgical requirements in Podiatry and Orthopedic surgical services.
Scope. The overall scope of work is the procurement of three surgical power instruments sets (Stryker System 7). Instrument sets consist of Power Hand Pieces, attachments, and instrument baskets, and replacement parts for unrepairable attachments and hand pieces. The selected equipment manufacturer will furnish all necessary equipment. These instrument sets will be provided for the Raymond G. Murphy VA Medical Center.
Surgical Power Hand pieces must have:
Drill/Ream switch; eliminates switching between drilling and reaming attachments Provide up to 157in/lbs of torque Compatibility with Facility owned Stryker System 7 instruments, batteries and attachments
* Hand pieces validated for automated washing and sterilization Bar codes on hand pieces Integrated Remote Device Management
Instrument insert baskets for Surgical Power Hand pieces must have:
Insert trays allow hand pieces and attachments to be loaded into one sterilization case All tray inserts fit both rigid and wrapped sterilization containers
| Item # |
| Description |
| Delivery |
| Qty |
| U/I |
| 0001 |
| System 7 V-Notch Sagittal Saw product 7208008000 |
| 30 DARO |
| 3 |
| EA |
| 0002 |
| System 7 Reciprocating Saw product 7206000000 |
| 30 DARO |
| 3 |
| EA |
| 0003 |
| System 7 Dual Trigger Rotary Handpiece product 7205000000 |
| 30 DARO |
| 5 |
| EA |
| 0004 |
| AO Small Attachment product 6203110000 |
| 30 DARO |
| 4 |
| EA |
| 0005 |
| AO Large Reamer Attachment product 6203210000 |
| 30 DARO |
| 5 |
| EA |
| 0006 |
| Hudson/Modified Trinkle Attachment product 6203135000 |
| 30 DARO |
| 5 |
| EA |
| 0007 |
| 1/4” Keyed Chuck product 6203131000 |
| 30 DARO |
| 4 |
| EA |
| 0008 |
| Pin collet (2.0 – 3.2mm) product 7203126000 |
| 30 DARO |
| 6 |
| EA |
TRAINING and INSTALLATION:
No training or installation of equipment is required.
SELECTION CRITERIA:
Price.
End, Statement of Requirements
Interested vendors are directed to solicitation 36C25818Q9786.
Providing price quotes for ALL line items as listed above is required.
***Question Submission:
Interested offerors shall submit all questions concerning the RFQ at the earliest possible time to enable the Buyer to respond. Questions shall be submitted via email to: Bryan.Rogers2@va.gov. NO phone calls will be accepted. Amendments to the RFQ addressing inquiries or concerns will be posted as an amendment to the RFQ on this same website. Questions not received within a reasonable time prior to close of the RFQ may not be considered. ***
New Stryker products only; NO remanufactured or "gray market" items. All items shall be covered by manufacturer's warranty.
Quote shall be valid for a minimum of 60 calendar days after due date of quotations.
This solicitation requires registration by the vendor with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov.
Prior to any award, a vendor/contractor must be ‘vendorized’. Forms required for vendorization are included in solicitation 36C25818Q9786.
Failure to comply with the terms and conditions as stated in this announcement may result in offer being determined as non-responsive.
The selected Offeror shall comply with all clauses and provisions as listed in the RFQ. The full text version of any referenced federal acquisition regulation (FAR) or Veterans Affairs clauses and provisions may be accessed electronically at: http://farsite.hill.af.mil.
Additional Info:
Contracting Office Address:
Department of Veterans Affairs 1501 San Pedro Dr SE Albuquerque, NM 87108-5128 Point of Contact:
Bryan S. Rogers, Contract Specialist, Bryan.Rogers2@va.gov
File details come from the government source that posted it.