36C25718Q0133-004.pdf
PDF 384 KB Posted
- Attached to
- AMA B48 PC Furniture Federal contract opportunity
- Solicitation number
- 36C25718Q0133
About this file
36C25718Q0133 PC 2nd Fl AE102-1.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25718Q0133-00004001.docx | DOCX document | |
| 36C25718Q0133-00004000.docx | DOCX document | |
| 36C25718Q0133-00004002.zip | ZIP file | |
| 36C25718Q0133-00004003.zip | ZIP file | |
| 36C25718Q0133-00003001.docx | DOCX document | |
| 36C25718Q0133-00003000.docx | DOCX document | |
| 36C25718Q0133-00002000.docx | DOCX document | |
| 36C25718Q0133-00002001.docx | DOCX document | |
| 36C25718Q0133-00001001.docx | DOCX document | |
| 36C25718Q0133-00001000.docx | DOCX document | |
| 36C25718Q0133-00001002.xlsx | XLSX spreadsheet | |
| 36C25718Q0133-002.pdf | ||
| 36C25718Q0133-000.docx | DOCX document | |
| 36C25718Q0133-003.pdf | ||
| 36C25718Q0133-005.pdf | ||
| 36C25718Q0133-001.docx | DOCX document |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8
A
C
E
F
G
H
J
RISER
MED GAS
WALK-IN
EXAM
TOILET
BLOOD DRAW
PROCEDURE
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
SHARED
CONSULT
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
SHARED
CONSULT
SHARED
CONSULT
SHARED
CONSULT
CORRIDOR
CONSULT
RECEPTION
AIRLOCK
MEN
WOMEN
PATIENT
EDUCATION
CONFERENCE
VEND
WAITING
C O
R R
I D
O R
C O
R R
I D
O R
C O
R R
I D
O R
C O
R R
I D
O R
HAC
ALCOVE
FAMILY
ALCOVE
BREAK
LOCKERS
ELEC
MED
SOILED BIOMED TELECOMM
STAFF
STAFFSTAFF
STAFF
C O
R R
I D
O R
CLEAN
35'-5 1/2" 70'-8 1/2" 30'-0 1/2" 18'-1 1/2"
5'-8" 12'-6"
4'-10"
8'-8"
4'-10" 12'-6" 5'-8" 12'-6" 4'-10" 8'-8"
4'-10"
12'-6"
5'-8"
12'-6" 4'-10" 8'-8" 4'-10" 12'-5 1/2" 5'-8 3/4"
9'-7 1/2" 8'-9 1/4"
6"
3'-4" 15'-9" 12'-1" 9'-1" 12'-1" 15'-9" 12'-1" 6'-1"
12'-1"
19'-6 1/2" 10'-10 3/4" 6'-1"
5'-8"5'-8" 5'-8"
8'-4 7/8" 5'-3 3/4" 17'-0 1/8" 7'-10 1/8" 6'-6 3/8" 7'-10 1/8" 8'-4" 10'-0" 8'-4"
7'-3 1/4"
8'-5 1/8" 8'-11 5/8" 5'-10"
3'-4" 9'-2" 18'-4" 9'-2" 3'-4" 3'-4" 9'-2" 18'-4" 9'-2" 3'-4" 3'-4" 9'-2" 18'-4" 9'-2" 9'-0"
9'-2" 3'-4"
4'-0 1/4"
WHEELCHAIR
ALCOVE
5'-10" 10'-6 1/4" 11'-2 3/4" 8'-2" 8'-5 3/4"
CONSULT
COMMONS
154'-4"
STAIR #1
E Q
E Q
EQ EQ
4'-8 1/4" 8'-11 1/4" 4'-8 3/4"
23'-0" 24'-5 3/4"
3'-9"
7'-6"
1'-4 1/2"
LOBBY
LOBBY
5'-8"
5'-7 1/2" 7'-4" 6'-2" 9'-6"
1'-5"
17'-9 1/2" 3 3/4"
4'-6 3/4"
3'-10 3/8"
1'-2"
7'-2"
3'-10 1/2"
2'-8" 9'-8 3/4" 7'-3 3/8"1'-11"
6'-6 3/4"
2'-3 3/4"
8'-11"
5 1/2"
5'-4 1/2"
18'-8" 16'-9 1/2"
18'-2 1/2" 19'-0" 30'-0" 19'-0" 30'-0" 19'-0" 18'-4 1/4"
D
8'-11"
8'-11"
18'-9 3/4"
11'-2 3/4"
16'-3 3/4" 19'-1 3/4"
5 1/2"
15'-10 1/4"
2'-4 1/4"
7'-1 3/4"
4'-10 1/2"
2'-5 1/2"
10 1/2" 6 1/2"
6'-7 1/4" 11'-6" 11'-6" 11'-6" 11'-6" 11'-6" 6'-7 1/4"
2'-2 1/2"
4'-4 3/4"
2'-7 1/4"
8'-10 3/4" 10'-1 1/4"
1'-4 3/4"
4'-5"
5'-4"
1'-8"
6'-7 1/4"
3'-10"
4'-11 1/4" 2'-4 3/4"
9'-6" 5'-0"
1'-0"
1'-0"
4"
4"
4"
4"
4"
4"
8'-5" 9'-6 1/2"
5'-5 1/4" 3'-7 1/2"
5'-6 1/4"
3 3/4"
4'-0 1/2"
4'-0 1/2"
8'-0"
MIN.
B
TEAM HUDDLE
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
o n e e i g h t h i n c o e f o t t h r e e i n c h e s o t o n e a d a l f i n c h e s o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t
VA FORM 08-6231
E
D
C
B
A
BES DESIGN/BUILD, LLC
766 Middle St, Fairhope, AL 36532
Phone: 251.990.5778
Fax: 251.990.3716 of
23456
123456
F
E
D
C
B
A
DESIGN/BUILD
5/15/2015 10:36:38 AM
BID DOCUMENTS
PRIMARY CARE ADDITION
PHASE 1
LEVEL 2 - DIMENSION PLAN
THOMAS CREEK VA MEDICAL CENTER
AMARILLO, TEXAS
504-222
AE102.1
2015.05.15 JDB RWC
AMARILLO VA
HEALTH CARE
SYSTEM
13734
1/8" = 1'-0"
LEVEL 2 - DIMENSION PLAN
PARTITION / BARRIER LEGEND
GENERAL FLOOR PLAN NOTES
A DEPICTION OF EXISTING CONDITIONS BASED ON
OWNER-FURNISHED DOCUMENTS AND LIMITED FIELD
OBSERVATIONS. EXISTING ELEMENTS AND CONDITIONS
CONCEALED BY IN-PLACE EQUIPMENT AND FINISHES WERE NOT
OBSERVED OR INVESTIGATED. ONCE CUTTING AND SELECTIVE
DEMOLITION WORK IS COMPLETE, REPORT ANY CONFLICTS TO
DESIGNER. THE CONTRACTOR SHALL MAKE ADJUSTMENTS
AND/OR ALTERATIONS AS NECESSARY TO INSTALL COMPLETE
AND OPERABLE SYSTEMS IN ACCORDANCE WITH THE CODES
HAVING JURISDICTION AT NO ADDITIONAL COST TO THE
GOVERNMENT.
B REFER TO SHEET GI004 FOR ABBREVIATIONS AND QH SERIES
SHEETS FOR EQUIPMENT PROCUREMENT AND INSTALLATION
RESPONSIBILITY DESIGNATIONS.
C UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISHED
FACE OF PARTITIONS (EXCLUDING APPLIED FINISHES SUCH AS
TILE) AND TO COLUMN CENTER LINES.
D CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO
ANCHOR ALL WALL AND CLG MOUNTED ITEMS, INCLUDING BUT
NOT LIMITED TO TOILET ROOM ACCESSORIES, MILLWORK,
CASEWORK, HANDRAILS, DOOR STOPS ETC.
E IN NEW GYPSUM WALL BOARD PARTITIONS, PROVIDE CONTROL
JOINTS AT 30'-0" O.C. MAX.
F REFER TO SHEET GI003 FOR PARTITION TYPES AND GENERAL
PARTITION TYPE NOTES.
G REFER TO QH SERIES SHEETS FOR EQUIPMENT LOCATIONS AND
SCHEDULE.
H TYPICAL PARTITION TYPE TO BE (B_4A) UON. (SEE 'PARTITION
TYPE' SYMBOL LEGEND ON SHEET GI003)
I REFER TO FIRE PROTECTION LIFE SAFETY DRAWINGS FOR
SCOPE OF RATED WALL CONSTRUCTION, SMOKE PARTITIONS,
EGRESS AND EXIT DISCHARGE INFORMATION.
J PARTITION TYPES AS NOTED BY THE SYMBOL CONTINUE
BETWEEN ROOM/SPACE CORNERS OR ANY INTERSECTING
PARTITION.
K DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL
PLANES CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR
SPACES.
L REFER TO AE600 SERIES DRAWINGS FOR DOOR, FRAME &
WINDOW TYPES AND DOOR SCHEDULE.
M DISTANCE FROM HINGE SIDE OF DOOR TO INTERSECTING STUD
WALL SHALL BE 4” UNLESS NOTED OR DETAILED OTHERWISE
(MEASURED FROM OUTSIDE OF FRAME)
N CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS
“CLEAR” OR “MIN". DIMENSIONS NOTED AS “HOLD” ARE CRITICAL
TO COORDINATE OTHER WORK (E.G. CEILING GRIDS, LIGHTING,
FINISHES).
O CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO
INITIATING CONSTRUCTION AND REPORT DISCREPANCIES TO
ARCHITECT PRIOR TO COMMENCING WORK.
P ALL PENETRATIONS THROUGH RATED FLOOR/CEILING
ASSEMBLIES AND THROUGH FIRE RATED WALL AND SMOKE
BARRIER ASSEMBLIES MUST BE SEALED AS PART OF THIS
CONTRACT WITH APPROPRIATE FIRE RATED MATERIAL. ALL
RATED SEPARATIONS MUST MEET CURRENT CODE
REQUIREMENTS.
Q REFER TO QH400 SERIES SHEETS FOR IDENTIFICATION AND
LOCATION OF WALL PROTECTION. ALL WALL PROTECTION TO
BE SUPPLIED AND INSTALLED BY CONTRACTOR.
R REFER TO SHEET AE601 FOR WINDOW SHADE TYPES AND
DESCRIPTION.
S ALL EXTERIOR WALL DIMENSIONS SHOWN ARE TO FACE OF
CMU/CONC., ALL INTERIOR PARTITIONS ARE DIMENSIONED TO
THE FACE OF GYPSUM BOARD.
LEVEL 1: 3673.5'
LEVEL 2: 3691.5'
N
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it.