36C25620Q0184-002.pdf

PDF Posted

Attached to
Power poles and data install. Federal contract opportunity
Solicitation number
36C25620Q0184
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

About this file

36C25620Q0184 S02 Attachment 2 2016-12-22 VAMC BILOXI - BLDG 2 - Final - Telecom Drawings.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Power poles and data install., newest first.
File Type Posted
36C25620Q0184-0002003.docx DOCX document
36C25620Q0184-006.docx DOCX document
36C25620Q0184-000.docx DOCX document
36C25620Q0184-003.pdf PDF
36C25620Q0184-001.pdf PDF
36C25620Q0184-004.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T ectonic Cop yright 2007

J

J J

J

J

J

JJ

J

J

J

J

J

J

J

J

J

J

J

J

JJ

J

J

TVTV

J

C

C R

M D

L

PB

CR

M D

L PB

C

C

CR

MDL

PB

CR

MDL

PB

C

C R

MDL

PB

CR

MS

C

PB

CR

M D

L

J

J J

J

J

J

JJ

J

JJ

J

J

TV

TV

J

J

TV

C

PB

CR

M D

L

VESTIBULE

1A100

CORRIDOR A

C1-1

LOBBY

1B100

STORAGE/FILE

1B102A

HAC

1B101 HR SPEC (SUPV)

1B102B

CONSULT

1B103

CONSULT

1B104

CONSULT

1B106

HR - ER/LR

1B102

HR - PROCESSING

& RECORDS

1B105

CONSULT

1B107

STORAGE/FILE

1B108A

WF DEV SUPR

1B108C

HR - WORK FORCE

DEVELOPMENT

1B108

ASST HR OFCR

1B109A

HR OFCR

1B109B

HR - OFFICE OF

CHIEF

1B109

BREAK ROOM

1B111

CORRIDOR E

C1-7

STORAGE/FILE

1B113

UNASSIGNED

OFFICE

1B112

HR - PIV

1B114

SUPR HR

SPECIALIST

1B115ACONSULT

1B116

CONSULT

1B117

CONSULT

1B118

MECH

1B119

HR - RECRUITMENT

& PLACEMENT

1B115

MEN

1B120

WOMEN

1B121

CORRIDOR F

C1-6

EXIST MECH

1B123

EXIST MECH

1B122

CORRIDOR D

C1-5

CENTRAL STAIR

S1-1

EXIST ELEC

1A123ELEC GEAR

1A122C

EXIST ELEC

1A122

ELEC

1A122BSECURITY

1A122A

COMM

1A120

FAMILY

RESTROOM

1A121MEN

1A119

WOMEN

1A118

CORRIDOR G

C1-4

SOILED UTILITY

1A113

MECH

1A112

CONSULT

1A111

INFO SECURITY

OFFICER

1A110A

PRIVACY/

COMPLIANCE/ ISO

1A110

COMPLIANCE

OFFICER

1A110D

EAST STAIR

S1-2

PRIVACY/FOIA

1A110C

STORAGE/FILE

1A110B

CORRIDOR C

C1-3

BREAK ROOM

1A109

MANAGER

1A107A

FILE/COPY

1A107B

EEO OFFICE

1A107

STORAGE

1A107C

WAITING

1A106

EQUIPMENT

STORAGE

1A105

CONFERENCE

1A104

ICE MACHINE

1A101E

MEDICINE

1A101D

IMD SUPPLY

1A101C

CONFERENCE

1A103

CONSULT

1A102

HBPC OFFICE

1A101

OFFICE

1A101B OFFICE

1A101A

EXIST EAST

VESTIBULE

1A108

EXIST WEST

VESTIBULE

1B110

EXIST

ELEVATOR 1

EXIST

ELEVATOR 2

WEST STAIR

S1-3

STORAGE

1A104A

SUPPLY

1A117

ENGINEERING

STORAGE

1A116

SUPERVISOR EMS

1A115AEMS WORKROOM

1A115

EMS EQUIPMENT

1A114

1.1 2 3 4 5 6 70 13.11312111098 15

B

C

D

E

F

G

A.2

H

11.210.410.29.39.28.16.15.25.14.54.13.1

A.1

OFFICE

1A110E

72"

42"

4D/4V

4D/4V

4D/4V 4D/4V 4D/4V

4D/4V

4D/4V4D/4V

4D/4V

4D/4V

4D/4V

4D/4V 4D/4V

4D/4V

4D/4V

2D/2V

4D/4V

2D/2V

2D/2V

4D/4V

4D/4V6D/6V

4D/4V

6D/6V

TV

54"

12"x4"

12"x4" 12"x4"

12"x4"

12"x4" 12"x4"

12"x4"

12"x4"

12"x4"

12"x4"

4D/4V

NETWORK

SWITCH

PERSONNEL

DURESS SYS.

DOOR ACCESS

CNTRL PNL

9' AFF

TN151

TN151

10' AFF

18"x4" 18"x4"

WAP

4D/4V

4D/4V 4D/4V

4D/4V

2D/2V

4D/4V

4D/4V2D/2V

2D/2V

2D/2V4D/4V

4D/4V

4D/4V

72"

72" 72"

4D/4V

4D/4V

42"

4"ø

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP WAPWAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

42"

72"E352 2

E3522

114 SF

COMM

1A120

6S

6S

12"x4"

12"x4"

12"x4"

12"x4"

12"x4"

9'AFF

9'AFF

9'AFF

10'AFF

10'AFF

10'AFF

DOWN

6S

114 SF

COMM

1A120

RACKRACK

DOWN

2 2

4"ø

TMGB

Architect Project No.

DESIGN BUILD TEAM: CONSULTANTS:

Drawing Title:Project Title:

Location:

DateCheckedDrawn

Drawing Number

Building Number

Project Number

Revisions:DateDwg.of

Office of Construction and

Facilities Management VAMC BILOXI, MISSISSIPPI

89 7 6 5 4 3 2 1

F

E

D

C

B

A

89 7 6 5 4 3 2 1

VA FORM 08-6231, OCT 1978

o n e e ig h t in c h o n e fo o t o n e q u a rte r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rte rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

520.317U

QGM CWF NOVEMBER 21, 2016

1409 / 14-021

BUILDING 1 & 2 RENOVATIONS 1ST FLOOR - TELECOM

TN151

BUILDING 2

1/8" = 1'-0" TN151

11ST FLOOR - TELECOM

3/8" = 1'-0" TN151TN151

NEW PLAN FLOOR 1 - TELECOM ROOM - LARGE SCALE

CEILING PLAN 3/8" = 1'-0" TN151TN151

NEW PLAN FLOOR 1 - TELECOM ROOM - LARGE SCALE

PLAN

NO

RT

H

KEYED NOTES:

1. SEE TYPICAL LOBBY ELEVATION SHEET

AE151.

2. PROVIDE 3/4" PLYWOOD BACKBOARDS ON

ALL WALLS IN TELECOM ROOM, PAINT GRAY.

Todd Sanders

J J

J

J

J

J

J

J

J

J

J

J

J

J

CC

PB

CR

M D

L

TV

J

J

JJ

J

J J

TVTV

J

J J

J

J

J

J JJ

J J

J J

JJ

J J

J J

JJ

J J

J J

J

JJJJJ

J J

J

J J

J J

J

J

TV

C

PB

CR

M D

L

C

CORRIDOR A

C2-1

FISCAL OFFICE

2B100

HAC

2B101 MCA SUPR

2B100A

CONSULT

2B102

SUPR PAYROLL

2B100B

FISCAL OFFICE

2B103

WORKROOM

2B100C FIN MNGR

2B103A

CHIEF FIN MNGR

2B103B

CHIEF ACCNT

2B100F

COPY

2B100E

WORKROOM

2B100D

FISCAL OFFICE

2B104

UNASSIGNED

2B105

BREAK ROOM

2B106

CORRIDOR E

C2-5FILE STORAGE

2B107

FILE/STORAGE

2B108

FACILITY CIO

2B109A

FILES

2B109B

IT WORKROOM

2B109D

OFFICE

2B109C

OI&T/INFORMATION

MANAGEMENT

2B109

UNASSIGNED

2B110

MECH

2B111

MEN

2B113

WOMEN

2B114

CONFERENCE

2B112VENDING

2A115C

UNASSIGNED

OFFICE

2A115B

LOBBY

2A115

CORRIDOR D

C2-4

UNASSIGNED

OFFICE

2A115A

CORRIDOR G

C2-7

CONFERENCE

2A112

ELEC

2A114

SECURITY

2A111

COMM

2A110

FAMILY

RESTROOM

2A113

MEN

2A109

WOMEN

2A108

NVCC OFFICE

2A105

UNASSIGNED

OFFICE

2A107

MECH

2A106

LEAD PSA DOD

BILLING

2A105B

PRGM MGR

2A105A

BREAK ROOM

2A104

CORRIDOR C

C2-3

103 SF

STORAGE/FILE

2A103C

NVCC OFFICE

2A103

104 SF

STORAGE/FILE

2A100B

CLNCL MGR

2A103B

CHIEF/NVCC

2A103A NVCC OFFICE

2A100

EQUIP/MAIL

2A100A

UNASSIGNED

OFFICE

2A102

CONSULT

2A101

EXIST

ELEVATOR 1

EXIST

ELEVATOR 2

CORRIDOR B

C2-2

CORRIDOR F

C2-6

WEST STAIR

S2-3

CENTRAL STAIR

S2-1

EAST STAIR

S2-2

1.1 2 3 4 5 6 70 13.11312111098 15

B

C

D

E

F

G

A.2

H

11.210.410.29.39.28.16.15.25.14.54.13.1

A.1 60"

72"

CL

2D/2V

2D/2V

2D/2V 2D/2V

8D/8V

8D/8V

6D/6V

4D/4V

4D/4V

4D/4V

4D/4V

4D/4V

4D/4V

4D/4V

12"x4"

12"x4"

12"x4"

12"x4"

12"x4"

12"x4"

18"x4"18"x4"18"x4"18"x4"

10' AFF

9' AFF

12"x4"

12"x4"

WAP

TN152

TN152

2D/2V

4D/4V

4D/4V

2D/2V

4D/4V4D/4V

4D/4V

4D/4V

4D/4V

72"

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V2D/2V

2D/2V

2D/2V

2D/2V2D/2V

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V2D/2V

2D/2V 2D/2V

2D/2V2D/2V2D/2V 2D/2V

2D/2V2D/2V

2D/2V 2D/2V

2D/2V 2D/2V 2D/2V 2D/2V

2D/2V 2D/2V2D/2V2D/2V

2D/2V

2D/2V 2D/2V 2D/2V 2D/2V 2D/2V

4"ø

WAP

WAP

WAP WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP WAP

WAP

72"

E352

60" 60" E3522

COMM

2A110

TMGB

1 1

4"ø

149 SF

COMM

2A110

142 SF

MEN

2A109

18"x4"

18"x4"

12"x4"

12"x4"

18"x4"

12"x4"

9' AFF

9'4" AFF

9' AFF

10' AFF

10' AFF9' AFF

DOWN

10' AFF

6S 6S

6S6S

RACK RACK

Architect Project No.

DESIGN BUILD TEAM: CONSULTANTS:

Drawing Title:Project Title:

Location:

DateCheckedDrawn

Drawing Number

Building Number

Project Number

Revisions:DateDwg.of

Office of Construction and

Facilities Management VAMC BILOXI, MISSISSIPPI

89 7 6 5 4 3 2 1

F

E

D

C

B

A

89 7 6 5 4 3 2 1

VA FORM 08-6231, OCT 1978

o n e e ig h t in c h o n e fo o t o n e q u a rte r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rte rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

520.317U

QGM CWF NOVEMBER 21, 2016

1409 / 14-021

BUILDING 1 & 2 RENOVATIONS 2ND FLOOR - TELECOM

TN152

BUILDING 2

1/8" = 1'-0" TN152

12ND FLOOR - TELECOM

3/8" = 1'-0" TN152TN152

22ND FLOOR LARGE SCALE COMM ROOM - TELECOM

3/8" = 1'-0" TN152TN152

2ND FLOOR LARGE SCALE COMM ROOM CEILING PLAN -

TELECOM

NO

RT

H

KEYED NOTES:

1. PROVIDE 3/4" PLYWOOD BACKBOARDS

ON ALL WALLS IN TELECOM ROOM, PAINT

GRAY.

2. BOX, COVER AND RACEWAY TO

ACCESSIBLE CEILING ONLY.

UP

J

J

J

J J

J

J

J

J

J

J

J

JJ

J

JJ

J

J

C

C

PB

CR

M D

L

JJJ J

JJJJ J

J

J

J

J

J J

TV TV

TV

TV

TV

TV S

TV

S

TV

TV

S

S S

S

J

J

J

J

J

J

J

J J

J

J J

JJ

JJ

J

J J J J

J

J

J

J

J

J

J

M M

C

C

TV

S

C

TV

M

C

TV

TV

TV

TV

TV

CC

PB

CR

M D

L

J

J

S

S S

S

J

J

J

J

J

TV

TV

CORRIDOR A

C3-1

LOBBY

3B100

STORAGE

3B102A

AUDITORIUM

3B102

VIRTUAL OFFICE

3B103

SIM LAB CONTROL

3B105

STORAGE

3B105A

SIM LAB RR

3B106A

SIM LAB RR

3B104A

CORRIDOR H

C3-8

ACUTE SIM LAB

3B104

ICU SIM LAB

3B106

CONFERENCE

3B108

CORRIDOR F

C3-6

BREAK ROOM

3B109

CORRIDOR E

C3-5

UNASSIGNED

OFFICE

3B111

LACTATION

3B110

WEST STAIR

S3-3

VIRTUAL OFFICE

3B112

CHIEF,

CONSTRUCTION,

PLT

3B113A

CONSULT

3B114CHIEF, SERVICES,

PLT

3B113B

CONSULT

3B115

MECH

3B116

NOC-16 OFFICE

3B113

MEN

3B118

WOMEN

3B119

CAC OFFICE

3B117

CAC SUPVR

3B117A

VENDING

3A114A

LOBBY

3A114

CORRIDOR D

C3-4

CORRIDOR G

C3-7

FILE

3A107A

OFFICE

3A107B

OAA & CLC

SUPPORT

3A107

ELEC

3A113

SECURITY

3A112

FAMILY

RESTROOM

3A111

COMM

3A110MEN

3A109

WOMEN

3A108

UNASSIGNED

OFFICE

3A106

MECH

3A105

COMPUTER LAB

3A104

MAS OFFICE

3A103

COPY/FILE

3A103B

SUPR SCANNER

3A103A

CORRIDOR C

C3-3

BREAK ROOM

3A102

EAST STAIR

S3-2

NURSING

ADMINISTRATION

OFFICE

3A100

HAC

3B101

ADMIN OFCR

3A100B

FILE

3A100C

FILE/COPY

3A101A

ADMIN OFCR

3A101B

CHIEF, BUSINESS

3A101C

SUPR CODING

3A101D

CHIEF, AMB &

WARD

3A101E

CHIEF, HIMS

3A101F

EQUIP STOR

3A101G

MAS OFFICE

3A101

CHIEF, MAS

3A101I

ASST CHIEF, MAS

3A101H

CORRIDOR B

C3-2

CENTRAL STAIR

S3-1

EXIST

ELEVATOR 1

EXIST

ELEVATOR 2

CHIEF NURSE

3A100A

STORAGE

3B107

1.1 2 3 4 5 6 70 13.11312111098 15

B

C

D

E

F

G

A.2

H

11.210.410.29.39.28.16.15.25.14.54.13.1

A.1

42"

CL

72"

12"x4"

12"x4"

12"x4"

12"x4"

12"x4"

18"x4"

12"x4"

12"x4"

12"x4"

12"x4"

12"x4"

N L

11 2

EL154

18"x4"18"x4"

10' AFF

9' AFF

WAP

TN153

TN153

4D/4V 4D/4V

4D/4V4D/4V 2D/2V

4D/4V 4D/4V

4D/4V4D/4V 2D/2V

2D/2V

4D/4V 4D/4V4D/4V2D/2V

6D/6V

6D/6V

2D/2V

6D/6V

4D/4V

6D/6V

6D/6V

6D/6V 6D/6V

4D/4V

4D/4V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

4D/4V

4D/4V

4D/4V

2D/2V

NRk

Ns Na

N2J

NP

Nsr

72" N Rk

NsNa

N 2J

NP

N sr

72"

ON

HEADWALL

ON

HEADWALL

6D/6V

6D/6V

6D/6V

6D/6V

6D/6V

72"

S

S

S

S

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V 2D/2V

2D/2V

2D/2V 2D/2V 2D/2V 2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

2D/2V

42"

42"

80" 80"

42"

42"

80"

CEILING

MOUNTED

E352

E352

E352 1

4"ø

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

80"

E352

12"x4"

9' 7"

TO

BOTTOM

9' 4"

TO

BOTTOM

9' 4"

TO

BOTTOM

42"42"

E352

280" 80"

TN153

COMM

3A110

18"x4"

12"x4"

12"x4"

12"x4"

9' AFF

9'4" AFF

10' AFF

10' AFF

DOWN

10' AFF

RACKRACK

9' AFF

9' AFF

COMM

3A110

TMGB

RACK RACK7 7

4"ø

UNASSIGNED

OFFICE

3A106

MECH

3A105

COMPUTER LAB

3A104

3 4

B

C

D

A.2

3.1

A.1

Architect Project No.

DESIGN BUILD TEAM: CONSULTANTS:

Drawing Title:Project Title:

Location:

DateCheckedDrawn

Drawing Number

Building Number

Project Number

Revisions:DateDwg.of

Office of Construction and

Facilities Management VAMC BILOXI, MISSISSIPPI

89 7 6 5 4 3 2 1

F

E

D

C

B

A

89 7 6 5 4 3 2 1

VA FORM 08-6231, OCT 1978

o n e e ig h t in c h o n e fo o t o n e q u a rte r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rte rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

520.317U

QGM CWF NOVEMBER 21, 2016

1409 / 14-021

BUILDING 1 & 2 RENOVATIONS 3RD FLOOR - TELECOM

TN153

BUILDING 2

1/8" = 1'-0" TN153

13RD FLOOR - TELECOM

KEYED NOTES:

1. DATA FOR SIMULATOR SERVER/PC.

2. A/V SYSTEM IS ROUGH IN ONLY BY E.C.

EQUIPMENT SUPPLIED BY OTHERS.

3. INSTALL FOUR 1" CONDUITS AND CABLES,ONE

EACH FOR XLR,HDMI, VIDEO, AND CAT6.

COORDINATE LOCATIONS WITH A/V INSTALLER.

INSTALL ONE OPEN PULLBOX WITH CONDUIT AND

CABLING BACK TO A/V RACK, LOCATE ABOVE

CEILING.

4. INSTALL TWO 1" CONDUITS AND CABLING FOR

XLR A/V. COORDINATE LOCATIONS WITH A/V

INSTALLER.

5. A/V RACK WILL BE LOCATED HERE, ALL CABLING

FOR AUDITORIUM IS TO BE ROUTED BACK TO THIS

LOCATION.

6. A/V RACK WILL BE LOCATED HERE, ALL CABLING

FOR CLASSROOM IS TO BE ROUTED BACK TO THIS

LOCATION.

7. PROVIDE 3/4" PLYWOOD BACKBOARDS ON ALL

WALLS IN TELECOM ROOM, PAINT GRAY.

8. ACCESS HATCH THIS AREA FOR ATTIC ACCESS,

LEAVE AREA BELOW UNOBSTRUCTED.

3/8" = 1'-0" TN153TN153

3RD FLOOR LARGE SCALE COMM RM CEILING PLAN-

TELECOM

3/8" = 1'-0" TN153TN153

33RD FLOOR LARGE SCALE COMM ROOM - TELECOM

NO

RT

H

1/4" = 1'-0" TN153TN153

3RD FLOOR LARGE SCALE COMPUTER ROOM -

TELECOM