Text version
FedBizOpps Sources Sought Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Sources Sought Notice Rev. March 2010
STERRAD 100NX STERILIZER
66048 36C25519Q0445 05-13-2019 N 339112 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth KS 66048 Denise Maynard, denise.maynard@va.gov Robert J. Dole VA Medical Center 5500 E. Kellogg Avenue Wichita, KS 67218-1607 Denise.Maynard@va.gov Denise.Maynard@va.gov This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does no obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses.
Responses to this notice shall include:
1. Company Name
2. Address
3. Point of Contact
4. Phone, Fax, and Email
5. DUNS number
6. Must provide a capability statement that addresses the organizations qualifications and ability to perform the work in the Statement of Requirements.
See Attached:
1. Statement of Requirements
2. Gray Market Goods
Please respond whether you can or cannot provide.
All responses due by 10:00 am CST, Monday, May 13, 2019 Denise Maynard Contract Specialist denise.maynard @va.gov 913-946-1975 Network Contracting Office 15
See attached documents: Statement of Requirements Gray Market Goods
GRAY MARKET LANGUAGE
The Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system such that the OEM warranty and service are provided and maintained by the OEM. All warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. The vendor shall provide new items ONLY; no remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty.
STATEMENT OF WORK (SOW)
FOR
STERRAD 100NX STERILIZATION SYSTEM
VETERANS HEATH ADMINISTRATION
April 29, 2019
1. INTRODUCTION
This solicitation is to provide the Veterans Health Administration, Robert J. Dole Sterile Processing Department with one (1) Sterrad Sterilization System. This sterilization system sterilizes a wide variety of surgical instrumentation and up to two single channel flexible endoscopes at a time.
2. SCOPE OF WORK
The contractor shall provide all personnel, equipment, tools, materials, supervision, and non-personal services necessary to provide the sterilization system.
3. TECHNICAL REQUIREMENTS:
· One door configuration
· 208 V
· 60hz
· 3-phase
· 5 wire twist lock to a dedicated 30 amp, NEMA L21-30
4. ADDITIONAL SPECIFICATION:
· 4 Cycles: Standard, Flex, Express, Duo
· Cycle temperature: 47° – 56° C
· Uses Hydrogen peroxide sterilant
· Sterilant deliver in closed system. Cassettes with automatic expiration date detection.
· Automatic and touchless ejection of used cassette into a disposal container
· Gas plasma technology which breaks down H2O2 into safe elements of water and oxygen
· Maximum height: 70.9 inches
· Maximum width: 30.5 inches
· Maximum depth (single door): 41.5 inches
· Chamber dimensions: 17 x 21 x 29
· Minimum of 2 locking casters
· Weight not to exceed 385 kg
· User interface: touchscreen
5. DELIVERY & LOCATION INFORMATION
Delivery of the Sterrad 100NX Sterilization system will be shipped to:
| Robert J. Dole Medical Facility |
| Building 34 |
| 5500 East Kellogg |
| Wichita Kansas, 67218 |
File details come from the government source that posted it.