36C25024R0084 SF330 Request.pdf

PDF 129 KB Posted

Attached to
AE Install Canteen Vestibule Federal contract opportunity
Solicitation number
36C25024R0084
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This document is a presolicitation notice requesting SF330 submissions from qualified Architect/Engineer firms for the AE Install Canteen Vestibule project located at the VA Northern Indiana Health Care System in Marion, Indiana. Interested firms are requested to submit their SF330 forms by April 12, 2024 at 2:00pm local time to Jeffery Hairston at jeffery.hairston@va.gov. The project scope involves designing and providing 100% design services for the installation of a canteen vestibule, including a concrete patio with hydronic snow melting system. Selection criteria include professional qualifications, specialized experience, capacity, past performance, location, and experience in construction period services such as inspections, submittal reviews, and construction contract changes. Submissions must be electronic and sent to the specified contracting officer's email by the closing date and time.

View the file

Other files for this federal contract opportunity

Other files attached to AE Install Canteen Vestibule, newest first.
File Type Posted
36C25024R0084 SF330 Request.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice

*=Required Field Presolicitation Notice

SUBJECT* AE Install Canteen Vestibule 610-22-209 Request for SF 330s

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE* 46240

SOLICITATION NUMBER* 36C25024R0084

RESPONSE DATE/TIME/ZONE 04-12-2024 14:00 EASTERN TIME, NEW YORK,

USA

ARCHIVE 15 DAYS AFTER THE RESPONSE DATE

SET-ASIDE SDVOSBC

PRODUCT SERVICE CODE* C1DA

NAICS CODE* 541310

PLACE OF PERFORMANCE Northern IN VA Healthcare System

Marion Campus

1700 E. 38th St.

Marion IN

POSTAL CODE 46953

COUNTRY US

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS Department of Veterans Affairs

Network Contracting Office 10

8888 Keystone Crossing

Suite 1100

Indianapolis IN 46240

POINT OF CONTACT*

Contracting Officer

Jeffery Hairston jeffery.hairston@va.gov

DESCRIPTION

Request for SF 330s, AE Install Canteen Vestibule (Project 610-22-209)

The VA Northern Indiana Healthcare System, Marion Campus, is requesting SF 330 submissions from qualified Architect/Engineer (AE) Firms for the subject project. All interested firms are encouraged to submit SF 330s to Jeffery.hairston@va.gov by 2:00pm (local time) Friday, April 12, 2024. Please see below for information concerning this project, including the anticipated selection criteria.

1. Scope of Work

A. The Architect/Engineer (A/E) firm shall furnish professional services for 100% design to install canteen vestibule at VA Northern Indiana Health Care System, Marion Campus, 1700 E. 38th Street, Marion, IN 46953. The design will include Schematic Design, Design Development, Construction/Bid Documents per the A/E Design Submission Instructions Document, Construction Administration Services, Technical Specifications and Cost Estimates. The project: Install Canteen Vestibule shall be designed to accommodate the following functions based on the guides, manuals, and planning criteria:

1. Exterior door entrance at B-185 canteen location

1. Install vestibule with heated air curtain

ii. Concrete patio

1. Install new patio with hydronic snow melting system throughout the patio and sidewalk utilizing existing steam in B-185 basement.

B. The Schematic Design shall include a comprehensive study, inspection, and report of the existing project area conditions, which shall include HVAC, electrical, architectural components, plumbing, fire protection, asbestos, etc.

C. A/E shall provide a preliminary construction duration time for planning purposes. This information shall be communicated to all bidders for their review and inclusion within their bids. It shall be communicated within the bid documents that the contractor will be required to review and provide any concerns regarding the projected construction duration.

mailto:Jeffery.hairston@va.gov

D. A/E shall develop and provide schedules of equipment necessary to activate and operate the room/areas located in the project area.

E. A/E will be responsible for complete functional design and provide biddable documents meeting all the requirements. The VA Technical Information Library (TIL) available at http://www.cfm.va.gov/til/index.asp is managed by the VA Office of Construction and Facility Management. It is the master repository for all VA Numbered Standards for Construction to include design and construction specifications, procedures, standard details, BIM/CAD standards, equipment guides, space planning and design guides. The documents of the TIL shall be the minimum design criteria for all VA projects performed in the construction of new facilities and the modernization, alteration, addition, or improvement of its real property.

VA additionally through the documents on the TIL has adopted the latest edition of the following codes and standards (but not limited to):

1. Occupational, Safety and Health Administration (OSHA) Standards

2. International Building Code (IBC)

3. National Electrical Code (NEC)

4. NFPA 101 Life Safety Code

5. National Fire Protection Association (NFPA) Codes, except for NFPA 5000 and

NFPA 900

6. National Standard Plumbing Code (NSPC)

7. Safety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1

8. ASME Boiler and Pressure Vessel Code

9. ASME Code for Pressure Piping

10. International Plumbing Code (IPC)

11. Architectural Barriers Act Accessibility Standard (ABAAS) for Federal Facilities

12. Building Code Requirements for Reinforced Concrete, American Concrete Institute (ACI 318 – 2) and Commentary (ACI 318 – R2) http://www.cfm.va.gov/til/index.asp

13. Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)

14. Energy policy Act of 2005 (EPAct)Ventilation for Acceptable Indoor Air Quality – ASHRAE Standard 62.1

15. DOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low- Rise Residential Buildings, 10 CFR Parts 433, 434 and 435

16. Federal Leadership in High Performance and Sustainable Buildings:

Memorandum of Understanding (MOU)

17. Executive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management

18. The Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01010 of the VA Master Construction Specification

19. Ventilation for Acceptable Indoor Air Quality – ASHRAE Standard 62.1

20. Safety Standard for Refrigeration Systems – ASHRAE Standard 15

21. U.S. National CAD Standard

Where conflicts exist between VA adopted codes and standards and the documents on the TIL, the A/E shall bring this to the attention of the VA. The resolution of the conflict shall be made by the authority having jurisdiction for VA to ensure consistency department wide.

F. Designs for construction must produce a “complete and usable” facility or improvement when constructed. VA policy (VHA Office of Capital Assets Management, Engineering and Support memo Updated Construction Guidance and Expectations dated Sep 12, 2016) requires the A/E to certify that their design (including all bid alternates/bid deducts) is independent of any future construction project. In addition, the A/E must certify that it has produced a design that does not include furniture and equipment that will be procured separately unless directed otherwise by the VA. Equipment that can be part of the design includes those items to meet code requirements for building occupancy, items covered in the VA’s Master Construction Specifications (PG-18-1) Divisions 1 through 10, 13 through 26 or 28 through 48, non-IT equipment items covered by Division 27 and items covered by Division Numbers 12 31 00, 12 32 00, 12 34 00 and 12 36 00.

The A/E shall submit as part of the Final Bid Documents submittal a signed letter on company letterhead stating the design’s independence.

G. The project is to provide all necessary modifications and additions to VA NIHCS existing building structure, mechanical, electrical, and plumbing work.

H. A/E shall be responsible to review existing conditions to locations planned for development. Existing drawings of project: Install Canteen Vestibule on file at the VA NIHCS for review by the A/E. Access to files shall be coordinated with the COR.

I. All drawings shall adhere to VA project software requirements for Building Information Modeling (BIM) and Computer Aided Design (CAD) available at http://www.cfm.va.gov/til/projReq.asp. BIM software shall be Revit 2020 or the latest version available to VA NIHCS, Marion Campus.

The project BIM model minimum requirements shall be developed to include the systems described below as they would be built, the processes of installing them and to reflect record drawing conditions (possibly incorporating into the Marion VAMC Master Record Drawing – pending facility expertise). The deliverable model at the DD and CD design phases shall be developed to include as many of the systems described below (but not limited to) as are necessary and appropriate at that design phase.

Architectural/Interior Design

Square Footage/Volume including Room Names and Numbers

Departmental Ownership

(By Common Name, Capital Asset Inventory Department Definition and Strategic Capital Investment Program Department Definition)

Architectural Schedules

Walls and Curtain Wall Sizes, Shapes, and Material Data

Doors

Windows

Louvers

Roof

Floors

Ceilings http://www.cfm.va.gov/til/projReq.asp

Vertical Circulation

Architectural Specialties and Woodwork

Life Safety Information

(Fire Extinguishers, Wall Ratings, Door Ratings, Fire Protection/Alarms)

General Signage

Schedules

Furniture

Equipment

Structural

Foundations

Shafts and Pits

Mechanical

HVAC

Plumbing

Electrical/Telecommunications

Power and Lighting

Steam Distribution

Nurse Call System

Asbestos/ Hazard Material Info

Security System Information

(Access Controls, Security Cameras, Panic Alarms, Overhead Paging)

Exterior Building Information

Other Engineering Data as Required

Selection Criteria

Qualifications submitted by each firm for Project “610-22-209 Install Canteen Vestibule” will be reviewed and evaluated based on the following criteria:

(1) Professional qualifications necessary for satisfactory performance of required services;

(2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials;

(3) Capacity to accomplish the work in the required time;

(4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules;

(5) Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; and

(6) Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates.

Submittal Instructions.

a. Mailed or physical/hard copies will not be accepted.

b. All eligible, interested and capable contractors shall submit an electronic copy of their SF330s, via email, by the closing time/date of this announcement.

c. Send submissions to the contract specialist: Jeffery.hairston@VA.gov.

File details come from the government source that posted it. Updated .