Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| Security Measures for B143 Windows |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 45409-1337 |
| SOLICITATION NUMBER* |
| 36C25021Q1021 |
| RESPONSE DATE/TIME/ZONE |
| 09-09-2021 4PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| Z1GZ |
| NAICS CODE* |
| 236220 |
| PLACE OF PERFORMANCE |
| Department of Veterans Affairs |
Dayton VAMC
Bldg. 143
4100 West Third Street
Dayton OH
| POSTAL CODE |
| 45428 |
| COUNTRY |
| USA |
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office (NCO) 10 Dayton VA Medical Center 3140 Governor’s Place Blvd. Suite 210 Kettering OH 45409-1337
POINT OF CONTACT*
Contracting Officer Mary Jane Crim maryjane.crim@va.gov All Questions Shall be Sent VIA Email
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
STATEMENT OF WORK
1) Contract Title: Bldg. 143 Security Windows
2) Background:
The Office of Security and Law Enforcement guidelines and security measures for storage buildings and warehouses states that “Windows that are below 40’ from ground level or the roof of a lower abutment, or less than 7.5 m (25 ft.) from windows of an adjoining building, or accessible by a building ledge leading to windows of other floor rooms, security mesh screening for windows is required.”
3) Scope: Install security mesh screening for windows is required the outside of the first-floor windows and apply a frosted film to protect the equipment stored inside the warehouse from direct sunlight.
4) Specific:
1. All #304 stainless steel woven mesh 0.7 mm (.028 in.) wire diameter, with tensile strength of 15 kg/mm (800 pounds per linear inch).
2. Mesh 12x12 per 25 mm (1 in.) with main and sub frames of 2.7 mm (12 gauges) carbon steel with baked enamel finish and internal key locking slide bolts.
3. Applied tint will be frosted as to allow light to pass through but reduce the UV light that can damage stored equipment in the warehouse.
5) Performance Monitoring:
All work will be inspected by Engineering Staff at the Dayton VAMC before acceptance. All submittals will be sent to COR for approval prior to installation. No work outside the contract is to be done without written approval from the contracting officer.
6) Place of Performance
Dayton VA Medical Center 4100 W. 3rd St.
Building: 143 Dayton, OH 45428-9000
7) Period of Performance
To be completed within 90 business days from award of contract. It is understood that weather conditions may cause a delay of work. As such, any extensions must be reported to the POC and approved by the Contracting Officer.
8) Delivery Schedule
All work to be completed during normal working hours of 7:00 a.m. and 5:00 p.m. Monday-Friday excluding federal holidays.
| *=Required Field |