36C25021Q1021_Sol Notice.docx

DOCX document 25 KB Posted

Attached to
Z1GZ--Security Measures for B143 Windows Federal contract opportunity
Solicitation number
36C25021Q1021
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
Security Measures for B143 Windows

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
45409-1337
SOLICITATION NUMBER*
36C25021Q1021
RESPONSE DATE/TIME/ZONE
09-09-2021 4PM EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
Z1GZ
NAICS CODE*
236220
PLACE OF PERFORMANCE
Department of Veterans Affairs

Dayton VAMC

Bldg. 143

4100 West Third Street

Dayton OH

POSTAL CODE
45428
COUNTRY
USA

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office (NCO) 10 Dayton VA Medical Center 3140 Governor’s Place Blvd. Suite 210 Kettering OH 45409-1337

POINT OF CONTACT*

Contracting Officer Mary Jane Crim maryjane.crim@va.gov All Questions Shall be Sent VIA Email

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

STATEMENT OF WORK

1) Contract Title: Bldg. 143 Security Windows

2) Background:

The Office of Security and Law Enforcement guidelines and security measures for storage buildings and warehouses states that “Windows that are below 40’ from ground level or the roof of a lower abutment, or less than 7.5 m (25 ft.) from windows of an adjoining building, or accessible by a building ledge leading to windows of other floor rooms, security mesh screening for windows is required.”

3) Scope: Install security mesh screening for windows is required the outside of the first-floor windows and apply a frosted film to protect the equipment stored inside the warehouse from direct sunlight.

4) Specific:

1. All #304 stainless steel woven mesh 0.7 mm (.028 in.) wire diameter, with tensile strength of 15 kg/mm (800 pounds per linear inch).

2. Mesh 12x12 per 25 mm (1 in.) with main and sub frames of 2.7 mm (12 gauges) carbon steel with baked enamel finish and internal key locking slide bolts.

3. Applied tint will be frosted as to allow light to pass through but reduce the UV light that can damage stored equipment in the warehouse.

5) Performance Monitoring:

All work will be inspected by Engineering Staff at the Dayton VAMC before acceptance. All submittals will be sent to COR for approval prior to installation. No work outside the contract is to be done without written approval from the contracting officer.

6) Place of Performance

Dayton VA Medical Center 4100 W. 3rd St.

Building: 143 Dayton, OH 45428-9000

7) Period of Performance

To be completed within 90 business days from award of contract. It is understood that weather conditions may cause a delay of work. As such, any extensions must be reported to the POC and approved by the Contracting Officer.

8) Delivery Schedule

All work to be completed during normal working hours of 7:00 a.m. and 5:00 p.m. Monday-Friday excluding federal holidays.

*=Required Field
Presolicitation Notice

Presolicitation Notice

File details come from the government source that posted it. Updated .