FedBizOpps Sources Sought Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Sources Sought Notice Rev. March 2010 Startle Response/Tremor Monitor System 15212-5319 36C24E19Q0181 09-12-2019 N 334516 US Department of Veterans Affairs Veterans Health Administration Regional Procurement Office (RPO) East 323 North Shore Drive, Suite 500 Pittsburgh PA 15212-5319
RACHAEL.TALBOTT@VA.GOV
The VANJHCS Neurobehavioral Research Laboratory requires a Startle Response/Tremor Monitor System in order to execute a VA-ORD Shared Equipment Evaluation Program (ShEEP). The system will be used for measuring the rodent acoustic startle response and pre-pulse inhibition of the startle reflex. These are assessment techniques historically used by the researchers at the East Orange VA Medical Center (EOVAMC) to study the effects of stress on startle reactivity. These measurements are needed for ongoing research at the VANJHCS related to post-traumatic stress disorder (PTSD), traumatic brain injury (TBI) and Parkinson’s Disease (PD).
Startle Response/Tremor Monitor System characteristics as follows:
The VANJHCS requires a Startle Response/Tremor Monitor System. The system must include the following:
· 1 SR-LAB "ABS"/TREMOR MONITOR COMBO SYSTEM
· SR-LAB Control Software
· Tremor Control Software,
· One Test Station with “ABS” Cabinet
· SR-LAB Animal Enclosure
· (Small/Medium)
· Tremor Animal Enclosure
· USB Connection Chassis,
· User’s Manual
· Required cables and connectors.
· 5 SR-LAB "ABS"/TREMOR MONITOR COMBO SYSTEM – ADDITIONAL TEST STATION
· Tremor Animal Enclosure
· SR-LAB Animal Enclosure (Small/Medium)
· Cables and connectors
· 1 SR-LAB STANDARDIZATION UNIT
· 1 TREMOR STANDARDIZATION UNIT
· 6 SR-LAB LARGE ANIMAL ENCLOSURE, 8” (L) x 3.5” (ID)
· 6 POTENTIATED STARTLE KIT
· Shocker
· Shock Grid matched to enclosure size and cue light
· 6 SR-LAB SMALL/MEDIUM SHOCK GRID
· 6 SR-LAB LARGE SHOCK GRID
· 1 SHOCK LEVEL TESTER
· 1 PURE TONE AUDITORY SYSTEM (Up to 4 test stations)
· Software
· audio amplifier
· function generator
· all cables
· all connectors
· 1 PURE TONE AUDIO AMPLIFIER (Supports 4 Additional Test stations)
· 6 PURE TONE SPEAKER ASSEMBLY (PER TEST STATION)
· 6 AIR PUFF KIT - PER TEST STATION
· 1 AIR PUFF AIR MANIFOLD (MAX: 8 STATIONS)
· 1 SR-LAB TABLE SIX FOOT
· 1 CONFIGURED COMPUTER - ALL-IN-ONE DESKTOP
· High Performance All-In-One Touchscreen PC
· San Diego Instruments' SR-LAB Application Software and Drivers Pre-installed and Fully Tested
This is a Sources Sought synopsis only. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (large business, small business, 8(a), SDVOSB, etc.), relative to NAICS code 334516. Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. Based on responses to this synopsis, the Government may issue this RFQ as a Brand Name or Equal requirement in accordance with VAAR Clause 852.211-73 on eBuy or Fed Biz Ops. This notice is not a request for competitive proposals; however, any responsible source who believes it is capable of meeting the requirement and who is the Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller of all the items listed above, may submit a capability statement to the contracting office than no later than Thursday, September 12, 2019 4:00 PM EST. Interest/capability statements may be sent to Rachael Talbott Rachael.Talbott@va.gov. No telephone responses will be accepted. A determination not to compete the proposed requirement based upon the responses to this notice is solely within the discretion of the Government.